Literature DB >> 23154076

4π non-coplanar liver SBRT: a novel delivery technique.

Peng Dong1, Percy Lee, Dan Ruan, Troy Long, Edwin Romeijn, Yingli Yang, Daniel Low, Patrick Kupelian, Ke Sheng.   

Abstract

PURPOSE: To improve the quality of liver stereotactic body radiation therapy (SBRT) treatments, a novel 4π framework was developed with accompanying algorithms to optimize non-coplanar beam orientations and fluences. The dose optimization is performed on a patient-specific deliverable beam geometry solution space, parameterized with patient and linear accelerator gantry orientations. METHODS AND MATERIALS: Beams causing collision between the gantry and the couch or patient were eliminated by simulating all beam orientations using a precise computer assisted design model of the linear accelerator and a human subject. Integrated beam orientation and fluence map optimizations were performed on remaining beams using a greedy column generation method. Testing of the new method was performed on 10 liver SBRT cases previously treated with 50 to 60 Gy in 5 fractions using volumetric modulated arc therapy (VMAT). For each patient, both 14 and 22 non-coplanar fields were selected and optimized to meet the objective of ≥95% of the planning target volume (PTV) covered by 100% of the prescription dose. Doses to organs at risk, normal liver volumes receiving <15 Gy, integral dose, and 50% dose spillage volumes were compared against the delivered clinical VMAT plans.
RESULTS: Compared with the VMAT plans, the 4π plans yielded reduced 50% dose spillage volume and integral dose by 22% (range 10%-40%) and 19% (range 13%-26%), respectively. The mean normal liver volume receiving <15 Gy was increased by 51 cc (range 21-107 cc) with a 31% reduction of the mean normal liver dose. Mean doses to the left kidney and right kidney and maximum doses to the stomach and spinal cord were on average reduced by 70%, 51%, 67%, and 64% (P≤.05).
CONCLUSIONS: This novel 4π non-coplanar radiation delivery technique significantly improved dose gradient, reduced high dose spillage, and improved organ at risk sparing compared with state of the art VMAT plans.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23154076     DOI: 10.1016/j.ijrobp.2012.09.028

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  47 in total

1.  A novel software and conceptual design of the hardware platform for intensity modulated radiation therapy.

Authors:  Dan Nguyen; Dan Ruan; Daniel O'Connor; Kaley Woods; Daniel A Low; Salime Boucher; Ke Sheng
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  MRI morphologic alterations after liver SBRT : Direct dose correlation with intermodal matching.

Authors:  Judit Boda-Heggemann; Ulrike Attenberger; Johannes Budjan; Anika Jahnke; Lennart Jahnke; Lena Vogel; Anna O Simeonova-Chergou; Carsten Herskind; Frederik Wenz; Frank Lohr
Journal:  Strahlenther Onkol       Date:  2016-07-08       Impact factor: 3.621

3.  New concept on an integrated interior magnetic resonance imaging and medical linear accelerator system for radiation therapy.

Authors:  Xun Jia; Zhen Tian; Yan Xi; Steve B Jiang; Ge Wang
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-02

4.  Many-isocenter optimization for robotic radiotherapy.

Authors:  Qihui Lyu; Ryan Neph; Victoria Y Yu; Dan Ruan; Salime Boucher; Ke Sheng
Journal:  Phys Med Biol       Date:  2020-02-10       Impact factor: 3.609

5.  Analytical modeling and feasibility study of a multi-GPU cloud-based server (MGCS) framework for non-voxel-based dose calculations.

Authors:  J Neylon; Y Min; P Kupelian; D A Low; A Santhanam
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-08-25       Impact factor: 2.924

6.  Nonisocentric treatment strategy for breast radiation therapy: a proof of concept study.

Authors:  Ruijiang Li; Lei Xing; Kathleen C Horst; Karl Bush
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-15       Impact factor: 7.038

7.  4π plan optimization for cortical-sparing brain radiotherapy.

Authors:  Vyacheslav L Murzin; Kaley Woods; Vitali Moiseenko; Roshan Karunamuni; Kathryn R Tringale; Tyler M Seibert; Michael J Connor; Daniel R Simpson; Ke Sheng; Jona A Hattangadi-Gluth
Journal:  Radiother Oncol       Date:  2018-03-05       Impact factor: 6.280

8.  Parallel beamlet dose calculation via beamlet contexts in a distributed multi-GPU framework.

Authors:  Ryan Neph; Cheng Ouyang; John Neylon; Youming Yang; Ke Sheng
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

9.  Deterministic direct aperture optimization using multiphase piecewise constant segmentation.

Authors:  Dan Nguyen; Daniel O'Connor; Dan Ruan; Ke Sheng
Journal:  Med Phys       Date:  2017-09-22       Impact factor: 4.071

Review 10.  Advances in radiotherapy techniques and delivery for non-small cell lung cancer: benefits of intensity-modulated radiation therapy, proton therapy, and stereotactic body radiation therapy.

Authors:  Tejan P Diwanji; Pranshu Mohindra; Melissa Vyfhuis; James W Snider; Chaitanya Kalavagunta; Sina Mossahebi; Jen Yu; Steven Feigenberg; Shahed N Badiyan
Journal:  Transl Lung Cancer Res       Date:  2017-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.