Literature DB >> 23118373

The Hip Society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty.

A V Lombardi1, R L Barrack, K R Berend, J M Cuckler, J J Jacobs, M A Mont, T P Schmalzried.   

Abstract

Since 1996 more than one million metal-on-metal articulations have been implanted worldwide. Adverse reactions to metal debris are escalating. Here we present an algorithmic approach to patient management. The general approach to all arthroplasty patients returning for follow-up begins with a detailed history, querying for pain, discomfort or compromise of function. Symptomatic patients should be evaluated for intra-articular and extra-articular causes of pain. In large head MoM arthroplasty, aseptic loosening may be the source of pain and is frequently difficult to diagnose. Sepsis should be ruled out as a source of pain. Plain radiographs are evaluated to rule out loosening and osteolysis, and assess component position. Laboratory evaluation commences with erythrocyte sedimentation rate and C-reactive protein, which may be elevated. Serum metal ions should be assessed by an approved facility. Aspiration, with manual cell count and culture/sensitivity should be performed, with cloudy to creamy fluid with predominance of monocytes often indicative of failure. Imaging should include ultrasound or metal artifact reduction sequence MRI, specifically evaluating for fluid collections and/or masses about the hip. If adverse reaction to metal debris is suspected then revision to metal or ceramic-on-polyethylene is indicated and can be successful. Delay may be associated with extensive soft-tissue damage and hence poor clinical outcome.

Entities:  

Mesh:

Year:  2012        PMID: 23118373     DOI: 10.1302/0301-620X.94B11.30680

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  43 in total

1.  Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor.

Authors:  Adolph V Lombardi; Keith R Berend; Michael J Morris; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2014-11-04       Impact factor: 4.176

Review 2.  Biological response to prosthetic debris.

Authors:  Diana Bitar; Javad Parvizi
Journal:  World J Orthop       Date:  2015-03-18

3.  CORR Insights®: Revisions of Modular Metal-on-metal THA Have a High Risk of Early Complications.

Authors:  Peter F Sharkey
Journal:  Clin Orthop Relat Res       Date:  2019-02       Impact factor: 4.176

4.  [Cement-free and cemented Excia hip shaft prosthesis: comparison of intermediate term results].

Authors:  C Urschel; M Döring; W Strecker
Journal:  Orthopade       Date:  2014-09       Impact factor: 1.087

Review 5.  Revision total hip arthroplasty for metal-on-metal failure.

Authors:  Justin S Chang; Fares S Haddad
Journal:  J Clin Orthop Trauma       Date:  2019-10-04

6.  CORR Insights®: Frank Stinchfield Award: Identification of the At-risk Genotype for Development of Pseudotumors Around Metal-on-metal THAs.

Authors:  Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

7.  Particulate and ion forms of cobalt-chromium challenged preosteoblasts promote osteoclastogenesis and osteolysis in a murine model of prosthesis failure.

Authors:  Shuye Yang; Kai Zhang; Jianhao Jiang; Bonface James; Shang-You Yang
Journal:  J Biomed Mater Res A       Date:  2018-10-25       Impact factor: 4.396

8.  Adverse Reactions to Metal on Metal Are Not Exclusive to Large Heads in Total Hip Arthroplasty.

Authors:  Adolph V Lombardi; Keith R Berend; Joanne B Adams; Keri L Satterwhite
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

9.  601 metal-on-metal total hip replacements with 36 mm heads a 5 minimum year follow up: Levels of ARMD remain low despite a comprehensive screening program.

Authors:  Amit Atrey; Alister Hart; Nasir Hussain; Jonathon Waite; Andrew J Shepherd; Steve Young
Journal:  J Orthop       Date:  2016-10-31

10.  The utility of repeat ultrasound imaging in the follow-up of metal-on-metal hip arthroplasty patients.

Authors:  G S Matharu; S Janardhan; L Brash; P B Pynsent; D J Dunlop; S L J James
Journal:  Ann R Coll Surg Engl       Date:  2016-01-07       Impact factor: 1.891