Literature DB >> 23115417

A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures.

Karim Ghazikhanlou Sani1, Mahmoodreza Jafari, Nima Rostampoor.   

Abstract

The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were taken from other views (predominantly oblique views), making a total number of 128 radiographs. Paired radiographs, taken from the same areas, were compared by two radiologists in terms of image visual sharpness, presence of bony fractures, and soft tissue injuries. The surface dose received by patients in the two systems was also compared. The radiographs taken by mammography film-screen had a statistically better visual sharpness compared to those taken by the standard film-screen system. However, there was no statistically significant difference between the diagnostic accuracy of the two systems. Mammography film-screen was able to detect only one out of 57 lesions, whereas standard film-screen system did not detec any lesion. The surface dose received by patients in mammography film-screen was higher than that in standard film-screen system. The findings of the present study suggest that mammography film-screen may be recommended as a diagnostic tool for the detection of small fractures of tinny parts of body such as fingers, hand or foot. They also suggest that mammography film-screen has no advantage over standard film-screen for radiography of thick body parts such as neck and knee.

Entities:  

Keywords:  Bone fracture; X-Ray screen system; diagnostic techniques; mammography; surface dose

Year:  2011        PMID: 23115417      PMCID: PMC3470282     

Source DB:  PubMed          Journal:  Iran J Med Sci        ISSN: 0253-0716


  10 in total

1.  An in vitro study comparing two different film-screen combinations in the detection of impacted fish bones.

Authors:  B J Abdullah; H Kaur; K H Ng
Journal:  Br J Radiol       Date:  1998-09       Impact factor: 3.039

2.  Diagnostic errors in an accident and emergency department.

Authors:  H R Guly
Journal:  Emerg Med J       Date:  2001-07       Impact factor: 2.740

3.  Comparison of full-field digital mammography and film-screen mammography: image quality and lesion detection.

Authors:  A Fischmann; K C Siegmann; A Wersebe; C D Claussen; M Müller-Schimpfle
Journal:  Br J Radiol       Date:  2005-04       Impact factor: 3.039

4.  Evaluation of the diagnostic value of a computed radiography system by comparison of digital hard copy images with screen-film mammography: results of a prospective clinical trial.

Authors:  C Van Ongeval; H Bosmans; A Van Steen; K Joossens; V Celis; M Van Goethem; I Verslegers; K Nijs; F Rogge; G Marchal
Journal:  Eur Radiol       Date:  2006-03-02       Impact factor: 5.315

Review 5.  A review of methods of clinical image quality evaluation in mammography.

Authors:  Yanpeng Li; Ann Poulos; Donald McLean; Mary Rickard
Journal:  Eur J Radiol       Date:  2009-05-30       Impact factor: 3.528

6.  Evaluation of the entrance surface air kerma in mammographic examinations in Rio de Janeiro, Brazil.

Authors:  L C G Oliveira; T K Dias; R T Lopes; S Kodlulovich
Journal:  Radiat Prot Dosimetry       Date:  2009-03-14       Impact factor: 0.972

7.  AAPM tutorial. Mammography as a radiographic system.

Authors:  L B Hubbard
Journal:  Radiographics       Date:  1990-01       Impact factor: 5.333

8.  Image quality and dose in mammography in 17 countries in Africa, Asia and Eastern Europe: results from IAEA projects.

Authors:  Olivera Ciraj-Bjelac; Simona Avramova-Cholakova; Adnan Beganovic; Sotirios Economides; Dario Faj; Vesna Gershan; Edward Grupetta; M H Kharita; Milomir Milakovic; Constantin Milu; Wilbroad E Muhogora; Pirunthavany Muthuvelu; Samuel Oola; Saeid Setayeshi; Cyril Schandorf; Ion Ursulean; Ivan R Videnovic; Areesha Zaman; Julius Ziliukas; Madan M Rehani
Journal:  Eur J Radiol       Date:  2011-06-12       Impact factor: 3.528

9.  Optimization of dose and image quality for computed radiography and digital radiography.

Authors:  John E Aldrich; Emerenciana Duran; Pat Dunlop; John R Mayo
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

10.  Improved fracture detection using the mammographic film-screen combination.

Authors:  Y Faridah; Bjj Abdullah; Kh Ng
Journal:  Biomed Imaging Interv J       Date:  2005-07-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.