Mimoza Canga1, Vito Antonio Malagnino2, Rosela Rroco3, Lindita Xhemnica3, Rozarka Budina3, Hava Çelaj4, Rezarta Kurti5. 1. Faculty of Public Health, "Ismail Qemali" University Vlore, Albania. 2. Endodontic Chair, University "Gabriele D'Annunzio" Chiety, Italy. 3. Faculty of Dental Medicine, Medical University of Tirana, Albania. 4. University Hospital Center "Mother Teresa", Tirana, Albania. 5. Private Medical Services, Vlore, Albania.
Abstract
Objective:The aim of the present study was to evaluate maintenance of the original anatomy of the root canal diameters instrumented with the Mtwo rotary instruments and BioRace file systems. Material and method:Acrylic resin blocks with 160 simulated root canals with an angle curvature 15°-30° were taken into consideration in the present comparative study. The 160 simulated root canals were divided into two groups, each of them containing 80 acrylic resin blocks. Each group was divided into two subgroups (n=40 canals each). The simulated root canals subgroups were prepared with Mtwo and BioRace rotary nickel-titanium instruments. The results were scrutinized using analysis of variance (ANOVA)-test and Tukey's test. The significance level was set at P < 0.05. Results: No significant difference was noted between the Mtwo rotary instruments and BioRace files as they both had equal value in the coronal section (P=.000) in S1 (D1) and S1 (Dpi). The results of Tukey's test revealed a significant difference between the Mtwo rotary instruments and BioRace files in middle and apical section with the value (P=.003) in S3 (Dpi) and S4 (Dpi). The results of Tukey's test found out a significant difference between the Mtwo rotary instruments and BioRace files in the middle and apical section with the respective values (P=.003) in S3 (Ai) and (P=.006) in S4 (Ai). Conclusion: Ccording to the findings of the present study, enlargement of the root canal diameters resulted to be better on the middle and apical section of the canal prepared with Mtwo instruments in comparison with BioRace instruments. Thus, Mtwo instruments will increase the rate of success of endodontic therapy.
Objective:The aim of the present study was to evaluate maintenance of the original anatomy of the root canal diameters instrumented with the Mtwo rotary instruments and BioRace file systems. Material and method:Acrylic resin blocks with 160 simulated root canals with an angle curvature 15°-30° were taken into consideration in the present comparative study. The 160 simulated root canals were divided into two groups, each of them containing 80 acrylic resin blocks. Each group was divided into two subgroups (n=40 canals each). The simulated root canals subgroups were prepared with Mtwo and BioRace rotary nickel-titanium instruments. The results were scrutinized using analysis of variance (ANOVA)-test and Tukey's test. The significance level was set at P < 0.05. Results: No significant difference was noted between the Mtwo rotary instruments and BioRace files as they both had equal value in the coronal section (P=.000) in S1 (D1) and S1 (Dpi). The results of Tukey's test revealed a significant difference between the Mtwo rotary instruments and BioRace files in middle and apical section with the value (P=.003) in S3 (Dpi) and S4 (Dpi). The results of Tukey's test found out a significant difference between the Mtwo rotary instruments and BioRace files in the middle and apical section with the respective values (P=.003) in S3 (Ai) and (P=.006) in S4 (Ai). Conclusion: Ccording to the findings of the present study, enlargement of the root canal diameters resulted to be better on the middle and apical section of the canal prepared with Mtwo instruments in comparison with BioRace instruments. Thus, Mtwo instruments will increase the rate of success of endodontic therapy.
Authors: Josué Martos; Gustavo Henrique Tatsch; Augusto César Tatsch; Luiz Fernando Machado Silveira; Carmen María Ferrer-Luque Journal: Anat Sci Int Date: 2011-03-17 Impact factor: 1.741
Authors: Gopal S Narayan; Sokkalingam Mothilal Venkatesan; C S Karumaran; Rajamani Indira; S Ramachandran; M R Srinivasan Journal: Contemp Clin Dent Date: 2012-09
Authors: Iussif Mamede-Neto; Alvaro Henrique Borges; Orlando Aguirre Guedes; Durvalino de Oliveira; Fábio Luis Miranda Pedro; Carlos Estrela Journal: Open Dent J Date: 2017-02-14