Literature DB >> 23169715

Pulmonary 64-MDCT angiography with 30 mL of IV contrast material: vascular enhancement and image quality.

Carol C Wu1, Edward W Lee, Robert D Suh, Barton S Levine, Bruce M Barack.   

Abstract

OBJECTIVE: The objective of our study was to determine whether vascular enhancement and image quality can be preserved in pulmonary CT angiography (CTA) performed on a 64-MDCT scanner with 30 mL of IV contrast material.
MATERIALS AND METHODS: This retrospective matched-cohort study compared image quality of pulmonary CTA performed using 30 mL of IV contrast material versus 100 mL of IV contrast material. CT images of 50 patients (46 men, four women; mean age, 66 years) who underwent pulmonary CTA on a 64-MDCT scanner using a low dose (30 mL) of iodixanol 320 and another 50 patients (49 men, one woman; mean age, 65 years) who underwent pulmonary CTA using a regular dose (100 mL) of contrast material during the same time period were selected for review. The 30- and 100-mL pulmonary CTA studies were retrospectively evaluated by two thoracic radiologists in random order. Attenuation values were recorded over the main, right main, selected lobar, segmental, and subsegmental pulmonary arteries. Image quality was also subjectively assessed using visual scores on a scale from 1 (nondiagnostic) to 5 (excellent).
RESULTS: The average attenuation measurements of the main, right main, selected lobar, segmental, and subsegmental pulmonary arteries were 260, 262, 280, 316, and 338 HU, respectively, on the 30-mL studies and 313, 301, 316, 344, and 349 HU, respectively, on the 100-mL studies. The average visual score was 4.0 for both the 30- and 100-mL groups. A visual score of 4 or 5 was given to 82% of studies in the 30-mL group and 78% of studies in the 100-mL group.
CONCLUSION: Contrast agent dose for pulmonary CTA using a 64-MDCT scanner can be significantly reduced without compromising diagnostic image quality.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23169715     DOI: 10.2214/AJR.12.8739

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  11 in total

1.  High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume.

Authors:  Guang Ming Lu; Song Luo; Felix G Meinel; Andrew D McQuiston; Chang Sheng Zhou; Xiang Kong; Yan E Zhao; Ling Zheng; U Joseph Schoepf; Long Jiang Zhang
Journal:  Eur Radiol       Date:  2014-08-07       Impact factor: 5.315

2.  What the Baby Formula and Medical Contrast Material Shortages Have in Common: Insights and Recommendations for Managing the Iodinated Contrast Media Shortage.

Authors:  Lakshmi Ananthakrishnan; Fernando U Kay; Eric A Zeikus; Eugene S Chu; Joseph Chang; John D Barr; Neil M Rofsky; Suhny Abbara
Journal:  Radiol Cardiothorac Imaging       Date:  2022-05-25

3.  Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol.

Authors:  Henrique Simão Trad; Gustavo Santos Boasquevisque; Tiago Rangon Giacometti; Catherine Yang Trad; Orlando Salomão Zoghbi Neto; Clovis Simão Trad
Journal:  Radiol Bras       Date:  2016 Mar-Apr

4.  An optimised patient-specific approach to administration of contrast agent for CT pulmonary angiography.

Authors:  Charbel Saade; Roger Bourne; Fadi El-Merhi; Arjuna Somanathan; Dev Chakraborty; Patrick Brennan
Journal:  Eur Radiol       Date:  2013-06-04       Impact factor: 5.315

5.  CT angiography for pulmonary embolism in the emergency department: investigation of a protocol by 20 ml of high-concentration contrast medium.

Authors:  Mario Silva; Gianluca Milanese; Rocco Cobelli; Carmelinda Manna; Edoardo Rasciti; Sara Poggesi; Nicola Sverzellati
Journal:  Radiol Med       Date:  2019-10-28       Impact factor: 3.469

6.  Use of pulmonary CT angiography with low tube voltage and low-iodine-concentration contrast agent to diagnose pulmonary embolism.

Authors:  Xuemei Hu; Liya Ma; Jinhua Zhang; Zhen Li; Yaqi Shen; Daoyu Hu
Journal:  Sci Rep       Date:  2017-10-16       Impact factor: 4.379

7.  Minimizing contrast media dose in CT pulmonary angiography with high-pitch technique.

Authors:  Hanan Alobeidi; Muhammed Alshamari; Jonas Widell; Tomas Eriksson; Mats Lidén
Journal:  Br J Radiol       Date:  2020-05-21       Impact factor: 3.039

8.  Looking beyond the thrombus: essentials of pulmonary artery imaging on CT.

Authors:  Mohammed M Khadir; Apeksha Chaturvedi; Mike S Nguyen; John C Wandtke; Susan Hobbs; Abhishek Chaturvedi
Journal:  Insights Imaging       Date:  2014-07-08

9.  Feasibility of low contrast media volume in CT angiography of the aorta.

Authors:  Anna Seehofnerová; Madeleine Kok; Casper Mihl; Dave Douwes; Anni Sailer; Estelle Nijssen; Michiel J W de Haan; Joachim E Wildberger; Marco Das
Journal:  Eur J Radiol Open       Date:  2015-04-28

10.  Improvement of Contrast Media Enhancement in CTA Evaluating Pulmonary Embolism by Utilizing 'Delayed' Bolus Tracking in the Descending Aorta.

Authors:  Robert Damm; Konrad Mohnike; Angelos Gazis; Bela Rogits; Max Seidensticker; Jens Ricke; Maciej Pech
Journal:  Pol J Radiol       Date:  2016-09-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.