Literature DB >> 23212302

Intraoperative forces and moments analysis on patient head clamp during awake brain surgery.

Danilo De Lorenzo1, Elena De Momi, Lorenzo Conti, Emiliano Votta, Marco Riva, Enrica Fava, Lorenzo Bello, Giancarlo Ferrigno.   

Abstract

In brain surgery procedures, such as deep brain stimulation, drug-resistant epilepsy and tumour surgery, the patient is intentionally awakened to map functional neural bases via electrophysiological assessment. This assessment can involve patient's body movements; thus, increasing the mechanical load on the head-restraint systems used for keeping the skull still during the surgery. The loads exchanged between the head and the restraining device can potentially result into skin and bone damage. The aim of this work is to assess such loads for laying down the requirements of a surgical robotics system for dynamic head movements compensation by fast moving arms and by an active restraint able to damp such actions. A Mayfield(®) head clamp was tracked and instrumented with strain gages (SGs). SG locations were chosen according to finite element analyses. During an actual brain surgery, displacements and strains were measured and clustered according to events that generated them. Loads were inferred from strain data. The greatest force components were exerted vertically (median 5.5 N, maximum 151.87 N) with frequencies up to 1.5 Hz. Maximum measured displacement and velocity were 9 mm and 60 mm/s, with frequencies up to 2.8 Hz. The analysis of loads and displacements allowed to identify the surgery steps causing maximal loads on the head-restraint device.

Entities:  

Mesh:

Year:  2012        PMID: 23212302     DOI: 10.1007/s11517-012-1002-9

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  19 in total

1.  Apparatus to measure simultaneously 14 isometric leg joint moments. Part 1: Design and calibration of six-axis transducers for the forces and moments at the ankle.

Authors:  N N Donaldson; M Munih; T A Perkins; D E Wood
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

2.  Neck muscle strength across the sagittal and coronal planes: an isometric study.

Authors:  Kok-Yong Seng; Vee-Sin Lee Peter; Pin-Min Lam
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002-08       Impact factor: 2.063

3.  Technique for the evaluation of derivatives from noisy biomechanical displacement data using a model-based bandwidth-selection procedure.

Authors:  M D'Amico; G Ferrigno
Journal:  Med Biol Eng Comput       Date:  1990-09       Impact factor: 2.602

4.  Risks and benefits of patient positioning during neurosurgical care.

Authors:  Irene Rozet; Monica S Vavilala
Journal:  Anesthesiol Clin       Date:  2007-09

5.  Cervical muscle strength measurement is dependent on the location of thoracic support.

Authors:  A Rezasoltani; J Ylinen; A-H Bakhtiary; M Norozi; M Montazeri
Journal:  Br J Sports Med       Date:  2007-12-10       Impact factor: 13.800

6.  Force measurement on fracture site with external fixation.

Authors:  Z G Wang; C L Peng; X L Zheng; P Wang; G R Wang
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

Review 7.  Intraoperative electrical stimulation in awake craniotomy: methodological aspects of current practice.

Authors:  Andrea Szelényi; Lorenzo Bello; Hugues Duffau; Enrica Fava; Guenther C Feigl; Miroslav Galanda; Georg Neuloh; Francesco Signorelli; Francesco Sala
Journal:  Neurosurg Focus       Date:  2010-02       Impact factor: 4.047

Review 8.  Microelectrode recording and stimulation techniques during stereotactic procedures in the thalamus and pallidum.

Authors:  A S Mandir; L H Rowland; P M Dougherty; F A Lenz
Journal:  Adv Neurol       Date:  1997

9.  The kinematic architecture of the Active Headframe: A new head support for awake brain surgery.

Authors:  Matteo Malosio; Simone Pio Negri; Nicola Pedrocchi; Federico Vicentini; Francesco Cardinale; Lorenzo Molinari Tosatti
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

10.  Force feedback in a piezoelectric linear actuator for neurosurgery.

Authors:  Danilo De Lorenzo; Elena De Momi; Ilya Dyagilev; Rudy Manganelli; Alessandro Formaglio; Domenico Prattichizzo; Moshe Shoham; Giancarlo Ferrigno
Journal:  Int J Med Robot       Date:  2011-04-28       Impact factor: 2.547

View more
  3 in total

1.  Hand-tool-tissue interaction forces in neurosurgery for haptic rendering.

Authors:  Marco Aggravi; Elena De Momi; Francesco DiMeco; Francesco Cardinale; Giuseppe Casaceli; Marco Riva; Giancarlo Ferrigno; Domenico Prattichizzo
Journal:  Med Biol Eng Comput       Date:  2015-12-31       Impact factor: 2.602

2.  Radiolucent Skull Clamps for Intra-Operative Imaging: A Technical Note.

Authors:  Neil Haranhalli; Hugo Zeberg; Patrick Lasala; David Altschul
Journal:  Cureus       Date:  2017-02-10

3.  3D intra-operative ultrasound and MR image guidance: pursuing an ultrasound-based management of brainshift to enhance neuronavigation.

Authors:  Marco Riva; Christoph Hennersperger; Fausto Milletari; Amin Katouzian; Federico Pessina; Benjamin Gutierrez-Becker; Antonella Castellano; Nassir Navab; Lorenzo Bello
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-04-08       Impact factor: 2.924

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.