Literature DB >> 23371821

Inter- and intra-rater reliability of blood and cerebrospinal fluid flow quantification by phase-contrast MRI.

Inga Koerte1, Caroline Haberl, Michael Schmidt, Andreas Pomschar, Sang Lee, Petra Rapp, Denise Steffinger, Rong-Wen Tain, Noam Alperin, Birgit Ertl-Wagner.   

Abstract

PURPOSE: To evaluate the intra- and inter-rater reliability of the quantification of blood and CSF flow rates by phase contrast MRI.
MATERIALS AND METHODS: Blood and CSF flows in the upper cervical region were imaged with velocity-encoded cine-phase contrast using 3T scanners from different manufacturers at two centers. Data of 6 subjects scanned in center A and of 5 subjects in center B were analyzed by six readers at two levels of training. Each data set was analyzed three times in a randomized order for a total of 33 data sets. Intra-class correlation coefficients (ICC) were calculated for the primary measurements of areas and flow rates through the main cervical arteries, veins and the CSF space, and for secondary parameters derived from the individual flow rates.
RESULTS: ICC ranged from 0.80 to 0.96 for the lumen area and from 0.97 to 0.99 for the volumetric flow rate. The ICC for the derived secondary measures ranged from 0.85 to 0.99. Differences due to operator level of training were not statistically significant.
CONCLUSION: High intra- and inter-rater reliability of volumetric flow rate measurements is currently achievable across manufacturers and users' skill levels with a pulsatility based automated lumen segmentation.
Copyright © 2013 Wiley Periodicals, Inc., a Wiley company.

Entities:  

Keywords:  MR phase-contrast imaging; flow quantitation; inter-rater reliability; intra-rater reliability; pulsatility-based segmentation

Mesh:

Year:  2013        PMID: 23371821      PMCID: PMC3644311          DOI: 10.1002/jmri.24013

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  23 in total

Review 1.  Quantification in cardiac MRI.

Authors:  R J van der Geest; J H Reiber
Journal:  J Magn Reson Imaging       Date:  1999-11       Impact factor: 4.813

2.  Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging.

Authors:  Aart Spilt; Frieke M A Box; Rob J van der Geest; Johan H C Reiber; Patrik Kunz; Adriaan M Kamper; Gerard J Blauw; Mark A van Buchem
Journal:  J Magn Reson Imaging       Date:  2002-07       Impact factor: 4.813

3.  Phase contrast MRI quantification of pulsatile volumes of brain arteries, veins, and cerebrospinal fluids compartments: repeatability and physiological interactions.

Authors:  Anders Wåhlin; Khalid Ambarki; Jón Hauksson; Richard Birgander; Jan Malm; Anders Eklund
Journal:  J Magn Reson Imaging       Date:  2011-12-14       Impact factor: 4.813

4.  The measurement of time-averaged flow by magnetic resonance imaging using continuous acquisition in the carotid arteries and its comparison with Doppler ultrasound.

Authors:  M Tarnawski; S Padayachee; D J West; M J Graves; V T Ayton; M G Taylor; M A Smith
Journal:  Clin Phys Physiol Meas       Date:  1990-02

5.  Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: in vitro and in vivo validation.

Authors:  V S Lee; C E Spritzer; B A Carroll; L G Pool; M A Bernstein; S K Heinle; J R MacFall
Journal:  AJR Am J Roentgenol       Date:  1997-10       Impact factor: 3.959

6.  Measuring blood flow by nontriggered 2D phase-contrast MR angiography.

Authors:  C J Bakker; M J Hartkamp; W P Mali
Journal:  Magn Reson Imaging       Date:  1996       Impact factor: 2.546

7.  Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation.

Authors:  C J Bakker; M Kouwenhoven; M J Hartkamp; R M Hoogeveen; W P Mali
Journal:  Magn Reson Imaging       Date:  1995       Impact factor: 2.546

8.  Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example.

Authors:  M Eliasziw; S L Young; M G Woodbury; K Fryday-Field
Journal:  Phys Ther       Date:  1994-08

9.  MR-Intracranial pressure (ICP): a method to measure intracranial elastance and pressure noninvasively by means of MR imaging: baboon and human study.

Authors:  N J Alperin; S H Lee; F Loth; P B Raksin; T Lichtor
Journal:  Radiology       Date:  2000-12       Impact factor: 11.105

10.  Automated measurement of volume flow in the ascending aorta using MR velocity maps: evaluation of inter- and intraobserver variability in healthy volunteers.

Authors:  R J van der Geest; R A Niezen; E E van der Wall; A de Roos; J H Reiber
Journal:  J Comput Assist Tomogr       Date:  1998 Nov-Dec       Impact factor: 1.826

View more
  6 in total

1.  Automatic labeling of cerebral arteries in magnetic resonance angiography.

Authors:  Tora Dunås; Anders Wåhlin; Khalid Ambarki; Laleh Zarrinkoob; Richard Birgander; Jan Malm; Anders Eklund
Journal:  MAGMA       Date:  2015-12-08       Impact factor: 2.310

2.  Assessing test-retest reliability of phase contrast MRI for measuring cerebrospinal fluid and cerebral blood flow dynamics.

Authors:  Ashwin R Sakhare; Giuseppe Barisano; Judy Pa
Journal:  Magn Reson Med       Date:  2019-04-25       Impact factor: 3.737

3.  Effect of Atlas Vertebrae Realignment in Subjects with Migraine: An Observational Pilot Study.

Authors:  H Charles Woodfield; D Gordon Hasick; Werner J Becker; Marianne S Rose; James N Scott
Journal:  Biomed Res Int       Date:  2015-12-10       Impact factor: 3.411

4.  Reproducibility of pulmonary blood flow measurements by phase-contrast MRI using different 1.5 T MR scanners at two institutions.

Authors:  Rin Iraha; Nanae Tsuchiya; Tsuneo Yamashiro; Tae Iwasawa; Sadayuki Murayama
Journal:  Acta Radiol Open       Date:  2017-01-01

5.  Fast Phase-Contrast Cine MRI for Assessing Intracranial Hemodynamics and Cerebrospinal Fluid Dynamics.

Authors:  Naoki Ohno; Tosiaki Miyati; Tomohiro Noda; Noam Alperin; Takashi Hamaguchi; Masako Ohno; Tatsuhiko Matsushita; Mitsuhito Mase; Toshifumi Gabata; Satoshi Kobayashi
Journal:  Diagnostics (Basel)       Date:  2020-04-21

6.  In vitro evaluation of cerebrospinal fluid velocity measurement in type I Chiari malformation: repeatability, reproducibility, and agreement using 2D phase contrast and 4D flow MRI.

Authors:  Gwendolyn Williams; Suraj Thyagaraj; Audrey Fu; John Oshinski; Daniel Giese; Alexander C Bunck; Eleonora Fornari; Francesco Santini; Mark Luciano; Francis Loth; Bryn A Martin
Journal:  Fluids Barriers CNS       Date:  2021-03-18
  6 in total