Literature DB >> 11143247

First clinical experience with the automatic positioning system and Leksell gamma knife Model C. Technical note.

G A Horstmann1, H Schöpgens, A T van Eck, H J Kreiner, W Herz.   

Abstract

In May of 1999, the first Leksell Model C gamma knife was installed at the Gamma Knife Zentrum in Krefeld, Germany. The authors recount their experience with this latest technical gamma knife development. Until the end of 1999, extensive physical and technical tests were performed and the system's hardware and software were continuously improved and adapted to the user's needs. By the end of 1999, 163 GKSs had been performed using the new functionality of the Model C in manual or "trunnion" mode. The trunnions, the two parts of the system that fix the patient headframe to the gamma knife when the isocenter positions, are checked manually. During the same period the new automatic positioning system (APS) was extensively tested and refined so that the first APS treatment could be performed in January 2000. Fifty GKSs have been performed with the APS capability of the Model C. It was possible to use APS alone in 74% of surgeries whereas in 14% some shots were given with APS and some with trunnions. In 12%, GKS was scheduled and planned for APS, but due to unexpected technical (6%) or mechanical (6%) reasons the treatment had to be performed manually. At present there are some spatial restrictions with Model C in APS mode when compared with the Model B. The most significant restriction is the narrow space for the patient's shoulders, especially when deep-seated lesions are treated. Through mechanical changes of the APS motor housing and some modifications of and to the motor driven couch adjustment, these limitations will be reduced in the future. The APS treatment runs smoothly and fast. In no case did any relevant safety error occur during GKS. The more stringent mechanical limitations of the APS compared with the Model B means that frame placement on the head is more critical than before.

Entities:  

Mesh:

Year:  2000        PMID: 11143247     DOI: 10.3171/jns.2000.93.supplement

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  4 in total

1.  Diagrams for the Leksell Gamma Knife 4C automatic positioning system accessible shot coordinates.

Authors:  Yoichi Watanabe
Journal:  Radiol Phys Technol       Date:  2012-11-18

2.  Simulated gamma knife head frame placement for radiosurgical pre-planning.

Authors:  D Wiant; J D Bourland
Journal:  Technol Cancer Res Treat       Date:  2009-08

3.  Impact of decaying dose rate in gamma knife radiosurgery: in vitro study on 9L rat gliosarcoma cells.

Authors:  Ajay Niranjan; Glenn Gobbel; Josef Novotny; Jagdish Bhatnagar; Wendy Fellows; L Dade Lunsford
Journal:  J Radiosurg SBRT       Date:  2012

4.  First year experience with newly developed Leksell Gamma Knife Perfexion.

Authors:  Jagdish P Bhatnagar; Josef Novotny; Ajay Niranjan; Douglas Kondziolka; John Flickinger; Dade Lunsford; M Saiful Huq
Journal:  J Med Phys       Date:  2009-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.