Literature DB >> 23348202

Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection.

J J Vos1, A F Kalmar, M M R F Struys, J K G Wietasch, H G D Hendriks, T W L Scheeren.   

Abstract

BACKGROUND: Dynamic preload variables to predict fluid responsiveness are based either on the arterial pressure waveform (APW) or on the plethysmographic waveform (PW). We compared the ability of APW-based variations in stroke volume (SVV) and pulse pressure (PPV) and of PW-based plethysmographic variability index (PVI) to predict fluid responsiveness and to track fluid changes in patients undergoing major hepatic resection. Furthermore, we assessed whether the PPV/SVV ratio, as a measure of dynamic arterial elastance (Eadyn), could predict a reduction in norepinephrine requirement after fluid administration.
METHODS: Thirty patients received i.v. fluid (15 ml kg(-1) in 30 min) after hepatic resection and were considered responders when stroke volume index (SVI) increased ≥20% after fluid administration. SVV and SVI were measured by the FloTrac-Vigileo(®) device, and PVI was measured by the Masimo Radical 7 pulse co-oximeter(®).
RESULTS: The areas under a receiver operating characteristic curve for SVV, PPV, and PVI were 0.81, 0.77, and 0.78, respectively. In responders, all dynamic variables, except PVI, decreased after fluid administration. Eadyn predicted a reduced norepinephrine requirement (AUC = 0.81).
CONCLUSIONS: In patients undergoing major hepatic resection, both APW- and PW-based dynamic preload variables predict fluid responsiveness (preload) to a similar extent. Most variables (except PVI) also tracked fluid changes. Eadyn, as a measure of arterial elastance (afterload), might be helpful to distinguish the origin of hypotension. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT01060683.

Entities:  

Keywords:  arterial pressure; circulation; fluid therapy; measurement techniques; monitoring; cardiopulmonary

Mesh:

Substances:

Year:  2013        PMID: 23348202     DOI: 10.1093/bja/aes508

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  24 in total

Review 1.  Accuracy of pleth variability index to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis.

Authors:  Haitao Chu; Yong Wang; Yanfei Sun; Gang Wang
Journal:  J Clin Monit Comput       Date:  2015-08-05       Impact factor: 2.502

Review 2.  The relationship of perioperative fluid administration to outcomes in colorectal and pancreatic surgery: a review of the literature.

Authors:  Oliver S Eng; Laleh G Melstrom; Darren R Carpizo
Journal:  J Surg Oncol       Date:  2015-02-02       Impact factor: 3.454

3.  Accuracy of pulse oximeter perfusion index in thoracic epidural anesthesia under basal general anesthesia.

Authors:  Zifeng Xu; Jianhai Zhang; Yunfei Xia; Xiaoming Deng
Journal:  Int J Clin Exp Med       Date:  2014-07-15

4.  Prediction of fluid responsiveness in the beach chair position using dynamic preload indices.

Authors:  Su Hyun Lee; Yong-Min Chun; Young Jun Oh; Seokyung Shin; Sang Jun Park; Soo Young Kim; Yong Seon Choi
Journal:  J Clin Monit Comput       Date:  2015-12-31       Impact factor: 2.502

5.  Monitoring dynamic arterial elastance as a means of decreasing the duration of norepinephrine treatment in vasoplegic syndrome following cardiac surgery: a prospective, randomized trial.

Authors:  Pierre-Grégoire Guinot; Osama Abou-Arab; Mathieu Guilbart; Stéphane Bar; Elie Zogheib; Mona Daher; Patricia Besserve; Joseph Nader; Thierry Caus; Said Kamel; Hervé Dupont; Emmanuel Lorne
Journal:  Intensive Care Med       Date:  2017-01-24       Impact factor: 17.440

6.  Pleth variability index-directed fluid management in abdominal surgery under combined general and epidural anesthesia.

Authors:  Yinan Yu; Jing Dong; Zifeng Xu; Hao Shen; Jijian Zheng
Journal:  J Clin Monit Comput       Date:  2014-02-21       Impact factor: 2.502

Review 7.  Functional haemodynamic monitoring.

Authors:  Michael R Pinsky
Journal:  Curr Opin Crit Care       Date:  2014-06       Impact factor: 3.687

8.  Dynamic arterial elastance predicts mean arterial pressure decrease associated with decreasing norepinephrine dosage in septic shock.

Authors:  Pierre-Grégoire Guinot; Eugénie Bernard; Mélanie Levrard; Hervé Dupont; Emmanuel Lorne
Journal:  Crit Care       Date:  2015-01-19       Impact factor: 9.097

9.  The pleth variability index as an indicator of the central extracellular fluid volume in mechanically ventilated patients after anesthesia induction: comparison with initial distribution volume of glucose.

Authors:  Wenqing Lu; Jing Dong; Zifeng Xu; Hao Shen; Jijian Zheng
Journal:  Med Sci Monit       Date:  2014-03-08

10.  Noninvasive pulse pressure variation and stroke volume variation to predict fluid responsiveness at multiple thresholds: a prospective observational study.

Authors:  Jaap Jan Vos; Marieke Poterman; Pieternel Papineau Salm; Kai Van Amsterdam; Michel M R F Struys; Thomas W L Scheeren; Alain F Kalmar
Journal:  Can J Anaesth       Date:  2015-09-03       Impact factor: 5.063

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.