Literature DB >> 2324820

Left ventricular volume calculation using a count-based ratio method applied to multigated radionuclide angiography.

T Massardo1, R A Gal, R P Grenier, D H Schmidt, S C Port.   

Abstract

The purpose of this study was to investigate the accuracy of a new count-proportional method for the measurement of left ventricular volume when applied to gated equilibrium blood-pool imaging. An equation is developed that relates total chamber volume, Vt, to the area of a pixel (M) and the ratio (R) of total counts within the chamber to the counts within the hottest pixel in the chamber such that Vt = 1.38 M3R3/2. The value of M is a constant for the particular scintillation camera-collimator system and R is obtained from observed count rates. All calculated volumes were compared to volumes measured using biplane contrast ventriculography. In 25 patients, the method for ventricular volumes gave an r of 0.95 and an s.e.e. of 23 ml [Volume (nuclear) = 0.94 Volume (cath) + 1.3]. Endsystolic volume was best calculated from end-diastolic volume and ejection fraction. Manual regions of interest were more accurate than automated regions of interest. This method appears to be as accurate as more complex approaches and has the advantage of not requiring attenuation correction or blood sampling.

Entities:  

Mesh:

Year:  1990        PMID: 2324820

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  18 in total

1.  Reduced septal glucose metabolism predicts response to cardiac resynchronization therapy.

Authors:  David Birnie; Rob A de Kemp; Anthony S Tang; Terence D Ruddy; Michael H Gollob; Ann Guo; Kathryn Williams; Kerry Thomson; Jean N DaSilva; Rob S Beanlands
Journal:  J Nucl Cardiol       Date:  2011-12-10       Impact factor: 5.952

Review 2.  Measurement of ventricular function with scintigraphic techniques: part I-imaging hardware, radiopharmaceuticals, and first-pass radionuclide angiography.

Authors:  Kim A Williams
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

3.  Improved assessment of left ventricular volumes and ejection fraction by contrast enhanced harmonic color Doppler echocardiography.

Authors:  Gian Paolo Bezante; Gian Marco Rosa; Riccardo Bruni; Xucai Chen; Giuseppe Villa; Alice Scopinaro; Manrico Balbi; Antonio Barsotti; Karl Q Schwarz
Journal:  Int J Cardiovasc Imaging       Date:  2005-12       Impact factor: 2.357

4.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

5.  Equilibrium radionuclide angiocardiography.

Authors:  James R Corbett; Olakunle O Akinboboye; Stephen L Bacharach; Jeffrey S Borer; Elias H Botvinick; E Gordon DePuey; Edward P Ficaro; Christopher L Hansen; Milena J Henzlova; Serge Van Kriekinge
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

6.  EANM/ESC guidelines for radionuclide imaging of cardiac function.

Authors:  B Hesse; T B Lindhardt; W Acampa; C Anagnostopoulos; J Ballinger; J J Bax; L Edenbrandt; A Flotats; G Germano; T Gmeiner Stopar; P Franken; A Kelion; A Kjaer; D Le Guludec; M Ljungberg; A F Maenhout; C Marcassa; J Marving; F McKiddie; W M Schaefer; L Stegger; R Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-04       Impact factor: 9.236

7.  Optimization and validation of radionuclide angiography phase analysis parameters for quantification of mechanical dyssynchrony.

Authors:  Richard Wassenaar; David O'Connor; Barbora Dej; Terrence David Ruddy; David Birnie
Journal:  J Nucl Cardiol       Date:  2009-07-22       Impact factor: 5.952

8.  SPECT gated blood pool phase analysis of lateral wall motion for prediction of CRT response.

Authors:  Michel Lalonde; David Birnie; Terrence D Ruddy; Robert A deKemp; Rob S B Beanlands; Richard Wassenaar; R Glenn Wells
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-09       Impact factor: 2.357

9.  Comparison of interstudy reproducibility of equilibrium electrocardiography-gated SPECT radionuclide angiography versus planar radionuclide angiography for the quantification of global left ventricular function.

Authors:  Doumit Daou; Carlos Coaguila; Abdel Benada
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

10.  Repeatability of automatic left ventricular cavity volume measurements from myocardial perfusion SPECT.

Authors:  G Germano; P B Kavanagh; J T Kavanagh; S H Wishner; D S Berman; G J Kavanagh
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

View more