Literature DB >> 2315472

Rapid acquisition spin-echo (RASE) MR imaging: a new technique for reduction of artifacts and acquisition time.

S A Mirowitz1, J K Lee, J J Brown, S S Eilenberg, J P Heiken, W H Perman.   

Abstract

The rapid acquisition spin-echo (RASE) technique combines a short repetition time, a short echo time, and a single excitation pulse sequence with half-Fourier data sampling. This allows for acquisition of 11 strongly T1-weighted sections during a single 23-second breath-holding period. Measurements obtained from volunteers and with phantoms reveal that RASE images have a lower signal-to-noise ratio and contrast-to-noise ratio than do conventional multiacquisition spin-echo (SE) images due to reduced data acquisition. However, liver-spleen contrast and spatial resolution are not affected. Moreover, contrast-to-artifact (C/A) measurements are 77% greater with RASE. When normalized for imaging time, all parameters are significantly higher with RASE, with a C/A per unit time that was 338% higher. Randomized, blinded review of RASE and SE sequences from 20 patients was conducted to evaluate qualitative performance. Excellent to good performances for phase-encoding artifact reduction, edge sharpness, and overall image quality were recorded for 89%, 88%, and 86% of RASE examinations, respectively, versus 41%, 59%, and 47% of conventional SE examinations, respectively. All results were statistically significant with P less than .001. RASE is an easily implemented imaging technique that utilizes widely available existing technology. Its major benefits relate to significant reduction in imaging time, elimination of respiratory artifacts, and the potential for performing dynamic contrast material-enhanced screening examinations.

Entities:  

Mesh:

Year:  1990        PMID: 2315472     DOI: 10.1148/radiology.175.1.2315472

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Fast spin-echo imaging of the abdomen during breath-holding: an alternative to RASE and other fast imaging techniques.

Authors:  R C Nelson; J L Chezmar
Journal:  Gastrointest Radiol       Date:  1992

2.  Breathhold imaging of the upper abdomen using a circular polarized-array coil: comparison with standard body coil imaging.

Authors:  J Gauger; N G Holzknecht; C A Lackerbauer; H Sittek; K E Fiedler; R Petsch; M Reiser
Journal:  MAGMA       Date:  1996-06       Impact factor: 2.310

3.  Breath-hold MR imaging of focal liver lesions: comparison of fast and ultrasound techniques.

Authors:  J Gaa; H Fischer; G Laub; M Georgi
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

4.  Liver lesion detection: comparison between excitation-spoiling fat suppression and regular spin-echo at 1.5T.

Authors:  R C Semelka; H Hricak; K G Bis; W C Werthmuller; C B Higgins
Journal:  Abdom Imaging       Date:  1993

5.  HASTE sequence with parallel acquisition and T2 decay compensation: application to carotid artery imaging.

Authors:  Ling Zhang; Eugene G Kholmovski; Junyu Guo; Seong-Eun Kim Choi; Glen R Morrell; Dennis L Parker
Journal:  Magn Reson Imaging       Date:  2008-07-22       Impact factor: 2.546

6.  Post-processing sets of tilted CT volumes as a method for metal artifact reduction.

Authors:  Hendrik Ballhausen; Michael Reiner; Ute Ganswindt; Claus Belka; Matthias Söhn
Journal:  Radiat Oncol       Date:  2014-05-15       Impact factor: 3.481

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.