Literature DB >> 23301204

Comparison of conventional lateral cephalograms with corresponding CBCT radiographs.

Chang-Seo Park1, Jae-Kyu Park, Huijun Kim, Sang-Sun Han, Ho-Gul Jeong, Hyok Park.   

Abstract

PURPOSE: This study was performed to assess the compatibility of cone beam computed tomography (CBCT) synthesized cephalograms with conventional cephalograms, and to find a method for obtaining normative values for three-dimensional (3D) assessments.
MATERIALS AND METHODS: The sample group consisted of 10 adults with normal occlusion and well-balanced faces. They were imaged using conventional and CBCT cephalograms. The CBCT cephalograms were synthesized from the CBCT data using OnDemand 3D software. Twenty-one angular and 12 linear measurements from each imaging modality were compared and analyzed using paired-t test.
RESULTS: The linear measurements between the two imaging modalities were not statistically different (p>0.05) except for the U1 to facial plane distance. The angular measurements between the two imaging modalities were not statistically different (p>0.05) with the exception of the gonial angle, ANB difference, and facial convexity.
CONCLUSION: Two-dimensional cephalometric norms could be readily used for 3D quantitative assessment, if corrected for lateral cephalogram distortion.

Entities:  

Keywords:  Cephalometry; Cone-Beam Computed Tomography

Year:  2012        PMID: 23301204      PMCID: PMC3534172          DOI: 10.5624/isd.2012.42.4.201

Source DB:  PubMed          Journal:  Imaging Sci Dent        ISSN: 2233-7822


  10 in total

1.  A method for correction of radiographic errors in serial three-dimensional cephalometry.

Authors:  M M Rousset; F Simonek; J P Dubus
Journal:  Dentomaxillofac Radiol       Date:  2003-01       Impact factor: 2.419

2.  Comparison of linear and angular measurements using two-dimensional conventional methods and three-dimensional cone beam CT images reconstructed from a volumetric rendering program in vivo.

Authors:  U Oz; K Orhan; N Abe
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

3.  A comparison of craniofacial morphology in patients with and without facial asymmetry--a three-dimensional analysis with computed tomography.

Authors:  T-G Kwon; H-S Park; H-M Ryoo; S-H Lee
Journal:  Int J Oral Maxillofac Surg       Date:  2005-05-31       Impact factor: 2.789

4.  Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography.

Authors:  Allan G Farman; William C Scarfe
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-08       Impact factor: 2.650

5.  Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgery.

Authors:  Lucia H S Cevidanes; L'Tanya J Bailey; Scott F Tucker; Martin A Styner; Andre Mol; Ceib L Phillips; William R Proffit; Timothy Turvey
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-01       Impact factor: 2.650

6.  Comparison between conventional and cone-beam computed tomography-generated cephalograms.

Authors:  Paolo M Cattaneo; Christian Borgkvist Bloch; Dorte Calmar; Mette Hjortshøj; Birte Melsen
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-12       Impact factor: 2.650

7.  The reliability of head film measurements. 1. Landmark identification.

Authors:  S Baumrind; R C Frantz
Journal:  Am J Orthod       Date:  1971-08

8.  In vivo comparison of conventional and cone beam CT synthesized cephalograms.

Authors:  Vandana Kumar; John Ludlow; Lucia Helena Soares Cevidanes; André Mol
Journal:  Angle Orthod       Date:  2008-09       Impact factor: 2.079

9.  From 2D to 3D: an algorithm to derive normal values for 3-dimensional computerized assessment.

Authors:  Bruno Frazäo Gribel; Marcos Nadler Gribel; Flavio Ricardo Manzi; Sharon L Brooks; James A McNamara
Journal:  Angle Orthod       Date:  2011-01       Impact factor: 2.079

10.  Cephalometric measurements from 3D reconstructed images compared with conventional 2D images.

Authors:  Natalia Zamora; Jose M Llamas; Rosa Cibrián; Jose L Gandia; Vanessa Paredes
Journal:  Angle Orthod       Date:  2011-04-07       Impact factor: 2.079

  10 in total
  7 in total

1.  Accuracy of 3D cephalometric measurements based on an automatic knowledge-based landmark detection algorithm.

Authors:  Abhishek Gupta; Om Prakash Kharbanda; Viren Sardana; Rajiv Balachandran; Harish Kumar Sardana
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-12-24       Impact factor: 2.924

2.  Comparison of linear measurements between CBCT orthogonally synthesized cephalograms and conventional cephalograms.

Authors:  S Yang; D G Liu; Y Gu
Journal:  Dentomaxillofac Radiol       Date:  2014-07-16       Impact factor: 2.419

3.  [Cone-beam computed tomography-synthesized cephalograms for evaluating the vertical dimension of occlusions].

Authors:  Ya-Nan Wei; Zhi-Yun Cao; Gang Li; Xun Sheng; Yi-Qing Xiong; Wei Li
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2019-02-01

4.  Cephalometric Norms in an Omani Adult Population of Arab Descent.

Authors:  Prashantha S Govinakovi; Ibrahim Al-Busaidi; Viswapurna Senguttuvan
Journal:  Sultan Qaboos Univ Med J       Date:  2018-09-09

5.  The Accuracy of Lateral Cephalogram in Representing the Anterior Maxillary Dentoalveolar Position.

Authors:  Supontep Teerakanok; Chairat Charoemratrote; Pannapat Chanmanee
Journal:  Diagnostics (Basel)       Date:  2022-07-30

6.  Three-Dimensional Analysis of Posterior Mandibular Displacement in Rats.

Authors:  Ioannis Lyros; Efstratios Ferdianakis; Demetrios Halazonetis; Theodoros Lykogeorgos; Antigoni Alexiou; Konstantina-Eleni Alexiou; Maria Georgaki; Emmanouil Vardas; Zafeiroula Yfanti; Apostolos I Tsolakis
Journal:  Vet Sci       Date:  2022-03-20

7.  Three-Dimensional Digital Image Analysis of Skeletal and Soft Tissue Points A and B after Orthodontic Treatment with Premolar Extraction in Bimaxillary Protrusive Patients.

Authors:  You Na Lim; Byoung-Eun Yang; Soo-Hwan Byun; Sang-Min Yi; Sung-Woon On; In-Young Park
Journal:  Biology (Basel)       Date:  2022-02-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.