Literature DB >> 30358096

Particulate and ion forms of cobalt-chromium challenged preosteoblasts promote osteoclastogenesis and osteolysis in a murine model of prosthesis failure.

Shuye Yang1,2, Kai Zhang2, Jianhao Jiang2, Bonface James3, Shang-You Yang1,3.   

Abstract

This study investigated the interactive behavior of the particulate and ion forms of cobalt-chromium (Co-Cr) alloy challenged preosteoblasts during the process of prosthetic implant loosening. Preosteoblasts were challenged with Co-Cr particles or Co(II) ions for 72 h, followed by the proliferation and PCR assays. For in vivo test, a titanium pin was implanted into proximal tibia of SCID mice to mimic knee replacement. Co-Cr particles or Co(II) ion challenged preosteoblasts (5 × 105 ) were intra-articularly injected into the implanted knee. The animals were sacrificed 5 weeks post-op, and the prosthetic knees were harvested for biomechanical pin-pullout testing, histological evaluations, and microCT assessment. In vitro study suggested that Co-Cr particles and Co(II) ions significantly suppressed the proliferation of preosteoblasts in a dose-dependent manner. RT-PCR data on the challenged cells indicated overexpression of receptor activator of nuclear factor kappa-B ligand (RANKL) and inhibited osteoprotegerin (OPG) gene expression. Introduction of the differently challenged preosteoblasts to the pin-implant mouse model resulted in reduced implant interfacial shear strength, thicker peri-implant soft-tissue formation, more TRAP+ cells, lower bone mineral density, and bone volume fraction. In conclusion, both Co-Cr particles and Co(II) ions interfered with the growth, maturation, and functions of preosteoblasts, and provides evidence that the metal ions as well play an important role in effecting preosteoblasts in the pathogenesis of aseptic loosening.
© 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 187-194, 2019. © 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  aseptic loosening; metal ion; osteoclast; preosteoblast; wear debris

Mesh:

Substances:

Year:  2018        PMID: 30358096      PMCID: PMC6366336          DOI: 10.1002/jbm.a.36553

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  35 in total

Review 1.  Biological reactions to wear debris in total joint replacement.

Authors:  E Ingham; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

Review 2.  Particles and periimplant bone resorption.

Authors:  Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2002-12       Impact factor: 4.176

3.  Orthopedic implant cobalt-alloy particles produce greater toxicity and inflammatory cytokines than titanium alloy and zirconium alloy-based particles in vitro, in human osteoblasts, fibroblasts, and macrophages.

Authors:  Ali Dalal; Vivek Pawar; Kyron McAllister; Carolyn Weaver; Nadim J Hallab
Journal:  J Biomed Mater Res A       Date:  2012-05-21       Impact factor: 4.396

4.  [Effect of metal ions Co2+ and Cr3+ on osteoblast apoptosis, cell cycle distribution, and secretion of alkaline phosphatase].

Authors:  Min Dai; Tonghua Zhou; Hao Xiong; Wennan Zou; Ping Zhan; Wenfeng Fu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2011-01

5.  Polymethylmethacrylate particles impair osteoprogenitor viability and expression of osteogenic transcription factors Runx2, osterix, and Dlx5.

Authors:  Richard Chiu; Kierann E Smith; Gene K Ma; Ting Ma; R Lane Smith; Stuart B Goodman
Journal:  J Orthop Res       Date:  2010-05       Impact factor: 3.494

6.  Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty.

Authors:  M T Clarke; P T H Lee; A Arora; R N Villar
Journal:  J Bone Joint Surg Br       Date:  2003-08

7.  [Allergy diagnostics in implant intolerance].

Authors:  P Thomas; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

8.  Effects of Ti, PMMA, UHMWPE, and Co-Cr wear particles on differentiation and functions of bone marrow stromal cells.

Authors:  Yunpeng Jiang; Tanghong Jia; Weiming Gong; Paul H Wooley; Shang-You Yang
Journal:  J Biomed Mater Res A       Date:  2013-03-05       Impact factor: 4.396

Review 9.  The Hip Society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty.

Authors:  A V Lombardi; R L Barrack; K R Berend; J M Cuckler; J J Jacobs; M A Mont; T P Schmalzried
Journal:  J Bone Joint Surg Br       Date:  2012-11

10.  Metal ion levels and functional results after either resurfacing hip arthroplasty or conventional metal-on-metal hip arthroplasty.

Authors:  José M H Smolders; Annemiek Hol; Willard J Rijnberg; Job L C van Susante
Journal:  Acta Orthop       Date:  2011-10       Impact factor: 3.717

View more
  1 in total

1.  The Mechanism of Metallosis After Total Hip Arthroplasty.

Authors:  Chinedu C Ude; Caldon J Esdaille; Kenneth S Ogueri; Kan Ho-Man; Samuel J Laurencin; Lakshmi S Nair; Cato T Laurencin
Journal:  Regen Eng Transl Med       Date:  2021-07-29
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.