Literature DB >> 23292658

Automated T(2) * measurements using supplementary field mapping to assess cardiac iron content.

Brian A Taylor1, Ralf B Loeffler, Ruitian Song, Mary E McCarville, Jane S Hankins, Claudia M Hillenbrand.   

Abstract

PURPOSE: To develop and evaluate an algorithm that automatically identifies high-susceptibility areas and excludes them from T(2) * measurements in the left ventricle (LV) for myocardial iron measurements.
MATERIALS AND METHODS: An autoregressive moving average (ARMA) model was implemented on multigradient echo scans of 24 patients (age range 3-45 years, 10 male/14 female). Voxels with relatively high susceptibility (>3 Hz/mm) were flagged and deselected from the T(2) * calculations for iron quantification. The mean, standard deviation, and coefficient of variation (CoV) of the ARMA-defined region were compared to the CoV of four distinct regions of the LV and the entire LV using a Student's t-test (α = 0.05).
RESULTS: The CoV of T(2) * values obtained by the ARMA method are comparable with that in the interventricular septum (IS), where susceptibility was the lowest (CoV = 0.31). The ARMA method provides a greater area (51.9 ± 13.7% of the LV) to measure T(2) * than that using the IS alone (21.1 ± 3.4%, P < 0.0001). Areas where low susceptibility are measured corroborate with areas reported in previous studies that investigated T(2) * variations throughout the LV.
CONCLUSION: An automated method to measure T(2) * relaxation in the LV with minimal effects from susceptibility has been developed. Variability is reduced while covering more regions for cardiac T2 * calculation.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  T2* mapping; autoregressive moving average (ARMA) modeling; cardiac MR; iron overload; multigradient echo (mGRE); susceptibility

Mesh:

Substances:

Year:  2013        PMID: 23292658      PMCID: PMC3731419          DOI: 10.1002/jmri.23990

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  28 in total

1.  Preferential patterns of myocardial iron overload by multislice multiecho T*2 CMR in thalassemia major patients.

Authors:  Antonella Meloni; Vincenzo Positano; Alessia Pepe; Giuseppe Rossi; MariaChiara Dell'Amico; Cristina Salvatori; Petra Keilberg; Aldo Filosa; Giuseppina Sallustio; Massimo Midiri; Domenico D'Ascola; Maria Filomena Santarelli; Massimo Lombardi
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

2.  Automated detection of left ventricle in 4D MR images: experience from a large study.

Authors:  Xiang Lin; Brett R Cowan; Alistair A Young
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

3.  Autoregressive moving average modeling for spectral parameter estimation from a multigradient echo chemical shift acquisition.

Authors:  Brian A Taylor; Ken-Pin Hwang; John D Hazle; R Jason Stafford
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

Review 4.  Iron overload: consequences, assessment, and monitoring.

Authors:  Ali T Taher; Khaled M Musallam; Adlette Inati
Journal:  Hemoglobin       Date:  2009       Impact factor: 0.849

5.  R2* magnetic resonance imaging of the liver in patients with iron overload.

Authors:  Jane S Hankins; M Beth McCarville; Ralf B Loeffler; Matthew P Smeltzer; Mihaela Onciu; Fredric A Hoffer; Chin-Shang Li; Winfred C Wang; Russell E Ware; Claudia M Hillenbrand
Journal:  Blood       Date:  2009-03-04       Impact factor: 22.113

6.  Absence of cardiac siderosis by MRI T2* despite transfusion burden, hepatic and serum iron overload in Lebanese patients with sickle cell disease.

Authors:  Adlette Inati; Khaled M Musallam; John C Wood; Marwan Sheikh-Taha; Linda Daou; Ali T Taher
Journal:  Eur J Haematol       Date:  2009-09-08       Impact factor: 2.997

7.  Assessment of cardiac iron by MRI susceptometry and R2* in patients with thalassemia.

Authors:  Zhiyue J Wang; Roland Fischer; Zili Chu; Donald H Mahoney; Brigitta U Mueller; Raja Muthupillai; Ellen B James; Rajesh Krishnamurthy; Taylor Chung; Eric Padua; Elliott Vichinsky; Paul Harmatz
Journal:  Magn Reson Imaging       Date:  2010-01-12       Impact factor: 2.546

8.  No evidence for myocardial iron overload and free iron species in multitransfused patients with sickle/beta-thalassaemia.

Authors:  Hussam Ghoti; Orly Goitein; Ariel Koren; Carina Levin; Tamar Kushnir; Eliezer Rachmilewitz; Eli Konen
Journal:  Eur J Haematol       Date:  2009-09-29       Impact factor: 2.997

9.  Susceptibility gradient mapping (SGM): a new postprocessing method for positive contrast generation applied to superparamagnetic iron oxide particle (SPIO)-labeled cells.

Authors:  Hannes Dahnke; Wei Liu; Daniel Herzka; Joseph A Frank; Tobias Schaeffter
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

10.  Cardiac T2* magnetic resonance for prediction of cardiac complications in thalassemia major.

Authors:  P Kirk; M Roughton; J B Porter; J M Walker; M A Tanner; J Patel; D Wu; J Taylor; M A Westwood; L J Anderson; D J Pennell
Journal:  Circulation       Date:  2009-10-02       Impact factor: 29.690

View more
  4 in total

1.  Fast quantitative parameter maps without fitting: Integration yields accurate mono-exponential signal decay rates.

Authors:  Ruitian Song; Ralf B Loeffler; Joseph L Holtrop; M Beth McCarville; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2017-10-30       Impact factor: 4.668

2.  Semi-automated myocardial segmentation of bright blood multi-gradient echo images improves reproducibility of myocardial contours and T2* determination.

Authors:  Pandji Triadyaksa; Niek H J Prakken; Jelle Overbosch; Robin B Peters; J Martijn van Swieten; Matthijs Oudkerk; Paul E Sijens
Journal:  MAGMA       Date:  2016-12-16       Impact factor: 2.310

3.  T2* assessment of the three coronary artery territories of the left ventricular wall by different monoexponential truncation methods.

Authors:  Pandji Triadyaksa; Jelle Overbosch; Matthijs Oudkerk; Paul Eduard Sijens
Journal:  MAGMA       Date:  2022-04-18       Impact factor: 2.533

Review 4.  Cardiac T2 * mapping: Techniques and clinical applications.

Authors:  Pandji Triadyaksa; Matthijs Oudkerk; Paul E Sijens
Journal:  J Magn Reson Imaging       Date:  2019-12-14       Impact factor: 4.813

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.