Comparison of chest digital tomosynthesis and chest radiography for detection of asbestos-related pleuropulmonary disease.

G Lee1, Y J Jeong, K I Kim, J W Song, D M Kang, Y D Kim, J W Lee.   

Abstract

AIM: To compare chest digital tomosynthesis (DTS) with digital radiography for the detection of asbestos-related pleuropulmonary disease.
MATERIALS AND METHODS: The institutional review board approved this study and all participants gave informed consent. Forty-five participants with a history of asbestos exposure were examined with DTS and radiography. Low-dose multidetector computed tomography (CT) in the prone position served as the reference. Two observers evaluated all images for the presence of pleural abnormalities and asbestosis. Interobserver agreement was analysed by using the k statistic. Diagnostic performance of the two imaging methods was compared using McNemar's test.
RESULTS: Interobserver agreement regarding DTS findings was moderate to very good (k = 0.544-0.846) and superior to the radiographic findings (k = 0.236-1.000). Overall, the diagnostic accuracy of DTS for the lesion detection was significantly better than with radiography (all p < 0.05, except that for the comparison of diagnostic accuracy of DTS versus radiographic detection of left diaphragmatic plaques and asbestosis). DTS was more sensitive than radiography for the detection of asbestosis (82% versus 27%, p = 0.031).
CONCLUSION: DTS is more accurate than radiography in the detection of pleural plaques and more sensitive than radiography in the detection of asbestosis. Interobserver agreements with respect to the DTS findings were superior to the radiographic findings.
Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23177084     DOI: 10.1016/j.crad.2012.05.022

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  12 in total

1.  A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference.

Authors:  Ji Yung Choo; Ki Yeol Lee; Ami Yu; Je-Hyeong Kim; Seung Heon Lee; Jung Won Choi; Eun-Young Kang; Yu Whan Oh
Journal:  Eur Radiol       Date:  2015-12-11       Impact factor: 5.315

2.  Evaluation of a new system for chest tomosynthesis: aspects of image quality of different protocols determined using an anthropomorphic phantom.

Authors:  M Jadidi; A Sundin; P Aspelin; M Båth; S Nyrén
Journal:  Br J Radiol       Date:  2015-06-29       Impact factor: 3.039

3.  Effect of radiation dose level on the detectability of pulmonary nodules in chest tomosynthesis.

Authors:  Sara A Asplund; Åse A Johnsson; Jenny Vikgren; Angelica Svalkvist; Agneta Flinck; Marianne Boijsen; Valeria A Fisichella; Lars Gunnar Månsson; Magnus Båth
Journal:  Eur Radiol       Date:  2014-05-04       Impact factor: 5.315

4.  Reliability of semiquantitative assessment of osteophytes and subchondral cysts on tomosynthesis images by radiologists with different levels of expertise.

Authors:  Daichi Hayashi; Li Xu; Jeffrey Gusenburg; Frank W Roemer; David J Hunter; Ling Li; Ali Guermazi
Journal:  Diagn Interv Radiol       Date:  2014 Jul-Aug       Impact factor: 2.630

5.  Wavelet denoising for quantum noise removal in chest digital tomosynthesis.

Authors:  Tsutomu Gomi; Masahiro Nakajima; Tokuo Umeda
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-04-20       Impact factor: 2.924

6.  Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

Authors:  James T Dobbins; H Page McAdams; John M Sabol; Dev P Chakraborty; Ella A Kazerooni; Gautham P Reddy; Jenny Vikgren; Magnus Båth
Journal:  Radiology       Date:  2016-07-19       Impact factor: 11.105

7.  Dependency of image quality on acquisition protocol and image processing in chest tomosynthesis-a visual grading study based on clinical data.

Authors:  Masoud Jadidi; Magnus Båth; Sven Nyrén
Journal:  Br J Radiol       Date:  2018-04-09       Impact factor: 3.039

8.  Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study.

Authors:  Kyung Won Doo; Eun-Young Kang; Hwan Seok Yong; Soo-Youn Ham; Ki Yeol Lee; Ji Yung Choo
Journal:  Eur Radiol       Date:  2014-08-06       Impact factor: 5.315

9.  Digital tomosynthesis for evaluating metastatic lung nodules: nodule visibility, learning curves, and reading times.

Authors:  Kyung Hee Lee; Jin Mo Goo; Sang Min Lee; Chang Min Park; Young Eun Bahn; Hyungjin Kim; Yong Sub Song; Eui Jin Hwang
Journal:  Korean J Radiol       Date:  2015-02-27       Impact factor: 3.500

10.  EFFECT OF RADIATION DOSE LEVEL ON ACCURACY AND PRECISION OF MANUAL SIZE MEASUREMENTS IN CHEST TOMOSYNTHESIS EVALUATED USING SIMULATED PULMONARY NODULES.

Authors:  Christina Söderman; Åse Allansdotter Johnsson; Jenny Vikgren; Rauni Rossi Norrlund; David Molnar; Angelica Svalkvist; Lars Gunnar Månsson; Magnus Båth
Journal:  Radiat Prot Dosimetry       Date:  2016-03-17       Impact factor: 0.972