Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses.

David A Boone1, Toshiki Kobayashi, Teri G Chou, Adam K Arabian, Kim L Coleman, Michael S Orendurff, Ming Zhang.   

Abstract

Alignment - the process and measured orientation of the prosthetic socket relative to the foot - is important for proper function of a transtibial prosthesis. Prosthetic alignment is performed by prosthetists using visual gait observation and amputees' feedback. The aim of this study was to investigate the effect of transtibial prosthesis malalignment on the moments measured at the base of the socket: the socket reaction moments. Eleven subjects with transtibial amputation were recruited from the community. An instrumented prosthesis alignment component was used to measure socket reaction moments during ambulation under 17 alignment conditions, including nominally aligned using conventional clinical methods, and angle perturbations of 3° and 6° (flexion, extension, abduction, and adduction) and translation perturbations of 5mm and 10mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. Coronal alignment perturbations caused systematic changes in the coronal socket reaction moments. All angle and translation perturbations revealed statistically significant differences on coronal socket reaction moments compared to the nominal alignment at 30% and 75% of stance phase (P<0.05). The effect of sagittal alignment perturbations on sagittal socket reaction moments was not as responsive as that of the coronal perturbations. The sagittal angle and translation perturbations of the socket led to statistically significant changes in minimum moment, maximum moment, and moments at 45% of stance phase in the sagittal plane. Therefore, malalignment affected the socket reaction moments in amputees with transtibial prostheses.
Copyright © 2012 Elsevier B.V. All rights reserved.

Mesh:

Year:  2012        PMID: 23177920     DOI: 10.1016/j.gaitpost.2012.10.002

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  11 in total

1.  The effects of alignment of an articulated ankle-foot orthosis on lower limb joint kinematics and kinetics during gait in individuals post-stroke.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Grace Hunt; Fan Gao; Nicholas LeCursi; Lucas S Lincoln; K Bo Foreman
Journal:  J Biomech       Date:  2018-11-22       Impact factor: 2.712

2.  Sensitivity of biomechanical outcomes to independent variations of hindfoot and forefoot stiffness in foot prostheses.

Authors:  Peter Gabriel Adamczyk; Michelle Roland; Michael E Hahn
Journal:  Hum Mov Sci       Date:  2017-05-09       Impact factor: 2.161

Review 3.  A unified perspective on ankle push-off in human walking.

Authors:  Karl E Zelik; Peter G Adamczyk
Journal:  J Exp Biol       Date:  2016-12-01       Impact factor: 3.312

4.  Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Adam K Arabian; Teri G Rosenbaum-Chou; David A Boone
Journal:  J Biomech       Date:  2014-02-14       Impact factor: 2.712

5.  Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet.

Authors:  Toshiki Kobayashi; Adam K Arabian; Michael S Orendurff; Teri G Rosenbaum-Chou; David A Boone
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-11-13       Impact factor: 2.063

6.  Effect of alignment changes on socket reaction moments during gait in transfemoral and knee-disarticulation prostheses: case series.

Authors:  Toshiki Kobayashi; Michael S Orendurff; David A Boone
Journal:  J Biomech       Date:  2013-07-26       Impact factor: 2.712

7.  Stakeholder perspectives for possible residual limb monitoring system for persons with lower-limb amputation.

Authors:  Lilly Tran; Ryan Caldwell; Matthew Quigley; Stefania Fatone
Journal:  Disabil Rehabil       Date:  2018-09-05       Impact factor: 3.033

Review 8.  The Effect of Alignment Changes on Unilateral Transtibial Amputee's Gait: A Systematic Review.

Authors:  Niels Jonkergouw; Maarten R Prins; Arjan W P Buis; Peter van der Wurff
Journal:  PLoS One       Date:  2016-12-06       Impact factor: 3.240

Review 9.  Systematic Review of Studies Examining Transtibial Prosthetic Socket Pressures with Changes in Device Alignment.

Authors:  Philip Davenport; Siamak Noroozi; Philip Sewell; Saeed Zahedi
Journal:  J Med Biol Eng       Date:  2017-01-21       Impact factor: 1.553

Review 10.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.