Literature DB >> 23269745

Finite-element-based matching of pre- and intraoperative data for image-guided endovascular aneurysm repair.

Aurélien Duménil1, Adrien Kaladji, Miguel Castro, Simon Esneault, Antoine Lucas, Michel Rochette, Cemil Göksu, Pascal Haigron.   

Abstract

Endovascular repair of abdominal aortic aneurysms is a well-established technique throughout the medical and surgical communities. Although increasingly indicated, this technique does have some limitations. Because intervention is commonly performed under fluoroscopic control, 2-D visualization of the aneurysm requires the injection of a contrast agent. The projective nature of this imaging modality inevitably leads to topographic errors, and does not give information on arterial wall quality at the time of deployment. A specially adapted intraoperative navigation interface could increase deployment accuracy and reveal such information, which preoperative 3-D imaging might otherwise provide. One difficulty is the precise matching of preoperative data (images and models) and intraoperative observations affected by anatomical deformations due to tool-tissue interactions. Our proposed solution involves a finite-element-based preoperative simulation of tool-tissue interactions, its adaptive tuning regarding patient specific data, and the matching with intraoperative data. The biomechanical model was first tuned on a group of ten patients and assessed on a second group of eight patients.

Entities:  

Mesh:

Year:  2012        PMID: 23269745      PMCID: PMC3998907          DOI: 10.1109/TBME.2012.2235440

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  24 in total

1.  Validation of a two- to three-dimensional registration algorithm for aligning preoperative CT images and intraoperative fluoroscopy images.

Authors:  G P Penney; P G Batchelor; D L Hill; D J Hawkes; J Weese
Journal:  Med Phys       Date:  2001-06       Impact factor: 4.071

2.  Wall stress studies of abdominal aortic aneurysm in a clinical model.

Authors:  M J Thubrikar; J al-Soudi; F Robicsek
Journal:  Ann Vasc Surg       Date:  2001-05       Impact factor: 1.466

Review 3.  Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair.

Authors:  Elliot L Chaikof; Mark F Fillinger; Jon S Matsumura; Robert B Rutherford; Geoffrey H White; Jan D Blankensteijn; Victor M Bernhard; Peter L Harris; K Craig Kent; James May; Frank J Veith; Christopher K Zarins
Journal:  J Vasc Surg       Date:  2002-05       Impact factor: 4.268

4.  Regional distribution of wall thickness and failure properties of human abdominal aortic aneurysm.

Authors:  Madhavan L Raghavan; Jarin Kratzberg; Erasmo Magalhães Castro de Tolosa; Mauro M Hanaoka; Patricia Walker; Erasmo Simão da Silva
Journal:  J Biomech       Date:  2005-12-09       Impact factor: 2.712

5.  Effects of wall calcifications in patient-specific wall stress analyses of abdominal aortic aneurysms.

Authors:  Lambert Speelman; Ajay Bohra; E Marielle H Bosboom; Geert Willem H Schurink; Frans N van de Vosse; Michel S Makaorun; David A Vorp
Journal:  J Biomech Eng       Date:  2007-02       Impact factor: 2.097

6.  Assessment of image intensifier and distortion for DSA localization studies.

Authors:  E Coste; D Gibon; J Rousseau
Journal:  Br J Radiol       Date:  1997-01       Impact factor: 3.039

7.  Blood flow and structure interactions in a stented abdominal aortic aneurysm model.

Authors:  Zhonghua Li; Clement Kleinstreuer
Journal:  Med Eng Phys       Date:  2005-06       Impact factor: 2.242

8.  Wall stress distribution on three-dimensionally reconstructed models of human abdominal aortic aneurysm.

Authors:  M L Raghavan; D A Vorp; M P Federle; M S Makaroun; M W Webster
Journal:  J Vasc Surg       Date:  2000-04       Impact factor: 4.268

9.  Virtual evaluation of stent graft deployment: a validated modeling and simulation study.

Authors:  S De Bock; F Iannaccone; G De Santis; M De Beule; D Van Loo; D Devos; F Vermassen; P Segers; B Verhegghe
Journal:  J Mech Behav Biomed Mater       Date:  2012-05-12

10.  Static circumferential tangential modulus of human atherosclerotic tissue.

Authors:  H M Loree; A J Grodzinsky; S Y Park; L J Gibson; R T Lee
Journal:  J Biomech       Date:  1994-02       Impact factor: 2.712

View more
  2 in total

1.  A versatile intensity-based 3D/2D rigid registration compatible with mobile C-arm for endovascular treatment of abdominal aortic aneurysm.

Authors:  A Duménil; A Kaladji; M Castro; C Göksu; A Lucas; P Haigron
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-26       Impact factor: 2.924

2.  Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study.

Authors:  M M Sieren; C Schareck; M Kaschwich; M Horn; F Matysiak; E Stahlberg; F Wegner; T H Oechtering; J Barkhausen; J Goltz
Journal:  CVIR Endovasc       Date:  2021-06-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.