Literature DB >> 23217631

Optimization of the reconstruction interval in neurovascular 4D-CTA imaging. A technical note.

T C H Hoogenboom1, R M J van Beurden, B van Teylingen, B Schenk, P W A Willems.   

Abstract

Time resolved whole brain CT angiography (4D-CTA) is a novel imaging technology providing information regarding blood flow. One of the factors that influence the diagnostic value of this examination is the temporal resolution, which is affected by the gantry rotation speed during acquisition and the reconstruction interval during post-processing. Post-processing determines the time spacing between two reconstructed volumes and, unlike rotation speed, does not affect radiation burden. The data sets of six patients who underwent a cranial 4D-CTA were used for this study. Raw data was acquired using a 320-slice scanner with a rotation speed of 2 Hz. The arterial to venous passage of an intravenous contrast bolus was captured during a 15 s continuous scan. The raw data was reconstructed using four different reconstruction-intervals: 0.2, 0.3, 0.5 and 1.0 s. The results were rated by two observers using a standardized score sheet. The appearance of each lesion was rated correctly in all readings. Scoring for quality of temporal resolution revealed a stepwise improvement from the 1.0 s interval to the 0.3 s interval, while no discernable improvement was noted between the 0.3 s and 0.2 s interval. An increase in temporal resolution may improve the diagnostic quality of cranial 4D-CTA. Using a rotation speed of 0.5 s, the optimal reconstruction interval appears to be 0.3 s, beyond which, changes can no longer be discerned.

Entities:  

Mesh:

Year:  2012        PMID: 23217631      PMCID: PMC3520550          DOI: 10.1177/159101991201800402

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  8 in total

1.  Neuroimaging by 320-row CT: is there a diagnostic benefit or is it just another scanner? A retrospective evaluation of 60 consecutive acute neurological patients.

Authors:  Eberhard Siebert; Georg Bohner; Florian Masuhr; Katrin Deuschle; Susanne Diekmann; Edzard Wiener; Hans-Christian Bauknecht; Randolf Klingebiel
Journal:  Neurol Sci       Date:  2010-05-28       Impact factor: 3.307

2.  Detection and classification of cranial dural arteriovenous fistulas using 4D-CT angiography: initial experience.

Authors:  P W A Willems; P A Brouwer; J J Barfett; K G terBrugge; T Krings
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

3.  A proposed grading system for arteriovenous malformations.

Authors:  R F Spetzler; N A Martin
Journal:  J Neurosurg       Date:  1986-10       Impact factor: 5.115

4.  Dynamic 320-section CT angiography in cranial arteriovenous shunting lesions.

Authors:  P A Brouwer; T Bosman; M A A van Walderveen; T Krings; A A Leroux; P W A Willems
Journal:  AJNR Am J Neuroradiol       Date:  2009-10-29       Impact factor: 3.825

5.  320-slice CT neuroimaging: initial clinical experience and image quality evaluation.

Authors:  E Siebert; G Bohner; M Dewey; F Masuhr; K T Hoffmann; J Mews; F Engelken; H C Bauknecht; S Diekmann; R Klingebiel
Journal:  Br J Radiol       Date:  2009-02-16       Impact factor: 3.039

6.  A proposed classification for spinal and cranial dural arteriovenous fistulous malformations and implications for treatment.

Authors:  J A Borden; J K Wu; W A Shucart
Journal:  J Neurosurg       Date:  1995-02       Impact factor: 5.115

7.  The use of 4D-CTA in the diagnostic work-up of brain arteriovenous malformations.

Authors:  Peter W A Willems; Patamintita Taeshineetanakul; Barry Schenk; Patrick A Brouwer; Karel G Terbrugge; Timo Krings
Journal:  Neuroradiology       Date:  2011-04-05       Impact factor: 2.804

8.  An investigation of temporal resolution parameters in cine-mode four-dimensional computed tomography acquisition.

Authors:  Yildirim D Mutaf; Debra H Brinkmann
Journal:  J Appl Clin Med Phys       Date:  2008-10-29       Impact factor: 2.102

  8 in total
  6 in total

1.  Flow diversion in the treatment of carotid injury and carotid-cavernous fistula after transsphenoidal surgery.

Authors:  Daniela Iancu; Cheemum Lum; Muhammad E Ahmed; Rafael Glikstein; Marlise P Dos Santos; Howard Lesiuk; Mohamed Labib; Amin B Kassam
Journal:  Interv Neuroradiol       Date:  2015-05-26       Impact factor: 1.610

2.  Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

Authors:  Zebin Xiao; Yingyan Zheng; Jian Li; Dehua Chen; Fang Liu; Dairong Cao
Journal:  Dentomaxillofac Radiol       Date:  2017-10-10       Impact factor: 2.419

Review 3.  4D-CTA in neurovascular disease: a review.

Authors:  H G J Kortman; E J Smit; M T H Oei; R Manniesing; M Prokop; F J A Meijer
Journal:  AJNR Am J Neuroradiol       Date:  2014-10-29       Impact factor: 3.825

Review 4.  Stereotactic radiosurgery planning based on time-resolved CTA for arteriovenous malformation: a case report and review of the literature.

Authors:  Ryan C Turner; Brandon P Lucke-Wold; Darnell Josiah; Javier Gonzalez; Matthew Schmidt; Abdul Rahman Tarabishy; Sanjay Bhatia
Journal:  Acta Neurochir (Wien)       Date:  2016-06-23       Impact factor: 2.216

5.  High sensitivity and specificity of 4D-CTA in the detection of cranial arteriovenous shunts.

Authors:  Matthijs In 't Veld; Rolf Fronczek; Marlise P Dos Santos; Marianne A A van Walderveen; Frederick J A Meijer; Peter W A Willems
Journal:  Eur Radiol       Date:  2019-05-14       Impact factor: 5.315

6.  Arteriovenous Malformations Treated With Frameless Robotic Radiosurgery Using Non-Invasive Angiography: Long-Term Outcomes of a Single Center Pilot Study.

Authors:  Ryan Kelly; Anthony Conte; M Nathan Nair; Jean-Marc Voyadzis; Amjad Anaizi; Sean Collins; Christopher Kalhorn; Andrew Stemer; Jeffery Mai; Rocco Armonda; Jonathan Lischalk; Frank Berkowitz; Vikram Nayar; Kevin McGrail; Brian Timothy Collins
Journal:  Front Oncol       Date:  2020-11-30       Impact factor: 6.244

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.