Literature DB >> 23277714

Role of intervention on laboratory performance: evaluation of quality indicators in a tertiary care hospital.

Rachna Agarwal1, Sujata Chaturvedi, Neelam Chhillar, Renu Goyal, Ishita Pant, Chandra B Tripathi.   

Abstract

Quality in laboratory has huge impact on diagnosis and patient management as 80-90% of all diagnosis is made on the basis of laboratory tests. Monitoring of quality indicators covering the critical areas of pre-analytical, analytical and post-analytical phases like sample misidentification, sample rejection, random and systemic errors, critical value reporting and TATs have a significant impact on performance of laboratory. This study was conducted in diagnostic laboratories receiving approximately 42,562 samples for clinical chemistry, hematology and serology. The list of quality indicators was developed for the steps of total testing process for which errors are frequent and improvements are possible. The trend was observed for all the QI before and after sensitisation of the staff over the period of 12 months. Incomplete test requisition form received in the lab was the most poor quality indicator observed (7.89%), followed by sample rejection rate (4.91%). Most significant improvement was found in pre- and post-analytical phase after sensitisation of staff but did not have much impact on analytical phase. Use of quality indicators to assess and monitor the quality system of the clinical laboratory services is extremely valuable tool in keeping the total testing process under control in a systematic and transparent way.

Entities:  

Keywords:  Analytical phase; Patient safety; Post-analytical phase; Pre-analytical phase; Quality indicator; Total testing process

Year:  2012        PMID: 23277714      PMCID: PMC3286585          DOI: 10.1007/s12291-011-0182-7

Source DB:  PubMed          Journal:  Indian J Clin Biochem        ISSN: 0970-1915


  14 in total

Review 1.  Quality indicators and specifications for the extra-analytical phases in clinical laboratory management.

Authors:  Carmen Ricós; Montserrat García-Victoria; Blanca de la Fuente
Journal:  Clin Chem Lab Med       Date:  2004       Impact factor: 3.694

2.  Governance of preanalytical variability: travelling the right path to the bright side of the moon?

Authors:  Giuseppe Lippi
Journal:  Clin Chim Acta       Date:  2009-03-18       Impact factor: 3.786

3.  Laboratory critical values policies and procedures: a college of American Pathologists Q-Probes Study in 623 institutions.

Authors:  Peter J Howanitz; Steven J Steindel; Nan V Heard
Journal:  Arch Pathol Lab Med       Date:  2002-06       Impact factor: 5.534

4.  Errors in laboratory medicine: practical lessons to improve patient safety.

Authors:  Peter J Howanitz
Journal:  Arch Pathol Lab Med       Date:  2005-10       Impact factor: 5.534

5.  Outpatient phlebotomy success and reasons for specimen rejection.

Authors:  Jane C Dale; David A Novis
Journal:  Arch Pathol Lab Med       Date:  2002-04       Impact factor: 5.534

6.  The IFCC Working Group on laboratory errors and patient safety.

Authors:  Laura Sciacovelli; Mario Plebani
Journal:  Clin Chim Acta       Date:  2009-03-26       Impact factor: 3.786

7.  Survey of critical value reporting and reduction of false-positive critical value results.

Authors:  Anand S Dighe; Jay B Jones; Sue Parham; Kent B Lewandrowski
Journal:  Arch Pathol Lab Med       Date:  2008-10       Impact factor: 5.534

8.  Clinical laboratory specimen rejection--association with the site of patient care and patients' characteristics: findings from a single health care organization.

Authors:  Azadeh Stark; Bruce A Jones; Deborah Chapman; Karen Well; Richard Krajenta; Frederick A Meier; Richard J Zarbo
Journal:  Arch Pathol Lab Med       Date:  2007-04       Impact factor: 5.534

9.  Exploring the iceberg of errors in laboratory medicine.

Authors:  Mario Plebani
Journal:  Clin Chim Acta       Date:  2009-03-18       Impact factor: 3.786

10.  Laboratory safety and the WHO World Alliance for Patient Safety.

Authors:  Layla McCay; Claire Lemer; Albert W Wu
Journal:  Clin Chim Acta       Date:  2009-03-18       Impact factor: 3.786

View more
  8 in total

1.  Diagnostic Laboratories in India: Investigating Quality Characteristics, Productivity and Time of Reporting.

Authors:  Tony C Badrick; Anton Gutscher; Daniel Chin
Journal:  Indian J Clin Biochem       Date:  2017-07-10

2.  Active tracking of rejected dried blood samples in a large program in Nigeria.

Authors:  Auchi Inalegwu; Sunny Phillips; Rawlings Datir; Christopher Chime; Petronilla Ozumba; Samuel Peters; Obinna Ogbanufe; Charles Mensah; Alash'Le Abimiku; Patrick Dakum; Nicaise Ndembi
Journal:  World J Virol       Date:  2016-05-12

3.  Detecting Preanalytical Errors Using Quality Indicators in a Hematology Laboratory.

Authors:  Khalid Alshaghdali; Tessie Y Alcantara; Raja Rezgui; Charlie P Cruz; Munif H Alshammary; Yasser A Almotairi; Jerold C Alcantara
Journal:  Qual Manag Health Care       Date:  2021-09-03       Impact factor: 1.147

4.  Effectiveness of Laboratory Practices to Reducing Patient Misidentification Due to Specimen Labeling Errors at the Time of Specimen Collection in Healthcare Settings: LMBP™ Systematic Review.

Authors:  Paramjit Sandhu; Kakali Bandyopadhyay; Dennis J Ernst; William Hunt; Thomas H Taylor; Rebecca Birch; John Krolak; Sharon Geaghan
Journal:  J Appl Lab Med       Date:  2017-09

5.  Errors in the Total Testing Process in the Clinical Chemistry Laboratory at the University of Gondar Hospital, Northwest Ethiopia.

Authors:  Sintayehu Ambachew; Kasaw Adane; Abebaw Worede; Tadele Melak; Daniel Asmelash; Shewaneh Damtie; Habtamu Wondifraw Baynes; Molla Abebe; Belete Biadgo
Journal:  Ethiop J Health Sci       Date:  2018-03

6.  Common causes of EID sample rejection in Zimbabwe and how to mitigate them.

Authors:  Charles Chiku; Maria Zolfo; Mbazi Senkoro; Mzwandile Mabhala; Hannock Tweya; Patience Musasa; Fungai D Shukusho; Exervia Mazarura; Angela Mushavi; Douglas Mangwanya
Journal:  PLoS One       Date:  2019-08-08       Impact factor: 3.240

7.  Chronometric vs. Structural Hypercoagulability.

Authors:  Carmen Delianu; Mihaela Moscalu; Loredana Liliana Hurjui; Claudia Cristina Tărniceriu; Oana-Viola Bădulescu; Ludmila Lozneanu; Ion Hurjui; Ancuta Goriuc; Zinovia Surlari; Liliana Foia
Journal:  Medicina (Kaunas)       Date:  2020-12-28       Impact factor: 2.430

8.  Applicability of commercial clinical chemistry test kits for horse serum.

Authors:  Yoseph Cherinet Megerssa; Fikru Regassa Gari; Fanos Tadesse Woldemariyam
Journal:  BMC Res Notes       Date:  2021-01-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.