Literature DB >> 23359090

An interactive RADIANCE toolkit for customizable CT dose monitoring and reporting.

Tessa S Cook1, Anand Sundaram, William W Boonn, Woojin Kim.   

Abstract

The need for tools to monitor imaging-related radiation has grown dramatically in recent years. RADIANCE, a freely available open-source dose-monitoring tool, was developed in response to the need for an informatics solution in this realm. A number of open-source as well as commercial solutions have since been developed to enable radiology practices to monitor radiation dose parameters for modalities ranging from computed tomography to radiography to fluoroscopy. However, it is not sufficient to simply collect this data; it is equally important to be able to review it in the appropriate context. Most of the currently available dose-monitoring solutions have some type of reporting capability, such as a real-time dashboard or a static report. Previous versions of RADIANCE have included a real-time dashboard with pre-set screens that plot effective dose estimates according to different criteria, as well as monthly scorecards to summarize dose estimates for individuals within a radiology practice. In this work, we present the RADIANCE toolkit, a customizable reporting solution that allows users to generate reports of interest to them, summarizing a variety of metrics that can be grouped according to useful parameters. The output of the toolkit can be used for real-time dose monitoring or scheduled reporting, such as to a quality assurance committee. Making dose parameter data more accessible and more meaningful to the user promotes dose reduction efforts such as regular protocol review and optimization, and ultimately improves patient care by decreasing unnecessary radiation exposure.

Entities:  

Mesh:

Year:  2013        PMID: 23359090      PMCID: PMC3705013          DOI: 10.1007/s10278-013-9570-2

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  3 in total

1.  Nationwide trends in rates of utilization of noninvasive diagnostic imaging among the Medicare population between 1993 and 1999.

Authors:  Andrea J Maitino; David C Levin; Laurence Parker; Vijay M Rao; Jonathan H Sunshine
Journal:  Radiology       Date:  2003-04       Impact factor: 11.105

2.  RADIANCE: An automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates.

Authors:  Tessa S Cook; Stefan L Zimmerman; Scott R Steingall; Andrew D A Maidment; Woojin Kim; William W Boonn
Journal:  Radiographics       Date:  2011-10-03       Impact factor: 5.333

3.  Recent trends in utilization rates of abdominal imaging: the relative roles of radiologists and nonradiologist physicians.

Authors:  David C Levin; Vijay M Rao; Laurence Parker; Andrea J Frangos; Jonathan H Sunshine
Journal:  J Am Coll Radiol       Date:  2008-06       Impact factor: 5.532

  3 in total
  1 in total

1.  Patient dose management solution directly integrated in the RIS: "Gray Detector" software.

Authors:  A Nitrosi; A Corazza; M Bertolini; R Sghedoni; P Pattacini; M Iori
Journal:  J Digit Imaging       Date:  2014-12       Impact factor: 4.056

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.