Literature DB >> 23180011

Diagrams for the Leksell Gamma Knife 4C automatic positioning system accessible shot coordinates.

Yoichi Watanabe1.   

Abstract

We have developed a graphic representation (APS shot-range diagrams) of achievable shot coordinates with the automatic positioning system (APS) for Gamma Knife stereotactic radiosurgery. We formulated a mathematical relationship between the APS coordinate system and the Leksell frame coordinate system (frame-system) by considering the relative translation and rotation. Using the transformation equations, we calculated the Y-Z coordinate domain in the frame-system (domain B), which corresponds to the known coordinate domain achievable in the APS coordinate system (domain A). APS shot-range diagrams were presented by overlaying of domain B over domain A so that one can easily visualize the achievable shot coordinates with APS for various gamma angles. Domains A and B are identical for a 90° gamma angle, but they are different for other gamma angles. Applications of the diagrams to clinical cases, in which Leksell GammaPlan treatment planning software automatically set some of the shots in a treatment plan as trunnion shots because of the APS coordinate limit, enabled us to avoid the trunnion shots, and consequently to achieve much faster treatment delivery. In conclusion, APS shot-range diagrams can be used for achieving more efficient treatment delivery by avoiding unnecessary trunnion shots with a Gamma Knife unit equipped with the APS.

Entities:  

Mesh:

Year:  2012        PMID: 23180011     DOI: 10.1007/s12194-012-0188-8

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  5 in total

1.  First clinical experience with the automatic positioning system and Leksell gamma knife Model C. Technical note.

Authors:  G A Horstmann; H Schöpgens; A T van Eck; H J Kreiner; W Herz
Journal:  J Neurosurg       Date:  2000-12       Impact factor: 5.115

2.  Risk analysis of Leksell Gamma Knife Model C with automatic positioning system.

Authors:  Steven J Goetsch
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-03-01       Impact factor: 7.038

3.  A comparison of the gamma knife model C and the automatic positioning system with Leksell model B.

Authors:  Daniela Tlachacova; Michal Schmitt; Josef Novotny; Josef Novotny; Mustafa Majali; Roman Liscak
Journal:  J Neurosurg       Date:  2005-01       Impact factor: 5.115

4.  Use of the Leksell gamma knife C with automatic positioning system for the treatment of meningioma and vestibular schwannoma.

Authors:  Marc Levivier; Jose Lorenzoni; Nicolas Massager; Salvador Ruiz; Daniel Devriendt; Jacques Brotchi
Journal:  Neurosurg Focus       Date:  2003-05-15       Impact factor: 4.047

5.  Impact of the model C and Automatic Positioning System on gamma knife radiosurgery: an evaluation in vestibular schwannomas.

Authors:  Jean Régis; Motohiro Hayashi; Denis Porcheron; Christine Delsanti; Xavier Muracciole; Jean Claude Peragut
Journal:  J Neurosurg       Date:  2002-12       Impact factor: 5.115

  5 in total
  1 in total

1.  Effective usage of a clearance check to avoid a collision in Gamma Knife Perfexion radiosurgery with the Leksell skull frame.

Authors:  Hisato Nakazawa; Takahiko Tsugawa; Yoshimasa Mori; Masahiro Hagiwara; Masataka Komori; Chisa Hashizume; Yuta Shibamoto; Tatsuya Kobayashi
Journal:  J Radiat Res       Date:  2014-06-24       Impact factor: 2.724

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.