BACKGROUND: Dynamic preload variables to predict fluid responsiveness are based either on the arterial pressure waveform (APW) or on the plethysmographic waveform (PW). We compared the ability of APW-based variations in stroke volume (SVV) and pulse pressure (PPV) and of PW-based plethysmographic variability index (PVI) to predict fluid responsiveness and to track fluid changes in patients undergoing major hepatic resection. Furthermore, we assessed whether the PPV/SVV ratio, as a measure of dynamic arterial elastance (Eadyn), could predict a reduction in norepinephrine requirement after fluid administration. METHODS: Thirty patients received i.v. fluid (15 ml kg(-1) in 30 min) after hepatic resection and were considered responders when stroke volume index (SVI) increased ≥20% after fluid administration. SVV and SVI were measured by the FloTrac-Vigileo(®) device, and PVI was measured by the Masimo Radical 7 pulse co-oximeter(®). RESULTS: The areas under a receiver operating characteristic curve for SVV, PPV, and PVI were 0.81, 0.77, and 0.78, respectively. In responders, all dynamic variables, except PVI, decreased after fluid administration. Eadyn predicted a reduced norepinephrine requirement (AUC = 0.81). CONCLUSIONS: In patients undergoing major hepatic resection, both APW- and PW-based dynamic preload variables predict fluid responsiveness (preload) to a similar extent. Most variables (except PVI) also tracked fluid changes. Eadyn, as a measure of arterial elastance (afterload), might be helpful to distinguish the origin of hypotension. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT01060683.
BACKGROUND: Dynamic preload variables to predict fluid responsiveness are based either on the arterial pressure waveform (APW) or on the plethysmographic waveform (PW). We compared the ability of APW-based variations in stroke volume (SVV) and pulse pressure (PPV) and of PW-based plethysmographic variability index (PVI) to predict fluid responsiveness and to track fluid changes in patients undergoing major hepatic resection. Furthermore, we assessed whether the PPV/SVV ratio, as a measure of dynamic arterial elastance (Eadyn), could predict a reduction in norepinephrine requirement after fluid administration. METHODS: Thirty patients received i.v. fluid (15 ml kg(-1) in 30 min) after hepatic resection and were considered responders when stroke volume index (SVI) increased ≥20% after fluid administration. SVV and SVI were measured by the FloTrac-Vigileo(®) device, and PVI was measured by the Masimo Radical 7 pulse co-oximeter(®). RESULTS: The areas under a receiver operating characteristic curve for SVV, PPV, and PVI were 0.81, 0.77, and 0.78, respectively. In responders, all dynamic variables, except PVI, decreased after fluid administration. Eadyn predicted a reduced norepinephrine requirement (AUC = 0.81). CONCLUSIONS: In patients undergoing major hepatic resection, both APW- and PW-based dynamic preload variables predict fluid responsiveness (preload) to a similar extent. Most variables (except PVI) also tracked fluid changes. Eadyn, as a measure of arterial elastance (afterload), might be helpful to distinguish the origin of hypotension. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT01060683.
Authors: Su Hyun Lee; Yong-Min Chun; Young Jun Oh; Seokyung Shin; Sang Jun Park; Soo Young Kim; Yong Seon Choi Journal: J Clin Monit Comput Date: 2015-12-31 Impact factor: 2.502
Authors: Jaap Jan Vos; Marieke Poterman; Pieternel Papineau Salm; Kai Van Amsterdam; Michel M R F Struys; Thomas W L Scheeren; Alain F Kalmar Journal: Can J Anaesth Date: 2015-09-03 Impact factor: 5.063