Literature DB >> 18244114

A theoretical framework for performance characterization of elastography: the strain filter.

T Varghese1, J Ophir.   

Abstract

This paper presents a theoretical framework for performance characterization in strain estimation, which includes the effect of signal decorrelation, quantization errors due to the finite temporal sampling rate, and electronic noise. An upper bound on the performance of the strain estimator in elastography is obtained from a strain filter constructed using these limits. The strain filter is a term used to describe the nonlinear filtering process in the strain domain (due to the ultrasound system and signal processing parameters) that allows the elastographic depiction of a limited range of strains from the compressed tissue. The strain filter predicts the elastogram quality by specifying the elastographic signal-to-noise ratio (SNR(e)), sensitivity, and the strain dynamic range at a given resolution. The dynamic range is limited by decorrelation errors for large tissue strain values, and electronic noise for low strain values. Tradeoffs between different techniques used to enhance elastogram image quality may also be analyzed using the strain filter.

Year:  1997        PMID: 18244114     DOI: 10.1109/58.585212

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  67 in total

1.  Ultrasonic tracking of shear waves using a particle filter.

Authors:  Atul N Ingle; Chi Ma; Tomy Varghese
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

2.  Visualizing the stress distribution within vascular tissues using intravascular ultrasound elastography: a preliminary investigation.

Authors:  Michael S Richards; Renato Perucchio; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2015-03-31       Impact factor: 2.998

3.  Improvements in elastographic contrast-to-noise ratio using spatial-angular compounding.

Authors:  Udomchai Techavipoo; Tomy Varghese
Journal:  Ultrasound Med Biol       Date:  2005-04       Impact factor: 2.998

4.  Spatial angular compounding for elastography without the incompressibility assumption.

Authors:  Min Rao; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2005-10       Impact factor: 1.578

5.  Spatial-angular compounding for elastography using beam steering on linear array transducers.

Authors:  Min Rao; Quan Chen; Hairong Shi; Tomy Varghese
Journal:  Med Phys       Date:  2006-03       Impact factor: 4.071

6.  A novel performance descriptor for ultrasonic strain imaging: a preliminary study.

Authors:  Jingfeng Jiang; Timothy J Hall; Amy M Sommer
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

7.  Optimization of Transmit Parameters in Cardiac Strain Imaging With Full and Partial Aperture Coherent Compounding.

Authors:  Vincent Sayseng; Julien Grondin; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-05       Impact factor: 2.725

8.  Comparison of cardiac displacement and strain imaging using ultrasound radiofrequency and envelope signals.

Authors:  Chi Ma; Tomy Varghese
Journal:  Ultrasonics       Date:  2012-11-29       Impact factor: 2.890

9.  An approach to unbiased subsample interpolation for motion tracking.

Authors:  Matthew M McCormick; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

10.  Variance and covariance of accumulated displacement estimates.

Authors:  Matthew Bayer; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.