Literature DB >> 23157674

Simultaneous sinus lift and implant installation: prospective study of consecutive two hundred seventeen sinus lift and four hundred sixty-two implants.

Hyun-Suk Cha1, Andrew Kim, Hessam Nowzari, Hoo-Sun Chang, Kang-Min Ahn.   

Abstract

PURPOSE: If less than 4 mm of residual bone is remained in posterior maxilla, two-stage operation is recommended for implant installation. However, if primary stability could be obtained using tapered designed implants, one-stage surgery could be performed with reliable success rate in severely resorbed maxilla. The purpose of this prospective study was to evaluate survival and success rates of the implants simultaneously placed into grafted sinus using rough-surfaced implant.
MATERIALS AND METHODS: A total of two hundred seventeen consecutive sinus lifting through lateral approach and four hundred sixty-two simultaneous implants were installed from November 2003 for 5.5 years. Xenogenic bone was used solely for bone graft materials. Second surgery was performed around 6 months after operation and porcelain fused metal or gold crown was used for definitive restorations. Cumulative survival and success rates were evaluated according to residual alveolar bone height (RABH), smoking status, and Schneiderian membrane perforation.
RESULTS: The mean follow-up was 57.1 ± 15.6 (36-98) months. Of the four hundred sixty-two implants, two hundred sixty-two implants (56.7%: group 1) were installed in posterior maxilla less than 4-mm RABH and two hundred implants (43.3%: group 2) were placed in over 5-mm RABH. The cumulative survival and success rates were 98.91% and 96.54%. There was no statistically significant difference in success rate between group 1 and group 2 (p = .3135). Perforation of the membrane was not related to success (p = .7162), but smoking status is significantly related with implant failure (p = .0003).
CONCLUSIONS: Sinus lifting with simultaneous implant placement could be used to treat atrophic maxilla in patients with minimal RABH when initial stability could be obtained by using taper designed implants with surgical techniques. Smoking is a possible factor for implant failure. Membrane perforation did not have an adverse effect on implant success if the membrane was repaired with absorbable membrane and fibrin glue.
© 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  Schneiderian membrane; dental implant; perforation; residual alveolar bone; sinus lifting; smoking; xenogenic bone

Mesh:

Substances:

Year:  2012        PMID: 23157674     DOI: 10.1111/cid.12012

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  7 in total

1.  Evaluation of the effects of the systemic proton pump inhibitor-omeprazole on periimplant bone regeneration and osseointegration: An experimental study.

Authors:  Mehmet Gul; Serkan Dundar; Alihan Bozoglan; Erhan Cahit Ozcan; Samet Tekin; Tuba Talo Yildirim; Necmettin Karasu; Muhammet Bahattin Bingul
Journal:  J Oral Biol Craniofac Res       Date:  2022-05-10

2.  Survival rate of Astra Tech implants with maxillary sinus lift.

Authors:  Wook-Jae Yoon; Kyung-In Jeong; Jae-Seek You; Ji-Su Oh; Su-Gwan Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2014-02-25

3.  Perforation of the Schneiderian membrane during sinus floor elevation: a risk factor for long-term success of dental implants?

Authors:  Benedicta E Beck-Broichsitter; Mirko Gerle; Jörg Wiltfang; Stephan Thomas Becker
Journal:  Oral Maxillofac Surg       Date:  2020-01-30

4.  Frequency of bone graft in implant surgery.

Authors:  Hyun-Suk Cha; Ji-Wan Kim; Jong-Hyun Hwang; Kang-Min Ahn
Journal:  Maxillofac Plast Reconstr Surg       Date:  2016-03-31

5.  Impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success.

Authors:  Benedicta E Beck-Broichsitter; Dorothea Westhoff; Eleonore Behrens; Jörg Wiltfang; Stephan T Becker
Journal:  Int J Implant Dent       Date:  2018-02-05

Review 6.  Membrane perforation rate in lateral maxillary sinus floor augmentation using conventional rotating instruments and piezoelectric device-a meta-analysis.

Authors:  Corinne Jordi; Khaled Mukaddam; Jörg Thomas Lambrecht; Sebastian Kühl
Journal:  Int J Implant Dent       Date:  2018-01-29

Review 7.  Outcomes of implants placed after osteotome sinus floor elevation without bone grafts: a systematic review and meta-analysis of single-arm studies.

Authors:  Mingfu Ye; Wenjun Liu; Shaolong Cheng; Lihui Yan
Journal:  Int J Implant Dent       Date:  2021-08-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.