Literature DB >> 10396816

Apparatus to measure simultaneously 14 isometric leg joint moments. Part 1: Design and calibration of six-axis transducers for the forces and moments at the ankle.

N N Donaldson1, M Munih, T A Perkins, D E Wood.   

Abstract

An apparatus has been developed for making isometric measurements of the joint moments corresponding to the 14 degrees of freedom of the legs, in postures ranging between sitting and near full extension. The apparatus is called the multi-moment chair system (MMCS) and is described in the companion paper. This paper describes the most critical components of the MMCS, which are the six-axis transducers for measuring the force and moment components on the plantar-flexion axis of each ankle while the feet are laced into fixed shoes. The transducers are made of steel bars, on which strain gauges are mounted, joined by clamps. The design of the transducer and methods of calibration and error estimation are described. The RMS errors are less than 2 N for the forces and 1 Nm for the moments, but these may be correlated. A method for error reduction that compensates for the finite compliance of the transducer does not reduce the measured errors.

Entities:  

Mesh:

Year:  1999        PMID: 10396816     DOI: 10.1007/bf02513280

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  5 in total

1.  Apparatus to measure simultaneously 14 isometric leg joint moments. Part 2: Multi-moment chair system.

Authors:  D E Wood; N N Donaldson; T A Perkins
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

2.  Electrical splinting of the knee in paraplegia.

Authors:  G S Brindley; C E Polkey; D N Rushton
Journal:  Paraplegia       Date:  1979-02

3.  The first 500 sacral anterior root stimulators: implant failures and their repair.

Authors:  G S Brindley
Journal:  Paraplegia       Date:  1995-01

4.  First implantation of a 16-channel electric stimulation device in the human body.

Authors:  H Thoma; M Frey; H Gruber; J Holle; H Kern; E Reiner; G Schwanda; H Stöhr
Journal:  Trans Am Soc Artif Intern Organs       Date:  1983

5.  Determination of the segmental sensory and motor innervation of the lumbosacral spinal nerves. An electrophysiological study.

Authors:  R Liguori; C Krarup; W Trojaborg
Journal:  Brain       Date:  1992-06       Impact factor: 13.501

  5 in total
  2 in total

1.  Apparatus to measure simultaneously 14 isometric leg joint moments. Part 2: Multi-moment chair system.

Authors:  D E Wood; N N Donaldson; T A Perkins
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

2.  Intraoperative forces and moments analysis on patient head clamp during awake brain surgery.

Authors:  Danilo De Lorenzo; Elena De Momi; Lorenzo Conti; Emiliano Votta; Marco Riva; Enrica Fava; Lorenzo Bello; Giancarlo Ferrigno
Journal:  Med Biol Eng Comput       Date:  2012-12-02       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.