| Literature DB >> 23349647 |
Bradley Pieters1, Hessel Wijkstra, Marcel van Herk, Ruud Kuipers, Emmie Kaljouw, Jean de la Rosette, Caro Koning.
Abstract
PURPOSE: To investigate the possibility of localization of intraprostatic lesions (IL) with contrast-enhanced ultrasound (CEUS) to support the brachytherapy treatment planning of temporary implants.Entities:
Keywords: brachytherapy planning; contrast-media; image-processing; prostate; ultrasonography
Year: 2012 PMID: 23349647 PMCID: PMC3552627 DOI: 10.5114/jcb.2012.29362
Source DB: PubMed Journal: J Contemp Brachytherapy ISSN: 2081-2841
Fig. 1Registered images of CEUS (A) and brachytherapy planning US (B) with delineated intraprostatic lesion
Fig. 2Brachytherapy isodose distribution without (1A) and with (1B) knowledge of the position of an intraprostatic lesion in the right peripheral zone. Note the coverage of the IL by the 140% isodose
Intraprostatic lesion (IL) characteristics
| median 35.9 ml | range 16.8-50.2 | |
| 1 | 4 | |
| 2 | 4 | |
| Yes | 6 | |
| No | 6 | |
| median 0.25 ml | range 0.04-0.53 | |
| median 0.09 ml | range 0.03-0.18 | |
| median 12.9 mm | range 6-18.1 | |
| median 8.5 mm | range 5.9-11.0 | |
Intraprostatic lesion (IL) mean dose-volume parameters for a non-adapted and adapted treatment plan
| Non-adapted | Adapted | |
|---|---|---|
| 67.7 | 92.7 | |
| 1.57 | 1.81 | |
| 66.0 | 95.7 | |
| 1.49 | 1.76 |
Mean dose-volume parameters and TRAK for a non-adapted and adapted treatment plan
| Non-adapted | Adapted |
| |
|---|---|---|---|
| 35.7 | 35.8 | 0.40 | |
| 13.7 | 14.2 | 0.61 | |
| 1.36 | 1.37 | 0.61 | |
| 0.84 | 0.88 | 0.08 | |
| 1.51 | 1.49 | 0.06 | |
| 459 | 473 | 0.09 |