Literature DB >> 20825126

Interrater and intrarater reliability of finger goniometric measurements.

Erika Lewis1, Lynn Fors, William J Tharion.   

Abstract

Intrarater and interrater reliability were determined for middle finger range of motion (ROM) using the Rolyan finger goniometer. Seven raters measured ROM 3 times (trials) on 20 healthy adults. Intraclass reliability analysis and analysis of variance was used to assess the consistency and stability of measures. Level of significance was set at p < or = .05. Significant differences (p < .05) existed between raters for metacarpophalangeal, proximal interphalangeal, and distal interphalangeal active finger ROM measurements and for metacarpophalangeal and proximal interphalangeal passive range of motion. Intrarater reliability ranged from .43 to .99 (single measure intraclass coefficient). Interrater reliability ranged from .24 to .95, with passive measures lower than active measures. These results provide clinicians with evidence for using this specific goniometer and issues associated with various therapists assessing finger ROM.

Mesh:

Year:  2010        PMID: 20825126     DOI: 10.5014/ajot.2010.09028

Source DB:  PubMed          Journal:  Am J Occup Ther        ISSN: 0272-9490


  7 in total

1.  Diamond Stress View Radiograph for Thumb Metacarpophalangeal Hyperextension.

Authors:  Jeffrey A Marchessault; Michael C Knight; Paul A Henkel
Journal:  Hand (N Y)       Date:  2017-12-22

2.  Is diagrammatic goniometry feasible for finger ROM evaluation and self-evaluation?

Authors:  Valdas Macionis
Journal:  Clin Orthop Relat Res       Date:  2013-01-05       Impact factor: 4.176

3.  Minimal detectable difference of the finger and wrist range of motion: comparison of goniometry and 3D motion analysis.

Authors:  Lisa Reissner; Gabriella Fischer; Renate List; William R Taylor; Pietro Giovanoli; Maurizio Calcagni
Journal:  J Orthop Surg Res       Date:  2019-06-10       Impact factor: 2.359

4.  Reliability of the standard goniometry and diagrammatic recording of finger joint angles: a comparative study with healthy subjects and non-professional raters.

Authors:  Valdas Macionis
Journal:  BMC Musculoskelet Disord       Date:  2013-01-09       Impact factor: 2.362

5.  A new method of measuring the thumb pronation and palmar abduction angles during opposition movement using a three-axis gyroscope.

Authors:  Tomoyuki Kuroiwa; Koji Fujita; Akimoto Nimura; Takashi Miyamoto; Toru Sasaki; Atsushi Okawa
Journal:  J Orthop Surg Res       Date:  2018-11-16       Impact factor: 2.359

6.  A Novel Setup and Protocol to Measure the Range of Motion of the Wrist and the Hand.

Authors:  Kostas Nizamis; Noortje H M Rijken; Ana Mendes; Mariska M H P Janssen; Arjen Bergsma; Bart F J M Koopman
Journal:  Sensors (Basel)       Date:  2018-09-25       Impact factor: 3.576

7.  Improving Data Glove Accuracy and Usability Using a Neural Network When Measuring Finger Joint Range of Motion.

Authors:  James Connolly; Joan Condell; Kevin Curran; Philip Gardiner
Journal:  Sensors (Basel)       Date:  2022-03-14       Impact factor: 3.576

  7 in total