Flow velocity estimation by complex ambiguity free joint Spectral and Time domain Optical Coherence Tomography.

Maciej Szkulmowski1, Ireneusz Grulkowski, Daniel Szlag, Anna Szkulmowska, Andrzej Kowalczyk, Maciej Wojtkowski.   

Abstract

We show that recently introduced joint Spectral and Time domain Optical Coherence Tomography (STdOCT) can be used for simultaneous complex ambiguity removal and functional Spectral OCT images. This permits to take advantage of higher sensitivity achievable near the zero-path delay. The technique can be used with all Spectral OCT systems that are equipped with an optical delay line (ODL) and provide oversampled scanning patterns. High sensitivity provided by STdOCT allows this technique to be used in Spectral OCT setups with acquisition speed of 100,000 lines/s. We show that different imaging ranges and velocity ranges can be achieved by switching on/off the ODL and a small modification in the processing algorithm. Additionally, the relatively small computational burden of the technique allows for fast computations in the range of less than 5 minutes for 3D data set. We present application of proposed technique to full-range two- and three-dimensional imaging. Morphological and Doppler tomograms of human retina in-vivo are shown. Finally, we identify and discuss artifacts of the technique.

Entities:  

Mesh:

Year:  2009        PMID: 19654837     DOI: 10.1364/oe.17.014281

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  17 in total

1.  Comparison of phase-shifting techniques for in vivo full-range, high-speed Fourier-domain optical coherence tomography.

Authors:  Dae Yu Kim; John S Werner; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2010 Sep-Oct       Impact factor: 3.170

2.  OCT angiography by absolute intensity difference applied to normal and diseased human retinas.

Authors:  Daniel Ruminski; Bartosz L Sikorski; Danuta Bukowska; Maciej Szkulmowski; Krzysztof Krawiec; Grazyna Malukiewicz; Lech Bieganowski; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2015-07-06       Impact factor: 3.732

3.  Autocorrelation optical coherence tomography for mapping transverse particle-flow velocity.

Authors:  Yi Wang; Ruikang Wang
Journal:  Opt Lett       Date:  2010-11-01       Impact factor: 3.776

4.  Phase-sensitive optical coherence tomography using an Vernier-tuned distributed Bragg reflector swept laser in the mouse middle ear.

Authors:  Jesung Park; Esteban F Carbajal; Xi Chen; John S Oghalai; Brian E Applegate
Journal:  Opt Lett       Date:  2014-11-01       Impact factor: 3.776

5.  Spectrometer calibration for spectroscopic Fourier domain optical coherence tomography.

Authors:  Maciej Szkulmowski; Szymon Tamborski; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2016-11-09       Impact factor: 3.732

Review 6.  Optical coherence tomography based angiography [Invited].

Authors:  Chieh-Li Chen; Ruikang K Wang
Journal:  Biomed Opt Express       Date:  2017-01-24       Impact factor: 3.732

7.  Complex conjugate artifact-free adaptive optics optical coherence tomography of in vivo human optic nerve head.

Authors:  Dae Yu Kim; John S Werner; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2012-12       Impact factor: 3.170

8.  High-speed spectral calibration by complex FIR filter in phase-sensitive optical coherence tomography.

Authors:  Sangmin Kim; Patrick D Raphael; John S Oghalai; Brian E Applegate
Journal:  Biomed Opt Express       Date:  2016-03-21       Impact factor: 3.732

9.  Photothermal optical lock-in optical coherence tomography for in vivo imaging.

Authors:  Jason M Tucker-Schwartz; Maryse Lapierre-Landry; Chetan A Patil; Melissa C Skala
Journal:  Biomed Opt Express       Date:  2015-05-27       Impact factor: 3.732

10.  Full range complex ultrahigh sensitive optical microangiography.

Authors:  Lin An; Ruikang K Wang
Journal:  Opt Lett       Date:  2011-03-15       Impact factor: 3.776

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.