Five-year long-term clinical follow-up of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery disease: the SPIRIT II trial.

Yoshinobu Onuma1, Karine Miquel-Hebert, Patrick W Serruys.   

Abstract

AIMS: To assess the safety and performance of the XIENCE V everolimus-eluting stent (EES) versus the TAXUS paclitaxel-eluting stent (PES) in the treatment of patients with de novo coronary artery lesions after a five-year follow-up period. Second-generation drug-eluting stents (DES) were developed with the aim of improving the safety profile of DES, after reports of stent thrombosis (ST) with first-generation devices. However, long-term follow-up data are scarce. METHODS AND
RESULTS: SPIRIT II was a multicentre, prospective, single-blind, clinical trial, randomising 300 patients with up to two de novo coronary artery lesions in a ratio of 3:1 to either a EES or a PES. The five-year clinical follow-up was completed in 244 patients (81%). At five-year follow-up, 19.5% of patients were on thienopyridine in the EES arm, while 30.5% were on the same therapy in the PES arm. Cardiac mortality was significantly lower in EES than in PES (1.5% vs. 7.3%, p=0.015). There was a trend towards lower cardiac death and MI (4.8% vs. 11.4%) and lower ID-TLR (4.7% vs. 9.4%) in EES than in PES. As a result, there was a consistent reduction in ID-MACE for EES vs. PES (ID-MACE 8.0% vs. 18.1%, p=0.018). In addition, the ARC-defined stent thrombosis rate was numerically lower in EES compared to PES (0.9% vs. 2.8%). No definite stent thrombosis events were observed after two years in the EES arm.
CONCLUSIONS: Five-year clinical follow-up of the SPIRIT II trial demonstrated the continuing long-term safety and efficacy of EES.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23339811     DOI: 10.4244/EIJV8I9A161

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  11 in total

1.  Comparison of the vessel healing process after everolimus-eluting stent and bare metal stent implantations in patients with ST-elevation myocardial infarction.

Authors:  Hideki Yano; Shigeo Horinaka; Manami Watahik; Tomoko Watanabe; Toshihiko Ishimitsu
Journal:  Heart Vessels       Date:  2018-11-03       Impact factor: 2.037

2.  The efficacy of everolimus-eluting stent implantation in patients with ST-segment elevation myocardial infarction: outcomes of 2-year clinical follow-up.

Authors:  Hideki Yano; Shigeo Horinaka; Mayuko Ishikawa; Toshihiko Ishimitsu
Journal:  Heart Vessels       Date:  2015-12-19       Impact factor: 2.037

Review 3.  New-Generation Coronary Stents: Current Data and Future Directions.

Authors:  Ankur Kalra; Hasan Rehman; Sahil Khera; Braghadheeswar Thyagarajan; Deepak L Bhatt; Neal S Kleiman; Robert W Yeh
Journal:  Curr Atheroscler Rep       Date:  2017-03       Impact factor: 5.113

4.  First-generation versus second-generation drug-eluting stents in current clinical practice: updated evidence from a comprehensive meta-analysis of randomised clinical trials comprising 31 379 patients.

Authors:  Eliano Pio Navarese; Mariusz Kowalewski; David Kandzari; Alexandra Lansky; Bartosz Górny; Lukasz Kołtowski; Ron Waksman; Sergio Berti; Giuseppe Musumeci; Ugo Limbruno; Rene J van der Schaaf; Malte Kelm; Jacek Kubica; Harry Suryapranata
Journal:  Open Heart       Date:  2014-08-21

Review 5.  Long-term clinical outcomes of everolimus-eluting stent versus paclitaxel-eluting stent in patients undergoing percutaneous coronary interventions: a meta-analysis.

Authors:  Min Meng; Bei Gao; Xia Wang; Zheng-gang Bai; Ri-Na Sa; Bin Ge
Journal:  BMC Cardiovasc Disord       Date:  2016-02-09       Impact factor: 2.298

Review 6.  Everolimus-eluting stent platforms in percutaneous coronary intervention: comparative effectiveness and outcomes.

Authors:  Vasileios F Panoulas; Ioannis Mastoris; Klio Konstantinou; Maurizio Tespili; Alfonso Ielasi
Journal:  Med Devices (Auckl)       Date:  2015-07-24

7.  Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis.

Authors:  Eliano P Navarese; Kenneth Tandjung; Bimmer Claessen; Felicita Andreotti; Mariusz Kowalewski; David E Kandzari; Dean J Kereiakes; Ron Waksman; Laura Mauri; Ian T Meredith; Aloke V Finn; Hyo-Soo Kim; Jacek Kubica; Harry Suryapranata; Toni Mustahsani Aprami; Giuseppe Di Pasquale; Clemens von Birgelen; Elvin Kedhi
Journal:  BMJ       Date:  2013-11-06

8.  Histopathological Comparison among Biolimus, Zotarolimus and Everolimus-Eluting Stents in Porcine Coronary Restenosis Model.

Authors:  Kyung Seob Lim; Myung Ho Jeong; In Ho Bae; Dae Sung Park; Jong Min Kim; Jung Ha Kim; Dong Lyun Cho; Doo Sun Sim; Keun-Ho Park; Young Joon Hong; Youngkeun Ahn
Journal:  Korean Circ J       Date:  2013-11-30       Impact factor: 3.243

9.  Serial changes of neointimal tissue after everolimus-eluting stent implantation in porcine coronary artery: an optical coherence tomography analysis.

Authors:  Hoyoun Won; Jung-Sun Kim; Dong-Ho Shin; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Biomed Res Int       Date:  2014-09-18       Impact factor: 3.411

10.  Predictive Ability of the SYNergy Between Percutaneous Coronary Intervention with TAXus and Cardiac Surgery Score II for Long-term Mortality in Patients with Three-vessel Coronary Artery Disease Undergoing Percutaneous Coronary Intervention Treated with Second-generation Drug-eluting Stents.

Authors:  Ji-Qiang He; Xian-Peng Yu; Cheng Peng; Quan Li; Ya-Wei Luo; Yue-Chun Gao; Xiao-Ling Zhang; Chang-Yan Wu; Hua Zhao; Yu-Chen Zhang; Jing-Hua Liu; Shu-Zheng Lyu; Fang Chen
Journal:  Chin Med J (Engl)       Date:  2015-08-20       Impact factor: 2.628

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.