Literature DB >> 23169737

Radiation dose and image quality at high-pitch CT angiography of the aorta: intraindividual and interindividual comparisons with conventional CT angiography.

Paul Apfaltrer1, E Lexworth Hanna, U Joseph Schoepf, J Reid Spears, Stefan O Schoenberg, Christian Fink, Rozemarijn Vliegenthart.   

Abstract

OBJECTIVE: The objective of our study was to evaluate radiation dose and quantitative image quality parameters at high-pitch CT angiography (CTA) of the aorta compared with conventional CTA.
MATERIALS AND METHODS: We studied the examinations of 110 patients (65 men and 45 women; mean age ± SD, 64 ± 15 years) who had undergone CTA of the entire aorta on a second-generation dual-source CT system; 50 examinations were performed in high-pitch mode. The mean arterial attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) were calculated for the high-pitch CTA and conventional CTA groups. Radiation exposures were compared.
RESULTS: All studies were considered of diagnostic quality. At high-pitch CTA, the mean tube voltage and tube current-exposure time product were 118 ± 7 kV (SD) and 197 ± 78 mAs compared with 120 ± 1 kV and 258 ± 78 mAs, respectively, at conventional CTA (p < 0.05). The mean volume CT dose index, dose-length product, and effective dose were 8.1 ± 2.4 mGy, 561.1 ± 178.6 mGy × cm, and 9.6 ± 3.0 mSv at high-pitch CTA and 18.3 ± 7.7 mGy, 1162.6 ± 480.1 mGy × cm, and 19.8 ± 8.2 mSv at conventional CTA (p < 0.001). Attenuation was similar for both protocols, whereas significantly less contrast medium was injected for high-pitch CTA than for standard-pitch CTA (87.3 ± 16 mL vs 97.9 ± 16 mL, respectively; p < 0.01). The SNR and CNR were significantly lower in the high-pitch CTA examinations (p < 0.01), whereas the FOM was nonsignificantly higher. Twenty patients underwent both high-pitch CTA and conventional CTA, with a 45% reduction in radiation dose (p < 0.001).
CONCLUSION: High-pitch CTA of the aorta yields 45-50% reduction of radiation exposure as well as contrast medium savings with maintained vessel attenuation.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23169737     DOI: 10.2214/AJR.12.8652

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  12 in total

1.  Is ECG triggering for motion artefact reduction in dual-source CT angiography of the ascending aorta still required with high-pitch scanning? The role of ECG-gating in high-pitch dual-source CT of the ascending aorta.

Authors:  Alice Wielandner; Dietrich Beitzke; Ruediger Schernthaner; Florian Wolf; Christina Langenberger; Alfred Stadler; Christian Loewe
Journal:  Br J Radiol       Date:  2016-06-01       Impact factor: 3.039

2.  High-pitch dual-source CT angiography without ECG-gating for imaging the whole aorta: intraindividual comparison with standard pitch single-source technique without ECG gating.

Authors:  Carmelinda Manna; Mario Silva; Rocco Cobelli; Sara Poggesi; Cristina Rossi; Nicola Sverzellati
Journal:  Diagn Interv Radiol       Date:  2017 Jul-Aug       Impact factor: 2.630

3.  What the Baby Formula and Medical Contrast Material Shortages Have in Common: Insights and Recommendations for Managing the Iodinated Contrast Media Shortage.

Authors:  Lakshmi Ananthakrishnan; Fernando U Kay; Eric A Zeikus; Eugene S Chu; Joseph Chang; John D Barr; Neil M Rofsky; Suhny Abbara
Journal:  Radiol Cardiothorac Imaging       Date:  2022-05-25

4.  Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison.

Authors:  Aleksander W Krazinski; Felix G Meinel; U Joseph Schoepf; Justin R Silverman; Christian Canstein; Carlo N De Cecco; Lucas L Geyer
Journal:  Eur Radiol       Date:  2014-07-24       Impact factor: 5.315

5.  Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom.

Authors:  Domenico De Santis; Damiano Caruso; U Joseph Schoepf; Marwen Eid; Moritz H Albrecht; Taylor M Duguay; Akos Varga-Szemes; Andrea Laghi; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2018-02-27       Impact factor: 5.315

6.  Radiation Dose and Image Quality in Pediatric Cardiac Computed Tomography: A Comparison Between Sequential and Third-Generation Dual-Source High-Pitch Spiral Techniques.

Authors:  Huiliang Koh; Ching Ching Ong; Yun Song Choo; Chong Ri Liang; Grace Hui Zhen Tan; Terence Chee Wen Lim; Swee Chye Quek; Shankar Sriram; Lynette Li San Teo
Journal:  Pediatr Cardiol       Date:  2016-07-05       Impact factor: 1.655

Review 7.  Multi-detector computed tomography in the diagnosis and management of acute aortic syndromes.

Authors:  James Thomas Patrick Decourcy Hallinan; Gopinathan Anil
Journal:  World J Radiol       Date:  2014-06-28

Review 8.  Imaging of systemic vasculitis in childhood.

Authors:  Magdy Soliman; Ronald Laxer; David Manson; Rae Yeung; Andrea S Doria
Journal:  Pediatr Radiol       Date:  2015-07-22

9.  Evaluation the Aortic Aneurysm Remodeling After a Successful Stentgraft Implantation.

Authors:  Monika Nowicka; Agnieszka Kowalczyk; Grażyna Rusak; Przemysław Ratajczak; Bartosz Sobociński
Journal:  Pol J Radiol       Date:  2016-10-13

10.  High-pitch, low-voltage and low-iodine-concentration CT angiography of aorta: assessment of image quality and radiation dose with iterative reconstruction.

Authors:  Yanguang Shen; Zhonghua Sun; Lei Xu; Yu Li; Nan Zhang; Zixu Yan; Zhanming Fan
Journal:  PLoS One       Date:  2015-02-02       Impact factor: 3.240