Literature DB >> 23307128

A microfluidic electrochemiluminescent device for detecting cancer biomarker proteins.

Naimish P Sardesai1, Karteek Kadimisetty, Ronaldo Faria, James F Rusling.   

Abstract

We describe an electrochemiluminescence (ECL) immunoarray incorporated into a prototype microfluidic device for highly sensitive protein detection and apply this system to accurate, sensitive measurements of prostate-specific antigen (PSA) and interleukin-6 (IL-6) in serum. The microfluidic system employed three molded polydimethylsiloxane (PDMS) channels on a conductive pyrolytic graphite chip (2.5 × 2.5 cm) inserted into a machined chamber and interfaced with a pump, switching valve, and sample injector. Each of the three PDMS channels encompasses three 3 μL analytical wells. Capture-antibody-decorated single-wall carbon nanotube forests are fabricated in the bottom of the wells. The antigen is captured by these antibodies on the well bottoms. Then, a RuBPY-silica-secondary antibody (Ab2) label is injected to bind to antigen on the array, followed by injection of sacrificial reductant tripropylamine (TPrA) to produce ECL. For detection, the chip is placed into an open-top ECL measuring cell, and the channels are in contact with electrolyte in the chamber. Potential applied at 0.95 V versus Ag/AgCl oxidizes TPrA to produce ECL by redox cycling the RuBPY species in the particles, and ECL light is measured by a charge-coupled device camera. This approach achieved ultralow detection limits of 100 fg mL(-1) for PSA (9 zeptomole) and 10 fg mL(-1) (1 zeptomole) for IL-6 in calf serum, a 10-25-fold improvement of a similar non-microfluidic array. PSA and IL-6 in synthetic cancer patient serum samples were detected in 1.1 h and results correlated well with single-protein enzyme-linked immunosorbent assays.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23307128      PMCID: PMC3610849          DOI: 10.1007/s00216-012-6656-5

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  46 in total

Review 1.  Electrochemiluminescence (ECL).

Authors:  Mark M Richter
Journal:  Chem Rev       Date:  2004-06       Impact factor: 60.622

Review 2.  Immunoassays in microfluidic systems.

Authors:  Alphonsus H C Ng; Uvaraj Uddayasankar; Aaron R Wheeler
Journal:  Anal Bioanal Chem       Date:  2010-04-27       Impact factor: 4.142

Review 3.  Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer.

Authors:  James F Rusling; Challa V Kumar; J Silvio Gutkind; Vyomesh Patel
Journal:  Analyst       Date:  2010-07-08       Impact factor: 4.616

4.  Millimeter-scale contact printing of aqueous solutions using a stamp made out of paper and tape.

Authors:  Chao-Min Cheng; Aaron D Mazzeo; Jinlong Gong; Andres W Martinez; Scott T Phillips; Nina Jain; George M Whitesides
Journal:  Lab Chip       Date:  2010-10-15       Impact factor: 6.799

Review 5.  Biosensor developments: application to prostate-specific antigen detection.

Authors:  Declan A Healy; Conor J Hayes; Paul Leonard; Louise McKenna; Richard O'Kennedy
Journal:  Trends Biotechnol       Date:  2007-01-24       Impact factor: 19.536

Review 6.  Electrogenerated chemiluminescence and its biorelated applications.

Authors:  Wujian Miao
Journal:  Chem Rev       Date:  2008-05-28       Impact factor: 60.622

Review 7.  Capillary electrophoresis based immunoassays: a critical review.

Authors:  D Schmalzing; W Nashabeh
Journal:  Electrophoresis       Date:  1997-11       Impact factor: 3.535

8.  Carbon nanotube microwell array for sensitive electrochemiluminescent detection of cancer biomarker proteins.

Authors:  Naimish P Sardesai; John C Barron; James F Rusling
Journal:  Anal Chem       Date:  2011-07-29       Impact factor: 6.986

Review 9.  Proteomic applications for the early detection of cancer.

Authors:  Julia D Wulfkuhle; Lance A Liotta; Emanuel F Petricoin
Journal:  Nat Rev Cancer       Date:  2003-04       Impact factor: 60.716

10.  Ultrasensitive detection of cancer biomarkers in the clinic by use of a nanostructured microfluidic array.

Authors:  Ruchika Malhotra; Vyomesh Patel; Bhaskara V Chikkaveeraiah; Bernard S Munge; Sok Ching Cheong; Rosnah B Zain; Mannil T Abraham; Dipak K Dey; J Silvio Gutkind; James F Rusling
Journal:  Anal Chem       Date:  2012-07-03       Impact factor: 6.986

View more
  23 in total

1.  Suspended microfluidics.

Authors:  Benjamin P Casavant; Erwin Berthier; Ashleigh B Theberge; Jean Berthier; Sara I Montanez-Sauri; Lauren L Bischel; Kenneth Brakke; Curtis J Hedman; Wade Bushman; Nancy P Keller; David J Beebe
Journal:  Proc Natl Acad Sci U S A       Date:  2013-05-31       Impact factor: 11.205

Review 2.  Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.

Authors:  Sharma T Sanjay; Guanglei Fu; Maowei Dou; Feng Xu; Rutao Liu; Hao Qi; XiuJun Li
Journal:  Analyst       Date:  2015-11-07       Impact factor: 4.616

Review 3.  Biomolecular engineering for nanobio/bionanotechnology.

Authors:  Teruyuki Nagamune
Journal:  Nano Converg       Date:  2017-04-24

4.  High-throughput metabolic genotoxicity screening with a fluidic microwell chip and electrochemiluminescence.

Authors:  Dhanuka P Wasalathanthri; Spundana Malla; Itti Bist; Chi K Tang; Ronaldo C Faria; James F Rusling
Journal:  Lab Chip       Date:  2013-12-07       Impact factor: 6.799

5.  Automated multiplexed ECL Immunoarrays for cancer biomarker proteins.

Authors:  Karteek Kadimisetty; Spundana Malla; Naimish P Sardesai; Amit A Joshi; Ronaldo C Faria; Norman H Lee; James F Rusling
Journal:  Anal Chem       Date:  2015-04-09       Impact factor: 6.986

6.  On-Chip Fluorescent Labeling using Reversed-phase Monoliths and Microchip Electrophoretic Separations of Selected Preterm Birth Biomarkers.

Authors:  Mukul Sonker; Rui Yang; Vishal Sahore; Suresh Kumar; Adam T Woolley
Journal:  Anal Methods       Date:  2016-09-30       Impact factor: 2.896

7.  Nanomaterials and biomaterials in electrochemical arrays for protein detection.

Authors:  James F Rusling; Gregory W Bishop; Nhi Doan; Fotios Papadimitrakopoulos
Journal:  J Mater Chem B       Date:  2014-01-07       Impact factor: 6.331

8.  Electrochemiluminescence at Bare and DNA-Coated Graphite Electrodes in 3D-Printed Fluidic Devices.

Authors:  Gregory W Bishop; Jennifer E Satterwhite-Warden; Itti Bist; Eric Chen; James F Rusling
Journal:  ACS Sens       Date:  2015-12-17       Impact factor: 7.711

9.  3D-printed supercapacitor-powered electrochemiluminescent protein immunoarray.

Authors:  Karteek Kadimisetty; Islam M Mosa; Spundana Malla; Jennifer E Satterwhite-Warden; Tyler M Kuhns; Ronaldo C Faria; Norman H Lee; James F Rusling
Journal:  Biosens Bioelectron       Date:  2015-09-11       Impact factor: 10.618

10.  Automated 3D-Printed Microfluidic Array for Rapid Nanomaterial-Enhanced Detection of Multiple Proteins.

Authors:  Karteek Kadimisetty; Spundana Malla; Ketki S Bhalerao; Islam M Mosa; Snehasis Bhakta; Norman H Lee; James F Rusling
Journal:  Anal Chem       Date:  2018-05-31       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.