Literature DB >> 23292887

Is diagrammatic goniometry feasible for finger ROM evaluation and self-evaluation?

Valdas Macionis1.   

Abstract

BACKGROUND: While "diagrammatic" evaluation of finger joint angles using two folded paper strips as goniometric arms has been proposed and could be an alternative to standard goniometry and a means for self-evaluation, the measurement differences and reliability are unknown. QUESTIONS/PURPOSES: This study assessed the standard and diagrammatic finger goniometry performed by an experienced examiner on patients in terms of (1) intragoniometer and intergoniometer (ie, intrarater) differences and reliability; (2) interrater differences and reliability relative to patients' diagrammatic self-evaluation; and (3) the interrater differences related to patient's hand dominance.
METHODS: Sixty-one patients without previous training self-evaluated active extension of all joints of the fifth finger of one hand once using two rectangular strips of paper. A practitioner used a goniometer and a diagram to perform parallel evaluations once in 12 patients and three times in 49 patients. The diagrams were scanned and measured. All evaluations and proportions of differences between the paired measurements of 5° or less were combined for analysis.
RESULTS: Intrarater intraclass correlation coefficients (ICC) based on the second and third practitioner's trials for the proximal interphalangeal joint were greater than 0.99. Reliability was poor when calculations involved the first measurement of the practitioner (ICCs < 0.38). Interrater reliability was poor regardless of the practitioner's trial (ICCs < 0.033). The proportions of the absolute differences of 5° or less between all paired practitioner's measurements were similar. The proportions of the acceptable differences between paired practitioner's and patients' measurements were nonequivalent for the interphalangeal joints. The interrater differences did not depend on patients' handedness.
CONCLUSIONS: In experienced hands both techniques produce clinically comparable reliability, but patients' performance in extempore diagrammatic self-evaluation is inadequate. Further studies are necessary to explore whether appropriate training of patients can improve consistency of diagrammatic self-evaluation.

Entities:  

Mesh:

Year:  2013        PMID: 23292887      PMCID: PMC3706675          DOI: 10.1007/s11999-012-2777-6

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  29 in total

1.  The Littler line method and the area under a Gaussian curve: a new method of assessing digital range of motion.

Authors:  L W Catalano; R H Browne; P R Carter; A C Frobish; M Ezaki; J W Littler
Journal:  J Hand Surg Am       Date:  2001-01       Impact factor: 2.230

2.  Goniometry of the proximal and distal interphalangeal joints, Part II: placement prefereces, interrater reliability, and concurrent validity.

Authors:  G N Groth; K M VanDeven; E C Phillips; R L Ehretsman
Journal:  J Hand Ther       Date:  2001 Jan-Mar       Impact factor: 1.950

3.  A goniometric glove for clinical hand assessment. Construction, calibration and validation.

Authors:  N W Williams; J M Penrose; C M Caddy; E Barnes; D R Hose; P Harley
Journal:  J Hand Surg Br       Date:  2000-04

4.  Measures of reliability in sports medicine and science.

Authors:  W G Hopkins
Journal:  Sports Med       Date:  2000-07       Impact factor: 11.136

5.  Interrater reliability in finger joint goniometer measurement in Dupuytren's disease.

Authors:  Christina Engstrand; Barbro Krevers; Joanna Kvist
Journal:  Am J Occup Ther       Date:  2012 Jan-Feb

6.  Interrater and intrarater reliability of finger goniometric measurements.

Authors:  Erika Lewis; Lynn Fors; William J Tharion
Journal:  Am J Occup Ther       Date:  2010 Jul-Aug

7.  Measurements of wrist and finger postures: a comparison of goniometric and motion capture techniques.

Authors:  James R Cook; Nancy A Baker; Rakie Cham; Erin Hale; Mark S Redfern
Journal:  J Appl Biomech       Date:  2007-02       Impact factor: 1.833

8.  A technique for graphical recording of range of motion using an improvised paper goniometer.

Authors:  Valdas Macionis
Journal:  J Hand Ther       Date:  2011-08-04       Impact factor: 1.950

9.  When to use agreement versus reliability measures.

Authors:  Henrica C W de Vet; Caroline B Terwee; Dirk L Knol; Lex M Bouter
Journal:  J Clin Epidemiol       Date:  2006-08-10       Impact factor: 6.437

10.  Visual and computer software-aided estimates of Dupuytren's contractures: correlation with clinical goniometric measurements.

Authors:  R P Smith; J J Dias; A Ullah; B Bhowal
Journal:  Ann R Coll Surg Engl       Date:  2009-02-13       Impact factor: 1.891