Literature DB >> 23245827

Non-rigid image registration based strain estimator for intravascular ultrasound elastography.

Michael S Richards1, Marvin M Doyley.   

Abstract

Intravascular ultrasound elastography (IVUSe) could improve the diagnosis of cardiovascular disease by revealing vulnerable plaques through their mechanical tissue properties. To improve the performance of IVUSe, we developed and implemented a non-rigid image-registration method to visualize the radial and circumferential component of strain within vascular tissues. We evaluated the algorithm's performance with four initialization schemes using simulated and experimentally acquired ultrasound images. Applying the registration method to radio-frequency (RF) echo frames improved the accuracy of displacements compared to when B-mode images were employed. However, strain elastograms measured from RF echo frames produce erroneous results when both the zero-initialization method and the mesh-refinement scheme were employed. For most strain levels, the cross-correlation-initialization method produced the best performance. The simulation study predicted that elastograms obtained from vessels with average strains in the range of 3%-5% should have high elastographic signal-to-noise ratio (SNRe)-on the order of 4.5 and 7.5 for the radial and circumferential components of strain, respectively. The preliminary in vivo validation study (phantom and an atherosclerotic rabbit) demonstrated that the non-rigid registration method could produce useful radial and circumferential strain elastograms under realistic physiologic conditions. The results of this investigation were sufficiently encouraging to warrant a more comprehensive in vivo validation. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2012        PMID: 23245827      PMCID: PMC3653308          DOI: 10.1016/j.ultrasmedbio.2012.09.023

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  41 in total

Review 1.  Elastography: ultrasonic estimation and imaging of the elastic properties of tissues.

Authors:  J Ophir; S K Alam; B Garra; F Kallel; E Konofagou; T Krouskop; T Varghese
Journal:  Proc Inst Mech Eng H       Date:  1999       Impact factor: 1.617

2.  Strain imaging and elasticity reconstruction of arteries based on intravascular ultrasound video images.

Authors:  M Wan; Y Li; J Li; Y Cui; X Zhou
Journal:  IEEE Trans Biomed Eng       Date:  2001-01       Impact factor: 4.538

3.  Feature-adaptive motion tracking of ultrasound image sequences using a deformable mesh.

Authors:  F Yeung; S F Levinson; D Fu; K J Parker
Journal:  IEEE Trans Med Imaging       Date:  1998-12       Impact factor: 10.048

4.  A theoretical framework for performance characterization of elastography: the strain filter.

Authors:  T Varghese; J Ophir
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1997       Impact factor: 2.725

5.  Estimation of the transverse strain tensor in the arterial wall using IVUS image registration.

Authors:  Yun Liang; Hui Zhu; Morton H Friedman
Journal:  Ultrasound Med Biol       Date:  2008-07-14       Impact factor: 2.998

6.  Performance evaluation of different implementations of the Lagrangian speckle model estimator for non-invasive vascular ultrasound elastography.

Authors:  Elizabeth Mercure; Guy Cloutier; Cédric Schmitt; Roch L Maurice
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

7.  A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues.

Authors:  E Konofagou; J Ophir
Journal:  Ultrasound Med Biol       Date:  1998-10       Impact factor: 2.998

8.  Ultrasonic measurement of differential displacement and strain in a vascular model.

Authors:  L K Ryan; F S Foster
Journal:  Ultrason Imaging       Date:  1997-01       Impact factor: 1.578

9.  Deviations from Rayleigh statistics in ultrasonic speckle.

Authors:  T A Tuthill; R H Sperry; K J Parker
Journal:  Ultrason Imaging       Date:  1988-04       Impact factor: 1.578

10.  In vitro analysis of coronary atheromatous lesions by intravascular ultrasound; reproducibility and histological correlation of lesion morphology.

Authors:  N D Palmer; D Northridge; A Lessells; W N McDicken; K A Fox
Journal:  Eur Heart J       Date:  1999-12       Impact factor: 29.983

View more
  10 in total

1.  Visualizing the stress distribution within vascular tissues using intravascular ultrasound elastography: a preliminary investigation.

Authors:  Michael S Richards; Renato Perucchio; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2015-03-31       Impact factor: 2.998

2.  Contrast-Enhanced Quantitative Intravascular Elastography: The Impact of Microvasculature on Model-Based Elastography.

Authors:  Steven Huntzicker; Himanshu Shekhar; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2016-02-26       Impact factor: 2.998

3.  Spatial distribution of airway wall displacements during breathing and bronchoconstriction measured by ultrasound elastography using finite element image registration.

Authors:  Brian C Harvey; Kenneth R Lutchen; Paul E Barbone
Journal:  Ultrasonics       Date:  2016-11-29       Impact factor: 2.890

4.  Detecting Regional Stiffness Changes in Aortic Aneurysmal Geometries Using Pressure-Normalized Strain.

Authors:  Doran S Mix; Ling Yang; Camille C Johnson; Nathan Couper; Ben Zarras; Isaac Arabadjis; Lauren E Trakimas; Michael C Stoner; Steven W Day; Michael S Richards
Journal:  Ultrasound Med Biol       Date:  2017-07-17       Impact factor: 2.998

5.  Approaches to accommodate noisy data in the direct solution of inverse problems in incompressible plane-strain elasticity.

Authors:  U Albocher; P E Barbone; M S Richards; A A Oberai; I Harari
Journal:  Inverse Probl Sci Eng       Date:  2014       Impact factor: 1.950

6.  Impingement in Insertional Achilles Tendinopathy Occurs Across a Larger Range of Ankle Angles and Is Associated With Increased Tendon Thickness.

Authors:  Anthony N Aggouras; Ruth L Chimenti; A Samuel Flemister; John Ketz; Laura C Slane; Mark R Buckley; Michael S Richards
Journal:  Foot Ankle Int       Date:  2022-01-27       Impact factor: 3.569

7.  Segmental Analysis of Cardiac Short-Axis Views Using Lagrangian Radial and Circumferential Strain.

Authors:  Chi Ma; Xiao Wang; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2015-11-16       Impact factor: 1.578

8.  Ultrasound strain mapping of Achilles tendon compressive strain patterns during dorsiflexion.

Authors:  Ruth L Chimenti; A Samuel Flemister; John Ketz; Mary Bucklin; Mark R Buckley; Michael S Richards
Journal:  J Biomech       Date:  2015-11-30       Impact factor: 2.712

9.  Model-based vascular elastography improves the detection of flow-induced carotid artery remodeling in mice.

Authors:  Vyacheslav A Korshunov; Hexuan Wang; Rifat Ahmed; Deanne M Mickelsen; Qian Zhou; Chen Yan; Marvin M Doyley
Journal:  Sci Rep       Date:  2017-09-21       Impact factor: 4.379

10.  Ultrasound 2D strain measurement for arm lymphedema using deformable registration: A feasibility study.

Authors:  Xiaofeng Yang; Mylin Torres; Stephanie Kirkpatrick; Walter J Curran; Tian Liu
Journal:  PLoS One       Date:  2017-08-30       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.