The efficacy of noninvasive hemoglobin measurement by pulse CO-oximetry in neonates.

Young Hwa Jung1, Juyoung Lee, Han-Suk Kim, Seung Han Shin, Jin A Sohn, Ee-Kyung Kim, Jung-Hwan Choi.   

Abstract

OBJECTIVE: To evaluate clinical applicability of noninvasive hemoglobin (Hb) measurement with a pulse CO-oximeter in neonates.
DESIGN: Prospective comparison study.
SETTING: Neonatal ICU. PATIENTS: Fifty-six preterm and term infants with median age = 20 days (range = 1-98 days) and median weight = 1,440 g (range = 530-4,230 g).
INTERVENTIONS: Hb measurements by Pulse CO-Oximetry (Masimo Radical-7) were recorded immediately prior to venous samplings.
MEASUREMENTS AND MAIN RESULTS: The collected data were compared with the corresponding venous Hb level obtained in laboratory testing, and a total of 137 data pairs were analyzed. Noninvasive Hb values measured with a pulse CO-oximeter were significantly correlated with the venous Hb levels (correlation coefficient, r = 0.758; p < 0.001). Hb values measured with a pulse CO-oximeter were higher than those measured with a laboratory hematology analyzer (13.3 ± 2.6g/dL vs. 12.5 ± 3.1g/dL). In terms of the agreement between the laboratory analyzer and the pulse CO-oximeter, 94.8% of the measurements fell within two standard deviations of the mean difference.
CONCLUSION: Noninvasive Hb measurements with Pulse CO-Oximetry provide clinically acceptable accuracy, and they were significantly correlated with laboratory Hb measurement in neonates. In terms of the clinical applicability, noninvasive Hb monitoring with a pulse CO-oximeter could be useful in the early detection of Hb changes in neonates.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23132397     DOI: 10.1097/PCC.0b013e318260117d

Source DB:  PubMed          Journal:  Pediatr Crit Care Med        ISSN: 1529-7535            Impact factor:   3.624


  7 in total

1.  Comparison of the accuracy of noninvasive hemoglobin monitoring for preoperative evaluation between adult and pediatric patients: a retrospective study.

Authors:  Yong-Hee Park; Seho Lim; Hyun Kang; Hwa-Yong Shin; Chong Wha Baek; Young Cheol Woo
Journal:  J Clin Monit Comput       Date:  2018-01-04       Impact factor: 2.502

2.  Noninvasively Measured Hemoglobin Concentration Reflects Arterial Hemoglobin Concentration Before but Not After Cardiopulmonary Bypass in Patients Undergoing Coronary Artery or Valve Surgery.

Authors:  Matthias L Riess; Paul S Pagel
Journal:  J Cardiothorac Vasc Anesth       Date:  2016-03-24       Impact factor: 2.628

3.  Validation of noninvasive hemoglobin measurement by pulse co-oximeter in newborn infants.

Authors:  C Nicholas; R George; S Sardesai; M Durand; R Ramanathan; R Cayabyab
Journal:  J Perinatol       Date:  2015-03-05       Impact factor: 2.521

4.  Continuous hemoglobin measurement during frontal advancement operations can improve patient outcomes.

Authors:  Ayten Saracoglu; Ruslan Abdullayev; Mustafa Sakar; Bulent Sacak; Feyza Girgin Incekoy; Zuhal Aykac
Journal:  J Clin Monit Comput       Date:  2022-03-07       Impact factor: 2.502

5.  Minimizing blood loss and the need for transfusions in very premature infants.

Authors:  Brigitte Lemyre; Megan Sample; Thierry Lacaze-Masmonteil
Journal:  Paediatr Child Health       Date:  2015 Nov-Dec       Impact factor: 2.253

6.  Evaluation of a Noninvasive Hemoglobin Measurement Device to Screen for Anemia in Infancy.

Authors:  Daniel P Hsu; Alicia J French; Samuel L Madson; John M Palmer; Vinod Gidvani-Diaz
Journal:  Matern Child Health J       Date:  2016-04

7.  Validity of non-invasive point-of-care hemoglobin estimation in healthy and sick children-a method comparison study.

Authors:  Aditya Bhat; Amit Upadhyay; Vijay Jaiswal; Deepak Chawla; Dharamveer Singh; Mithilesh Kumar; C P Yadav
Journal:  Eur J Pediatr       Date:  2015-08-19       Impact factor: 3.183