Literature DB >> 9843231

Automated measurement of volume flow in the ascending aorta using MR velocity maps: evaluation of inter- and intraobserver variability in healthy volunteers.

R J van der Geest1, R A Niezen, E E van der Wall, A de Roos, J H Reiber.   

Abstract

PURPOSE: An automated contour detection algorithm was developed for the objective and reproducible quantitative analysis of velocity-encoded MR studies of the ascending aorta.
METHOD: The only user interaction required is the manual definition of a center point inside the cross-section of the aorta in one of the available images. The automated contour detection algorithm detects an initial model contour in this image and subsequently corrects for motion and deformation of the aortic cross-section in each of the acquired images over the complete cardiac cycle using dynamic programming techniques. Integrating the flow velocity values for each pixel within the detected contour results in an instantaneous flow value. Next, by integrating the instantaneous flow values for each acquired phase over the complete cardiac cycle, left ventricular stroke volume measurement could be obtained. The results of the automated method were compared with results derived from manually traced contours in MR studies from 11 healthy volunteers.
RESULTS: An excellent agreement in stroke volume measurements was observed: signed difference 0.61+/-1.15%. Inter- and intraobserver variabilities were <2% for both manual and automated image analysis methods. Manual tracing of contours required on the order of 10 min; the analysis time for automated contour detection was <6 s/study.
CONCLUSION: The present contour detection allows fast and reliable left ventricular stroke volume measurements from aortic flow studies using velocity-encoded MR studies in healthy volunteers. Further study is required to assess the accuracy and reproducibility of the algorithm in patients with aortic and aortic valve disease.

Entities:  

Mesh:

Year:  1998        PMID: 9843231     DOI: 10.1097/00004728-199811000-00013

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  47 in total

Review 1.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

2.  Quantitative cerebral blood flow in dynamic susceptibility contrast MRI using total cerebral flow from phase contrast magnetic resonance angiography.

Authors:  David Bonekamp; Mahaveer Degaonkar; Peter B Barker
Journal:  Magn Reson Med       Date:  2011-02-01       Impact factor: 4.668

3.  Rabbit models: ideal for imaging purposes?

Authors:  A van der Laarse; E E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2008-12-16       Impact factor: 2.357

4.  Echocardiography in Takotsubo cardiomyopathy; a useful approach?

Authors:  E E van der Wall; E R Holman; A J Scholte; J J Bax
Journal:  Int J Cardiovasc Imaging       Date:  2010-06       Impact factor: 2.357

5.  Mitral valve prolapse: a source of arrhythmias?

Authors:  E E van der Wall; M J Schalij
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

6.  Associations between total cerebral blood flow and age related changes of the brain.

Authors:  Adriaan C G M van Es; Jeroen van der Grond; V Hester ten Dam; Anton J M de Craen; Gerard J Blauw; Rudi G J Westendorp; Faiza Admiraal-Behloul; Mark A van Buchem
Journal:  PLoS One       Date:  2010-03-23       Impact factor: 3.240

7.  Tissue characterization in Takotsubo cardiomyopathy; a valuable approach?

Authors:  E E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

8.  Increased accuracy in computed tomography coronary angiography; a new body surface area adapted protocol.

Authors:  E E van der Wall; J E van Velzen; F R de Graaf; M M Boogers; J D Schuijf; J J Bax
Journal:  Int J Cardiovasc Imaging       Date:  2010-04-16       Impact factor: 2.357

9.  Cardiac magnetic resonance imaging in primary PCI: additional value?

Authors:  E E van der Wall; J J Bax; J W Jukema; M J Schalij
Journal:  Int J Cardiovasc Imaging       Date:  2009-05-26       Impact factor: 2.357

10.  Cardiovascular dynamics in ischemic cardiomyopathy during exercise.

Authors:  E E van der Wall; J J Bax; C A Swenne; P Steendijk; M J Schalij
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

View more