Literature DB >> 29881154

Catastrophic ceramic liner failure-The subtle signs of a non-engaged ceramic liner.

Andrew Walls1, Adam Tucker1, David S Warnock1, David Beverland1.   

Abstract

Ceramic earrings have an established and successful history in total hip replacement. Occasionally, these articulations have problems, which include squeaking and implant fracture.

Entities:  

Year:  2018        PMID: 29881154      PMCID: PMC5990118          DOI: 10.1016/j.jor.2018.02.004

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  9 in total

Review 1.  Ceramic-on-ceramic bearings in hip arthroplasty: state of the art and the future.

Authors:  J R T Jeffers; W L Walter
Journal:  J Bone Joint Surg Br       Date:  2012-06

2.  Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience.

Authors:  Aldo Toni; Francesco Traina; Susanna Stea; Alessandra Sudanese; Manuela Visentin; Barbara Bordini; Stefano Squarzoni
Journal:  J Bone Joint Surg Am       Date:  2006-12       Impact factor: 5.284

3.  Ceramics in total hip arthroplasty: a bearing solution?

Authors:  J A Skinner; F S Haddad
Journal:  Bone Joint J       Date:  2017-08       Impact factor: 5.082

4.  Ceramic bearings for total hip arthroplasty have high survivorship at 10 years.

Authors:  James A D'Antonio; William N Capello; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

5.  Risk factors for ceramic liner fracture after total hip arthroplasty.

Authors:  Francesco Traina; Marcello De Fine; Barbara Bordini; Aldo Toni
Journal:  Hip Int       Date:  2012 Nov-Dec       Impact factor: 2.135

6.  Ceramic liner fracture and impingement in total hip arthroplasty.

Authors:  Amy Steinhoff; Victor Hakim; Richard H Walker; Clifford W Colwell; Steven N Copp
Journal:  HSS J       Date:  2014-10-21

7.  Do obesity and/or stripe wear increase ceramic liner fracture risk? An XFEM analysis.

Authors:  Jacob M Elkins; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

8.  Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner.

Authors:  M G Zywiel; J-M Brandt; C B Overgaard; A C Cheung; T R Turgeon; K A Syed
Journal:  Bone Joint J       Date:  2013-01       Impact factor: 5.082

9.  Ceramic-on-ceramic bearing fractures in total hip arthroplasty: an analysis of data from the National Joint Registry.

Authors:  D P Howard; P D H Wall; M A Fernandez; H Parsons; P W Howard
Journal:  Bone Joint J       Date:  2017-08       Impact factor: 5.082

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.