Literature DB >> 23219929

Rapid and sensitive detection of shrimp yellow head virus by loop-mediated isothermal amplification combined with a lateral flow dipstick.

Sasiwarat Khunthong1, Wansadaj Jaroenram, Narong Arunrut, Rungkarn Suebsing, Idsada Mungsantisuk, Wansika Kiatpathomchai.   

Abstract

Yellow head virus (YHV) is a highly virulent pathogen that has caused severe mortality in cultivated shrimp (Penaeus monodon and Penaeus vannamei) in Thailand. There are several technologies that are applied to detect YHV for further control of the disease. RT-PCR is currently widely used in the laboratory, but it has some disadvantages related to cost, time-consuming and complexity. An alternative assay combines RT with loop-mediated isothermal amplification (LAMP) that not only provides high specificity, sensitivity and rapidity, but is also cheaper and more suitable for field applications in shrimp aquaculture than the RT-PCR. RT-LAMP is performed under isothermal conditions with a set of four to six primers designed to recognize six to eight distinct target sequences, and it has been combined with a chromatographic lateral-flow dipstick (LFD) to detect LAMP amplified product, which avoids the use of gel electrophoresis. In this study, RT-LAMP for the detection of YHV was developed by isothermal amplification at 65 °C for 45 min, followed by hybridization with an FITC-labeled DNA probe for 5 min and detected by LFD within 5 min (time required approximately 55 min, excluding RNA extraction and preparation time). The detection limit of RT-LAMP-LFD was 0.1 pg RNA extracted from shrimp infected with YHV equivalent to the nested RT-PCR, and no cross reaction was observed with other common shrimp viral pathogens. The LAMP method described in this study showed a rapid, high sensitivity and specificity and it is recommended as user-friendly for diagnosis of YHV in the field.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23219929     DOI: 10.1016/j.jviromet.2012.11.041

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  9 in total

Review 1.  New nucleic acid testing devices to diagnose infectious diseases in resource-limited settings.

Authors:  P Maffert; S Reverchon; W Nasser; C Rozand; H Abaibou
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-06-01       Impact factor: 3.267

2.  Coupling Sensitive Nucleic Acid Amplification with Commercial Pregnancy Test Strips.

Authors:  Yan Du; Arti Pothukuchy; Jimmy D Gollihar; Armin Nourani; Bingling Li; Andrew D Ellington
Journal:  Angew Chem Int Ed Engl       Date:  2016-12-19       Impact factor: 15.336

3.  Application of loop-mediated isothermal amplification combined with lateral flow dipstick to rapid and sensitive detection of Alexandrium catenella.

Authors:  Liang Wang; Guofu Chen; Chunyun Zhang; Yuanyuan Wang; Rui Sun
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-11       Impact factor: 4.223

Review 4.  Viral Shrimp Diseases Listed by the OIE: A Review.

Authors:  Dain Lee; Young-Bin Yu; Jae-Ho Choi; A-Hyun Jo; Su-Min Hong; Ju-Chan Kang; Jun-Hwan Kim
Journal:  Viruses       Date:  2022-03-12       Impact factor: 5.048

5.  Demonstration of a very inexpensive, turbidimetric, real-time, RT-LAMP detection platform using shrimp Laem-Singh virus (LSNV) as a model.

Authors:  Narong Arunrut; Rungkarn Suebsing; Boonsirm Withyachumnarnkul; Wansika Kiatpathomchai
Journal:  PLoS One       Date:  2014-09-25       Impact factor: 3.240

Review 6.  Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organisms.

Authors:  Y-P Wong; S Othman; Y-L Lau; S Radu; H-Y Chee
Journal:  J Appl Microbiol       Date:  2018-02-12       Impact factor: 3.772

7.  Establishment and application of cross-priming isothermal amplification coupled with lateral flow dipstick (CPA-LFD) for rapid and specific detection of red-spotted grouper nervous necrosis virus.

Authors:  Zi Dan Su; Cheng Yin Shi; Jie Huang; Gui Ming Shen; Jin Li; Sheng Qiang Wang; Chao Fan
Journal:  Virol J       Date:  2015-09-26       Impact factor: 4.099

8.  Rapid and sensitive detection of Candidatus Liberibacter asiaticus by loop mediated isothermal amplification combined with a lateral flow dipstick.

Authors:  Luciano A Rigano; Florencia Malamud; Ingrid G Orce; Maria P Filippone; Maria R Marano; Alexandre Morais do Amaral; Atilio P Castagnaro; Adrian A Vojnov
Journal:  BMC Microbiol       Date:  2014-04-06       Impact factor: 3.605

9.  Loop-mediated isothermal amplification-lateral-flow dipstick (LAMP-LFD) to detect Mycoplasma ovipneumoniae.

Authors:  Jie Zhang; Junjun Cao; Mingsong Zhu; Mingguo Xu; Feng Shi
Journal:  World J Microbiol Biotechnol       Date:  2019-01-30       Impact factor: 3.312

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.