Literature DB >> 23196677

Accurate localization of incidental findings on the computed tomography attenuation correction image: the influence of tube current variation.

John Thompson1, Peter Hogg, Samantha Higham, David Manning.   

Abstract

This observer performance study assessed lesion detection in the computed tomography attenuation correction image, as would be produced for myocardial perfusion imaging over a tube current (mA) range. A static anthropomorphic chest phantom containing simulated pulmonary lesions was scanned using the four available mA values (1, 1.5, 2 and 2.5) on a GE Infinia Hawkeye 4. All other computed tomography acquisition parameters remained constant throughout. Twenty-seven cases showing zero to four lesions were produced for a free-response receiver-operating characteristic method. Image observations were completed using our novel web-based ROCView software under controlled conditions. The Jackknife alternative free-response receiver-operating characteristic (JAFROC) figure of merit was used for significance testing, wherein a difference in lesion detection performance was considered significant at P values less than 0.05. Twenty readers with varying computed tomography experience (0-24 years) evaluated 108 images using an ordinal scale to score confidence. The JAFROC analysis showed that there was no statistically significant difference in performance between mA values (P=0.439) for this sample of observers. In conclusion, no significant difference in lesion detection performance was seen between the mA values. This suggests that there is no value in using anything other than the lowest mA value for the investigation of incidental extracardiac findings.

Entities:  

Mesh:

Year:  2013        PMID: 23196677     DOI: 10.1097/MNM.0b013e32835c0984

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  3 in total

1.  Blurred digital mammography images: an analysis of technical recall and observer detection performance.

Authors:  Wang Kei Ma; Rita Borgen; Judith Kelly; Sara Millington; Beverley Hilton; Rob Aspin; Carla Lança; Peter Hogg
Journal:  Br J Radiol       Date:  2017-01-30       Impact factor: 3.039

2.  Comparison of effective dose and lifetime risk of cancer incidence of CT attenuation correction acquisitions and radiopharmaceutical administration for myocardial perfusion imaging.

Authors:  A K Tootell; K Szczepura; P Hogg
Journal:  Br J Radiol       Date:  2014-07-07       Impact factor: 3.039

3.  A free-response evaluation determining value in the computed tomography attenuation correction image for revealing pulmonary incidental findings: a phantom study.

Authors:  John D Thompson; Peter Hogg; David J Manning; Katy Szczepura; Dev P Chakraborty
Journal:  Acad Radiol       Date:  2014-04       Impact factor: 3.173

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.