Literature DB >> 23347297

A novel standardized bone model for thermal evaluation of bone osteotomies with various irrigation methods.

Georg D Strbac1, Katharina Giannis, Ewald Unger, Martina Mittlböck, Georg Watzek, Werner Zechner.   

Abstract

OBJECTIVES: Based on a novel standardized bovine specimen, the aim of this study was to investigate thermal effects of different irrigation methods during intermittent and graduated drilling.
MATERIAL AND METHODS: Temperature changes during implant osteotomies (n = 320) of 10 and 16 mm drilling depths with various irrigation methods were investigated on manufactured uniform bone samples providing homogenous cortical and cancellous areas and analogous thermal conductivity comparable to human bone. Automated sequences were performed with surgical twist drills of 2 mm ∅ and conical drills of 3.5, 4.3 and 5 mm ∅. Real-time recording of temperature increase was done using two custom-built multichannel thermoprobes with 14 temperature sensors at a predefined distance of 1 and 2 mm to the final osteotomy. The effects of drilling depth, drilling diameter and irrigation methods on temperature changes were investigated by a linear mixed model.
RESULTS: Using this uniform bone specimen, the greatest temperature rise was observed without any coolant supply with 29.87°C, followed by external with 28.47°C and then internal with 25.86°C and combined irrigation with 25.68°C. Significant differences (P ≤ 0.0156) between drill depths of 10 vs. 16 mm could be observed with all irrigation methods evaluated. With each of the irrigation methods, significantly higher temperature changes (P < 0.0001) during osteotomies could be observed between twist drills of 2 mm ∅ and conical drills of 3.5, 4.3 and 5 mm ∅. During 10 and 16 mm drilling osteotomies, external irrigation showed significantly higher temperatures (P < 0.05) for all conical drills compared with internal or combined irrigation, respectively. Significantly lower temperatures (P < 0.05) could be detected with internal or combined irrigation for the use of conical drills with various diameters and drilling depths.
CONCLUSIONS: This fully standardized bone model provides optimized comparability for the evaluation of bone osteotomies and resulting temperature changes. As regards the efficiency of the various irrigation methods, it could be demonstrated that internal and combined irrigation appears to be more beneficial than external irrigation.
© 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

Entities:  

Keywords:  combined irrigation; dental implants; external irrigation; heat generation; implant drills; implant osteotomies; internal irrigation; multiple temperature sensors; standardized testing specimen; thermal osteonecrosis

Mesh:

Substances:

Year:  2013        PMID: 23347297     DOI: 10.1111/clr.12090

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  11 in total

1.  Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.

Authors:  R A Delgado-Ruiz; E Velasco Ortega; G E Romanos; S Gerhke; I Newen; J L Calvo-Guirado
Journal:  Clin Oral Investig       Date:  2017-04-22       Impact factor: 3.573

2.  Comparison of Maximum Heat Generation during Implant Site Preparation between Single and Gradual Drilling Protocols in Artificial D1 Bone Blocks: An In Vitro Study.

Authors:  Tammam Koutiech; Omar Ahmad Heshmeh; Kamal Alkerdi; Johnny Toumi; Laith Al Sabek
Journal:  Int J Dent       Date:  2022-06-18

3.  Influence of bone density and implant drill diameter on the resulting axial force and temperature development in implant burs and artificial bone: an in vitro study.

Authors:  Stephan Christian Möhlhenrich; Mustapha Abouridouane; Nicole Heussen; Ali Modabber; Fritz Klocke; Frank Hölzle
Journal:  Oral Maxillofac Surg       Date:  2015-11-20

Review 4.  Low-speed drilling without irrigation versus conventional drilling for dental implant osteotomy preparation: a systematic review.

Authors:  Juan Carlos Bernabeu-Mira; David Soto-Peñaloza; Miguel Peñarrocha-Diago; Fabio Camacho-Alonso; Rebeca Rivas-Ballester; David Peñarrocha-Oltra
Journal:  Clin Oral Investig       Date:  2021-04-24       Impact factor: 3.573

Review 5.  Heat Development During Medical Drilling: Influencing Factors and Examination Methods - Overview and First Results.

Authors:  Ole Jung; Carolin Lindner; Sven Pantermehl; Mike Barbeck
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

6.  In Vitro Study on Bone Heating during Drilling of the Implant Site: Material, Design and Wear of the Surgical Drill.

Authors:  Juan Carlos Bernabeu-Mira; Hilario Pellicer-Chover; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  Materials (Basel)       Date:  2020-04-19       Impact factor: 3.623

7.  An experimental comparative study of drilling efficiency and temperature elevation with unmodified and modified medical drills in pig tibia bone.

Authors:  Makoto Enokida; Haruhisa Kanaya; Kazutake Uehara; Masaru Ueki; Hideki Nagashima
Journal:  Heliyon       Date:  2019-08-02

8.  Influence of Drilling Technique on the Radiographic, Thermographic, and Geomorphometric Effects of Dental Implant Drills and Osteotomy Site Preparations.

Authors:  Lara Fraguas de San José; Filippo Maria Ruggeri; Roberta Rucco; Álvaro Zubizarreta-Macho; Jorge Alonso Pérez-Barquero; Elena Riad Deglow; Sofía Hernández Montero
Journal:  J Clin Med       Date:  2020-11-11       Impact factor: 4.241

9.  Temperature Values Variability in Piezoelectric Implant Site Preparation: Differences between Cortical and Corticocancellous Bovine Bone.

Authors:  Luca Lamazza; Girolamo Garreffa; Domenica Laurito; Marco Lollobrigida; Luigi Palmieri; Alberto De Biase
Journal:  Biomed Res Int       Date:  2016-03-24       Impact factor: 3.411

10.  Comparison of peri-implant bone loss between conventional drilling with irrigation versus low-speed drilling without irrigation.

Authors:  H Pellicer-Chover; D Peñarrocha-Oltra; A Aloy-Prosper; J-C Sanchis-Gonzalez; M-A Peñarrocha-Diago; M Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-11-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.