Literature DB >> 11439472

Validation of a two- to three-dimensional registration algorithm for aligning preoperative CT images and intraoperative fluoroscopy images.

G P Penney1, P G Batchelor, D L Hill, D J Hawkes, J Weese.   

Abstract

We present a validation of an intensity based two- to three-dimensional image registration algorithm. The algorithm can register a CT volume to a single-plane fluoroscopy image. Four routinely acquired clinical data sets from patients who underwent endovascular treatment for an abdominal aortic aneurysm were used. Each data set was comprised of two intraoperative fluoroscopy images and a preoperative CT image. Regions of interest (ROI) were drawn around each vertebra in the CT and fluoroscopy images. Each CT image ROI was individually registered to the corresponding ROI in the fluoroscopy images. A cross validation approach was used to obtain a measure of registration consistency. Spinal movement between the preoperative and intraoperative scene was accounted for by using two fluoroscopy images. The consistency and robustness of the algorithm when using two similarity measures, pattern intensity and gradient difference, was investigated. Both similarity measures produced similar results. The consistency values were rotational errors below 0.74 degree and in-plane translational errors below 0.90 mm. These errors approximately relate to a two-dimensional projection error of 1.3 mm. The failure rate was less than 8.3% for three of the four data sets. However, for one of the data sets a much larger failure rate (28.5%) occurred.

Entities:  

Mesh:

Year:  2001        PMID: 11439472     DOI: 10.1118/1.1373400

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Automated 2D-3D registration of a radiograph and a cone beam CT using line-segment enhancement.

Authors:  Reshma Munbodh; David A Jaffray; Douglas J Moseley; Zhe Chen; Jonathan P S Knisely; Pascal Cathier; James S Duncan
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  Automatic registration of CT volumes and dual-energy digital radiography for detection of cardiac and lung diseases.

Authors:  Baowei Fei; Xiang Chen; Hesheng Wang; John M Sabol; Elena DuPont; Robert C Gilkeson
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

3.  Automatic 3D-to-2D registration for CT and dual-energy digital radiography for calcification detection.

Authors:  Xiang Chen; Robert C Gilkeson; Baowei Fei
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

4.  Automated 2D-3D registration of portal images and CT data using line-segment enhancement.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

5.  Vesselness-based 2D-3D registration of the coronary arteries.

Authors:  Daniel Ruijters; Bart M ter Haar Romeny; Paul Suetens
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-05-07       Impact factor: 2.924

6.  A comparative analysis of intensity-based 2D-3D registration for intraoperative use in pedicle screw insertion surgeries.

Authors:  Hooman Esfandiari; Carolyn Anglin; Pierre Guy; John Street; Simon Weidert; Antony J Hodgson
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-10       Impact factor: 2.924

7.  Validation for 2D/3D registration. II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set.

Authors:  Christelle Gendrin; Primoz Markelj; Supriyanto Ardjo Pawiro; Jakob Spoerk; Christoph Bloch; Christoph Weber; Michael Figl; Helmar Bergmann; Wolfgang Birkfellner; Bostjan Likar; Franjo Pernus
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

8.  Method comparison of automated matching software-assisted cone-beam CT and stereoscopic kilovoltage x-ray positional verification image-guided radiation therapy for head and neck cancer: a prospective analysis.

Authors:  Clifton D Fuller; Todd J Scarbrough; Jan-Jakob Sonke; Coen R N Rasch; Mehee Choi; Joe Y Ting; Samuel J Wang; Niko Papanikolaou; David I Rosenthal
Journal:  Phys Med Biol       Date:  2009-11-24       Impact factor: 3.609

Review 9.  Cardiac image integration implications for atrial fibrillation ablation.

Authors:  Jasbir Sra
Journal:  J Interv Card Electrophysiol       Date:  2008-03-25       Impact factor: 1.900

10.  Finite-element-based matching of pre- and intraoperative data for image-guided endovascular aneurysm repair.

Authors:  Aurélien Duménil; Adrien Kaladji; Miguel Castro; Simon Esneault; Antoine Lucas; Michel Rochette; Cemil Göksu; Pascal Haigron
Journal:  IEEE Trans Biomed Eng       Date:  2012-12-20       Impact factor: 4.538