Literature DB >> 23218558

Radiographic outcomes of volar locked plating for distal radius fractures.

Megan E Mignemi1, Ian R Byram, Carmen C Wolfe, Kang-Hsien Fan, Elizabeth A Koehler, John J Block, Martin I Jordanov, Jeffry T Watson, Douglas R Weikert, Donald H Lee.   

Abstract

PURPOSE: To assess the ability of volar locked plating to achieve and maintain normal radiographic parameters for articular stepoff, volar tilt, radial inclination, ulnar variance, and radial height in distal radius fractures.
METHODS: We performed a retrospective review of 185 distal radius fractures that underwent volar locked plating with a single plate design over a 5-year period. We reviewed radiographs and recorded measurements for volar tilt, radial inclination, ulnar variance, radial height, and articular stepoff. We used logistic regression to determine the association between return to radiographic standard norms and fracture type.
RESULTS: At the first and final postoperative follow-up visits, we observed articular congruence less than 2 mm in 92% of fractures at both times. Normal volar tilt (11°) was restored in 46% at the first follow-up and 48% at the final one. Radial inclination (22°) was achieved in 44% at the first follow-up and 43% at the final one, and ulnar variance (01 ± 2 mm) was achieved in 53% at the first follow-up and 53% at the final one. In addition, radial height (14 ± 1mm) was restored in 14% at the first follow-up and 12% at the final one. More complex, intra-articular fractures (AO class B and C and Frykman types 3, 4, 7, and 8) were less likely to be restored to normal radiographic parameters. However, because of the small sample size for some fracture types, it was difficult to discover significant associations between fracture type and radiographic outcome.
CONCLUSIONS: Volar locked plating for distal radius fractures achieved articular stepoff less than 2 mm in most fractures but only restored and maintained normal radiographic measurements for volar tilt, radial inclination, and ulnar variance in 50% of fractures. The ability of volar locked plating to restore and maintain ulnar variance and volar tilt decreased with more complex intra-articular fracture types. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23218558      PMCID: PMC3581353          DOI: 10.1016/j.jhsa.2012.10.007

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  42 in total

Review 1.  Radiographic evaluation of the wrist: what does the hand surgeon want to know?

Authors:  F A Mann; A J Wilson; L A Gilula
Journal:  Radiology       Date:  1992-07       Impact factor: 11.105

2.  Distribution of pressures and forces on the wrist after simulated intercarpal fusion and Kienböck's disease.

Authors:  W H Short; F W Werner; M D Fortino; A K Palmer
Journal:  J Hand Surg Am       Date:  1992-05       Impact factor: 2.230

3.  Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support.

Authors:  Paul A Harris; Robert Taylor; Robert Thielke; Jonathon Payne; Nathaniel Gonzalez; Jose G Conde
Journal:  J Biomed Inform       Date:  2008-09-30       Impact factor: 6.317

4.  Evaluation of healed Colles' fractures.

Authors:  J J GARTLAND; C W WERLEY
Journal:  J Bone Joint Surg Am       Date:  1951-10       Impact factor: 5.284

5.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

6.  Colles fracture: does the anatomical result affect the final function?

Authors:  M McQueen; J Caspers
Journal:  J Bone Joint Surg Br       Date:  1988-08

7.  Fracture of the distal radius. A prospective comparison between trans-styloid and Kapandji fixations.

Authors:  E Lenoble; C Dumontier; D Goutallier; A Apoil
Journal:  J Bone Joint Surg Br       Date:  1995-07

8.  Radiographic evaluation of osseous displacement following intra-articular fractures of the distal radius: reliability of plain radiography versus computed tomography.

Authors:  R J Cole; R R Bindra; B A Evanoff; L A Gilula; K Yamaguchi; R H Gelberman
Journal:  J Hand Surg Am       Date:  1997-09       Impact factor: 2.230

9.  Fractures of the distal radius. Intermediate and end results in relation to radiologic parameters.

Authors:  M Porter; I Stockley
Journal:  Clin Orthop Relat Res       Date:  1987-07       Impact factor: 4.176

10.  Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

View more
  15 in total

1.  Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction.

Authors:  Eric G Huish; John G Coury; Mohamed A Ibrahim; Marc A Trzeciak
Journal:  Hand (N Y)       Date:  2017-04-12

2.  Prospective study of comminuted articular distal radius fractures stabilized by volar plating in the elderly.

Authors:  Daniel Martinez-Mendez; Alejandro Lizaur-Utrilla; Joaquin de Juan-Herrero
Journal:  Int Orthop       Date:  2018-04-07       Impact factor: 3.075

3.  Volar Locking Plate Fixations for Displaced Distal Radius Fractures: An Evaluation of Complications and Radiographic Outcomes.

Authors:  James Wilson; Jeremy J Viner; Kavan S Johal; Michael J Woodruff
Journal:  Hand (N Y)       Date:  2017-07-09

4.  Outcomes of Open Reduction and Internal Fixation of Bilateral Fractures of the Distal Radius.

Authors:  Jack G Graham; Sreeram Penna; Daniel Fletcher; Moody Kwok; Daren J Aita; T Robert Takei; Pedro K Beredjiklian
Journal:  J Hand Microsurg       Date:  2019-05-26

5.  Simultaneous Fractures of the Ipsilateral Scaphoid and Distal Radius.

Authors:  Timothy P Fowler; Elizabeth Fitzpatrick
Journal:  J Wrist Surg       Date:  2018-04-10

6.  Dorsal Plate Osteosynthesis in Simple and Complex Fractures of the Distal Radius: A Radiological Analysis of 166 Cases.

Authors:  Haval Ghafoor; Mathias Haefeli; Regula Steiger; Philipp Honigmann
Journal:  J Wrist Surg       Date:  2021-10-01

Review 7.  A structured review addressing the use of radiographic measures of alignment and the definition of acceptability in patients with distal radius fractures.

Authors:  Emily A Lalone; Ruby Grewal; Graham J W King; Joy C MacDermid
Journal:  Hand (N Y)       Date:  2015-07-09

8.  Radiographic assessment of ligamentous injuries in distal radius fractures after open reduction and internal fixation.

Authors:  Sanjay Naran; Yaron Zaulan; Sameer Shakir; Louis A Gilula; Frederick W Werner; Ronit Wollstein
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-12-04

9.  The importance of radiological results in distal radius fracture operations: Functional outcome after long-term (6.5 years) follow-up.

Authors:  L Raudasoja; H Vastamäki; T Raatikainen
Journal:  SAGE Open Med       Date:  2018-05-22

10.  Biomechanical comparison of osteoporotic distal radius fractures fixed by distal locking screws with different length.

Authors:  Xiong Liu; Wei-dong Wu; Ya-feng Fang; Mei-chao Zhang; Wen-hua Huang
Journal:  PLoS One       Date:  2014-07-31       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.