Literature DB >> 23122945

Serial analysis of lumen geometry and hemodynamics in human arteriovenous fistula for hemodialysis using magnetic resonance imaging and computational fluid dynamics.

Yong He1, Christi M Terry, Cuong Nguyen, Scott A Berceli, Yan-Ting E Shiu, Alfred K Cheung.   

Abstract

The arteriovenous fistula (AVF) is the preferred form of vascular access for maintenance hemodialysis, but it often fails to mature to become clinically usable, likely due to aberrant hemodynamic forces. A robust pipeline for serial assessment of hemodynamic parameters and subsequent lumen cross-sectional area changes has been developed and applied to a data set from contrast-free MRI of a dialysis patient's AVF collected over a period of months after AVF creation surgery. Black-blood MRI yielded images of AVF lumen geometry, while cine phase-contrast MRI provided volumetric flow rates at the in-flow and out-flow locations. Lumen geometry and flow rates were used as inputs for computational fluid dynamics (CFD) modeling to provide serial wall shear stress (WSS), WSS gradient, and oscillatory shear index (OSI) profiles. The serial AVF lumen geometries were co-registered at 1mm intervals using respective lumen centerlines, with the anastomosis as an anatomical landmark. Lumen enlargement was limited at the vein region near the anastomosis and a downstream vein valve, potentially attributed to the physical inhibition of wall expansion at those sites. This work is the first serial and detail study of lumen and hemodynamic changes in human AVF using MRI and CFD. This novel protocol will be used for a multicenter prospective study to identify critical hemodynamic factors that contribute to AVF maturation failure.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23122945      PMCID: PMC4120947          DOI: 10.1016/j.jbiomech.2012.09.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  9 in total

1.  Comparison of the hemodynamics in 6mm and 4-7 mm hemodialysis grafts by means of CFD.

Authors:  Ilse Van Tricht; Dirk De Wachter; Jan Tordoir; Pascal Verdonck
Journal:  J Biomech       Date:  2006       Impact factor: 2.712

2.  Pulsatile flow in the human left coronary artery bifurcation: average conditions.

Authors:  X He; D N Ku
Journal:  J Biomech Eng       Date:  1996-02       Impact factor: 2.097

3.  Computational fluid dynamics simulation of a-v fistulas: from MRI and ultrasound scans to numeric evaluation of hemodynamics.

Authors:  Anders Koustrup Niemann; Samuel Thrysoe; Jens Vinge Nygaard; John Michael Hasenkam; Steffen Ellebaek Petersen
Journal:  J Vasc Access       Date:  2012 Jan-Mar       Impact factor: 2.283

4.  Computational fluid dynamics of a vascular access case for hemodialysis.

Authors:  B Ene-Iordache; L Mosconi; G Remuzzi; A Remuzzi
Journal:  J Biomech Eng       Date:  2001-06       Impact factor: 2.097

5.  Low-pressure environment and remodelling of the forearm vein in Brescia-Cimino haemodialysis access.

Authors:  Jean-Marc Corpataux; Erik Haesler; Paolo Silacci; Hans Beat Ris; Daniel Hayoz
Journal:  Nephrol Dial Transplant       Date:  2002-06       Impact factor: 5.992

6.  Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model.

Authors:  K Perktold; G Rappitsch
Journal:  J Biomech       Date:  1995-07       Impact factor: 2.712

7.  Effect of clopidogrel on early failure of arteriovenous fistulas for hemodialysis: a randomized controlled trial.

Authors:  Laura M Dember; Gerald J Beck; Michael Allon; James A Delmez; Bradley S Dixon; Arthur Greenberg; Jonathan Himmelfarb; Miguel A Vazquez; Jennifer J Gassman; Tom Greene; Milena K Radeva; Gregory L Braden; T Alp Ikizler; Michael V Rocco; Ingemar J Davidson; James S Kaufman; Catherine M Meyers; John W Kusek; Harold I Feldman
Journal:  JAMA       Date:  2008-05-14       Impact factor: 56.272

8.  Longitudinal assessment of hyperplasia using magnetic resonance imaging without contrast in a porcine arteriovenous graft model.

Authors:  Christi M Terry; Seong-Eun Kim; Li Li; K Craig Goodrich; J Rock Hadley; Donald K Blumenthal; Dennis L Parker; Alfred K Cheung
Journal:  Acad Radiol       Date:  2009-01       Impact factor: 3.173

9.  The natural history of autologous fistulas as first-time dialysis access in the KDOQI era.

Authors:  Andre Biuckians; Eric C Scott; George H Meier; Jean M Panneton; Marc H Glickman
Journal:  J Vasc Surg       Date:  2008-02       Impact factor: 4.268

  9 in total
  21 in total

Review 1.  Novel paradigms for dialysis vascular access: upstream hemodynamics and vascular remodeling in dialysis access stenosis.

Authors:  Andrea Remuzzi; Bogdan Ene-Iordache
Journal:  Clin J Am Soc Nephrol       Date:  2013-08-29       Impact factor: 8.237

Review 2.  New Insights into Dialysis Vascular Access: Molecular Targets in Arteriovenous Fistula and Arteriovenous Graft Failure and Their Potential to Improve Vascular Access Outcomes.

Authors:  Timmy Lee; Sanjay Misra
Journal:  Clin J Am Soc Nephrol       Date:  2016-07-11       Impact factor: 8.237

3.  Restoration of wall shear stress in the cephalic vein during extreme hemodynamics.

Authors:  M E Boghosian; M S Hammes; K W Cassel; S M J Akherat; F Coe
Journal:  J Med Eng Technol       Date:  2019-04-03

4.  Non-contrast MRI methods as a tool for the pre-operative assessment and surveillance of the arterio-venous fistula for haemodialysis.

Authors:  Conor J MacDonald; Stephen Gandy; Eilidh C M Avison; Shona Matthew; Rose Ross; John G Houston
Journal:  MAGMA       Date:  2018-08-21       Impact factor: 2.310

Review 5.  Arteriovenous conduits for hemodialysis: how to better modulate the pathophysiological vascular response to optimize vascular access durability.

Authors:  Yan-Ting Shiu; Joris I Rotmans; Wouter Jan Geelhoed; Daniel B Pike; Timmy Lee
Journal:  Am J Physiol Renal Physiol       Date:  2019-02-20

6.  The correlation between computed tomography and duplex evaluation of autogenous vein bypass grafts and their relationship to failure.

Authors:  Jonathan Rehfuss; Salvatore Scali; Yong He; Bradley Schmit; Kenneth Desart; Peter Nelson; Scott Berceli
Journal:  J Vasc Surg       Date:  2015-09-10       Impact factor: 4.268

7.  Comparison of hemodialysis arteriovenous fistula blood flow rates measured by Doppler ultrasound and phase-contrast magnetic resonance imaging.

Authors:  Yong He; Yan-Ting Shiu; Daniel B Pike; Prabir Roy-Chaudhury; Alfred K Cheung; Scott A Berceli
Journal:  J Vasc Surg       Date:  2018-05-18       Impact factor: 4.268

8.  Hemodynamic Shear Stress and Endothelial Dysfunction in Hemodialysis Access.

Authors:  Michelle K Fitts; Daniel B Pike; Kasey Anderson; Yan-Ting Shiu
Journal:  Open Urol Nephrol J       Date:  2014

9.  Hemodynamics in the cephalic arch of a brachiocephalic fistula.

Authors:  M Boghosian; K Cassel; M Hammes; B Funaki; S Kim; X Qian; X Wang; P Dhar; J Hines
Journal:  Med Eng Phys       Date:  2014-03-30       Impact factor: 2.242

10.  Analyses of hemodialysis arteriovenous fistula geometric configuration and its associations with maturation and reintervention.

Authors:  Yong He; Hannah Northrup; Prabir Roy-Chaudhury; Alfred K Cheung; Scott A Berceli; Yan-Ting Shiu
Journal:  J Vasc Surg       Date:  2020-10-20       Impact factor: 4.268

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.