Literature DB >> 19221186

320-slice CT neuroimaging: initial clinical experience and image quality evaluation.

E Siebert1, G Bohner, M Dewey, F Masuhr, K T Hoffmann, J Mews, F Engelken, H C Bauknecht, S Diekmann, R Klingebiel.   

Abstract

The aim of this study was to report initial clinical experience with a 320-slice CT scanner and to perform an image quality evaluation. 26 patients with presumptive cerebrovascular pathology underwent 320-slice CT. Single-rotation CT of the head, incremental CT angiography (three-dimensional (3D) CTA) as well as four-dimensional whole-brain CTA (4D CTA) and whole-brain CT perfusion (CTP) were performed and the resulting images were assessed for quality and compared with those obtained with 64-slice CT protocols. 320-slice CT neuroimaging could be performed in all cases. The image quality of 320-slice CT of the head and 3D CTA was inferior to that of the 64-slice protocols. The image quality of 4D 320-slice CTA was rated as inferior to both 320- and 64-slice 3D CTA. 4D CTA-CTP imaging added information with pivotal clinical implications. 320-slice CT neuroimaging is feasible technique that permits whole-brain 4D imaging and has the potential to identify pathologies with altered haemodynamics. However, image quality is a limitation of this technique at present.

Entities:  

Mesh:

Year:  2009        PMID: 19221186     DOI: 10.1259/bjr/27721218

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  43 in total

Review 1.  Intracranial dural arteriovenous fistulas: classification, imaging findings, and treatment.

Authors:  D Gandhi; J Chen; M Pearl; J Huang; J J Gemmete; S Kathuria
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-12       Impact factor: 3.825

Review 2.  Systematic review of methods for assessing leptomeningeal collateral flow.

Authors:  F McVerry; D S Liebeskind; K W Muir
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-01       Impact factor: 3.825

3.  Neuroimaging by 320-row CT: is there a diagnostic benefit or is it just another scanner? A retrospective evaluation of 60 consecutive acute neurological patients.

Authors:  Eberhard Siebert; Georg Bohner; Florian Masuhr; Katrin Deuschle; Susanne Diekmann; Edzard Wiener; Hans-Christian Bauknecht; Randolf Klingebiel
Journal:  Neurol Sci       Date:  2010-05-28       Impact factor: 3.307

4.  Surgical treatment for ruptured dural arteriovenous fistula with large intracranial hematoma.

Authors:  Xianwang Ye; Haifeng Wang; Yi Huang; Shengjun Zhou; Xiang Gao
Journal:  Int J Clin Exp Med       Date:  2014-12-15

5.  Radiation doses of cerebral blood volume measurements using C-arm CT: A phantom study.

Authors:  W F Chu; C J Lin; W S Chen; S C Hung; C F Chiu; T H Wu; W Y Guo
Journal:  AJNR Am J Neuroradiol       Date:  2013-12-26       Impact factor: 3.825

6.  Dynamic CT angiography and CT perfusion employing a 320-detector row CT: protocol and current clinical applications.

Authors:  Eric J Salomon; Joe Barfett; Peter W A Willems; Sasikhan Geibprasert; Susanna Bacigaluppi; Timo Krings
Journal:  Klin Neuroradiol       Date:  2009-08-23

7.  Measurement of cerebral circulation times using dynamic whole-brain CT-angiography: feasibility and initial experience.

Authors:  Eberhard Siebert; Susanne Diekmann; Florian Masuhr; Hans-Christian Bauknecht; Stephan Schreiber; Randolf Klingebiel; Georg Bohner
Journal:  Neurol Sci       Date:  2011-09-22       Impact factor: 3.307

8.  Optimization of the reconstruction interval in neurovascular 4D-CTA imaging. A technical note.

Authors:  T C H Hoogenboom; R M J van Beurden; B van Teylingen; B Schenk; P W A Willems
Journal:  Interv Neuroradiol       Date:  2012-12-03       Impact factor: 1.610

9.  Whole-brain CT digital subtraction angiography of cerebral dural arteriovenous fistula using 320-detector row CT.

Authors:  Hirokazu Fujiwara; Suketaka Momoshima; Takenori Akiyama; Sachio Kuribayashi
Journal:  Neuroradiology       Date:  2013-04-16       Impact factor: 2.804

10.  Assessing regional cerebral blood flow in depression using 320-slice computed tomography.

Authors:  Yiming Wang; Hongming Zhang; Songlin Tang; Xingde Liu; Adrienne O'Neil; Alyna Turner; Fangxian Chai; Fanying Chen; Michael Berk
Journal:  PLoS One       Date:  2014-09-24       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.