Risk factors for ceramic liner fracture after total hip arthroplasty.

Francesco Traina1, Marcello De Fine, Barbara Bordini, Aldo Toni.   

Abstract

The aim of this study was to detect risk factors for ceramic liner fractures. 26 cementless ceramic on ceramic (COC) total hip arthroplasties (THA) revised because of ceramic liner fracture in 24 patients were compared with 49 well-functioning COC THA performed in 49 patients. Demographic parameters, type of ceramic of the liner, size and neck length of the femoral head, cup abduction angle, cup anteversion, femoral off-set, height of the centre of rotation and the incidence of noisy hips during follow-up examination were compared. A greater number of cups placed outside the optimal range of cup anteversion was found in the fracture group (p = 0.03). An audible noise was detected in 21 cases (80.7%) in the fracture group and in 3 cases (6.1%) in the non-fracture group (p = 0.001). A cup anteversion angle out of the optimal range of 15˚+/-10˚ was found to be a risk factor for ceramic liner fracture and the presence of a noisy hip frequently anticipated the failure. In our opinion neck-to-cup impingement with head subluxation and edge loading on the liner rim could have an important role in the onset of noise and subsequent liner failure, and cup malposition contributes to this mechanism of failure.

Entities:  

Mesh:

Year:  2012        PMID: 23233184     DOI: 10.5301/HIP.2012.10339

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  16 in total

1.  Comparative effectiveness of ceramic-on-ceramic implants in stemmed hip replacement: a multinational study of six national and regional registries.

Authors:  Art Sedrakyan; Stephen Graves; Barbara Bordini; Miquel Pons; Leif Havelin; Susan Mehle; Elizabeth Paxton; Thomas Barber; Guy Cafri
Journal:  J Bone Joint Surg Am       Date:  2014-12-17       Impact factor: 5.284

2.  Catastrophic ceramic liner failure-The subtle signs of a non-engaged ceramic liner.

Authors:  Andrew Walls; Adam Tucker; David S Warnock; David Beverland
Journal:  J Orthop       Date:  2018-02-20

3.  Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  George K Karidakis; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

Review 4.  Safe clinical use of carbon nanotubes as innovative biomaterials.

Authors:  Naoto Saito; Hisao Haniu; Yuki Usui; Kaoru Aoki; Kazuo Hara; Seiji Takanashi; Masayuki Shimizu; Nobuyo Narita; Masanori Okamoto; Shinsuke Kobayashi; Hiroki Nomura; Hiroyuki Kato; Naoyuki Nishimura; Seiichi Taruta; Morinobu Endo
Journal:  Chem Rev       Date:  2014-04-10       Impact factor: 60.622

Review 5.  Evolution of total hip arthroplasty in patients younger than 30 years of age: A systematic review and meta-analysis.

Authors:  Andrew Konopitski; Chielozor Okafor; Brendan Smith; Keith Baldwin; Neil P Sheth
Journal:  Arch Orthop Trauma Surg       Date:  2022-02-07       Impact factor: 3.067

6.  Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?

Authors:  Henri Migaud; Sophie Putman; Grégory Kern; Ronald Isida; Julien Girard; Nassima Ramdane; Christian P Delaunay; Moussa Hamadouche
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

Review 7.  Review on squeaking hips.

Authors:  Yadin David Levy; Selin Munir; Shane Donohoo; William Lindsay Walter
Journal:  World J Orthop       Date:  2015-11-18

8.  Midterm analysis of the seleXys cup with ceramic inlay.

Authors:  Tamas Halasi; David Kieser; Christopher M A Frampton; Gary J Hooper
Journal:  Arthroplast Today       Date:  2016-11-09

9.  Total hip arthroplasty: Survival and modes of failure.

Authors:  Theofilos Karachalios; George Komnos; Antonios Koutalos
Journal:  EFORT Open Rev       Date:  2018-05-21

Review 10.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

View more