Literature DB >> 23112677

A fast and sensitive quantitative lateral flow immunoassay for Cry1Ab based on a novel signal amplification conjugate.

Chunxiang Chen1, Jian Wu.   

Abstract

A novel lateral flow immunoassay (LFIA) signal amplification strategy for the detection of Cry1Ab based on amplification via a polylysine (PL) chain and biotin-streptavidin system (BSAS) is described. In this system, multiple fluorescence dyes (FL) were directly coated on the surface of PL and conjugated with antibody via the BSAS for construction of novel signal amplification (FLPL-BSAS-mAb1) conjugates, in which FL, PL and BSAS were employed to improve the sensitivity of LFIA. Compared with conventional LFIA, the sensitivity of FLPL-BSAS-mAb1-based LFIA was increased by approximately 100-fold. Quantified linearity was achieved in the value range of 0-1,000 pg/mL. The limit of detection (LOD) was reached 10 pg/mL after optimization of reaction conditions. To our knowledge, this represents one of the most sensitive LFIA for Cry1Ab yet reported. Furthermore, the detection time for this method was about 10 min. Therefore, it should be an attractive alternative compared to conventional immunoassays in routine control for Cry1Ab.

Entities:  

Keywords:  cry1Ab; fluorescence dye; lateral flow biosensor; polylysine

Mesh:

Substances:

Year:  2012        PMID: 23112677      PMCID: PMC3478804          DOI: 10.3390/s120911684

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


Introduction

Genetically modified organisms (GMOs) have been mainly developed for mass production of agricultural plants. The Cry toxins are insecticidal proteins, which are considered to be harmless and non-toxic to human being and animals. However, there are still safety concerns among consumers about the side effects GMOs might cause on ecosystems [1]. For the detection of Cry1Ab, the most commonly used formats are enzyme-linked immunosorbent assay (ELISA) [1-4] and lateral flow immunoassay (LFIA) [5], while various innovative analytical techniques have also been developed for quantitative or qualitative detection of Cry1Ab protein [6-14]. However, the main drawback of ELISA is the relatively long assay time required, large-scale instruments and professional operating techniques. Conventional LFIA often suffers from poor quantitative discrimination and low analytical sensitivity. Therefore, it is of crucial importance to establish a rapid testing methodology for monitoring Cry toxins. In the past decades, several methods with different materials used as labels have been tested to increase the sensitivity for immunoassay, including fluorescence dye [15-17], liposomes [18-22], quantum dots (QDs) [23-27], polymers (dextran and polylysine chains) [28-31] and particles such as enzyme-gold nanoparticles [32], silica nanoparticles [33-38], superparamagnetic nanoparticles [39-41], polystyrene microparticles [42,43] and fluorescent europium(III) nanoparticles [44]. To overcome the limitations of traditional LFIA, the nanoparticle-based LFIA for signal amplification have achieved notable progress and improved sensing performance in a variety of biosensor systems. However, the sensitivity of LFIA cannot meet all demands from a variety of detection problems in food and environment nowadays. Thus, new kinds of signal amplification systems need to be explored. Here, we present a novel signal amplification strategy in LFIA, which adopts three amplification steps: (a) biotin-streptavidin amplification; (b) polylysine amplification; (c) fluorescence dye signal amplification. The biotin-streptavidin system (BSAS) has been widely applied in immunohistochemistry and immunoassay for its high specificity and strong affinity [45,46]. Streptavidin (SA) contains four binding sites with an extraordinarily high affinity for biotin. In this paper, we explored the use of this novel signal amplification conjugate as label for direct electronic signal measurement in LFIA. This efficient way to increase the sensitivity was achieved by amplification of the signals, which were generated from the fluorescence dye-antibody conjugate with a high fluorescence dye-to-antibody ratio. When FLPL-BSAS-mAb1 conjugate is bound to one antigen, tens or hundreds of fluorescence dye molecules would bind to a single antigen, consequently leading to signal amplification. In this assay, the resulting conjugates achieved a detection limit 100-fold lower than that of the magnetic beads-based ELISA [13] and gold-based LFIA [5]. The influence of some important parameters such as the type of nitrocellulose (NC) membrane, the structure of FLPL-BSAS-mAb1 conjugates and detection time of the present method were investigated in detail. Furthermore, the analytical performance of FLPL-BSAS-mAb1-based LFIA was further evaluated and its precision was also discussed.

Materials and Methods

Reagents and Materials

A nitrocellulose (NC) membrane, absorbent pad, sample pad, conjugate pad, and backing cards were purchased from Millipore (Bendford, MA, USA). Purified Cry1Ab protein, rabbit polyclonal antibody against Cry1Ab (pAb2), mouse monoclonal antibody against Cry1Ab (mAb1) and Bt Cry1Ab/1Ac/1F ELISA Kit were obtained from Abraxis LLC (Warminster, PA, USA), while Atto 647N (λabsmax = 644 nm, λemmax = 669 nm), polylysine (30–70 KD), bovine serum albumin (BSA), N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride (EDC), N-hydroxysuccinimide (NHS), streptavidin (SA), biotin and dimethyl sulfoxide (DMSO) were from Sigma (St. Louis, MO, USA). Other Cry proteins (Cry1C, Cry2A, Cry3A) were from Agdia Inc. (ElKart, IN, USA). Goat anti-rabbit IgG (GAR, >95%), rabbit IgG (RIgG, >95%) were obtained from Longji (Hangzhou, China). Dialysis tubing (20 KD) was from Spectrum Labs (Rancho Dominguez, CA, USA). All other analytical purified reagents were purchased domestically without further treatment or purification.

Apparatus

An XYZ Biostrip Dispenser and CM 4000 Cutter were purchased from Bio-Dot (Irvine, CA, USA). A portable fluorescence strip reader ESE-Quant FLUO was purchased from Invitrogen (Carlsbad, CA, USA). The ultracentrifuge is from Heraeus Biofuge Stratos (Sollentum, Germany). The SepectraMax M5 multi-mode microplate reader was from Molecular Devices (Sunnyvale, CA, USA).

Preparation of FLPL-BSAS-mAb1 Conjugates

Preparation FLPL and RIgG-FL Conjugates

Briefly, biotin (2.44 mg) together with EDC (19.14 mg) and NHS (11.49 mg) were dissolved in 0.01 M phosphate buffer saline (PBS, pH 7.4, 0.1 mL) and stirred for 15 min at room temperature (RT). This solution was then added dropwise to polylysine (PL) solution (polylysine: 450 mg in 1 mL of 0.01 M PBS at pH 7.2) so the PL: biotin molar ratio was 1:1. The mixture was stirred at RT for 1 h and excessive unreacted biotin and ions in aqueous solution were removed by size exclusion (5 KD) column chromatography against PBS buffer (0.01 M, pH 7.4). Then the biotin-labeled PL was labeled with Atto 647N according to the Atto 647N protein labeling kit protocol from Sigma. Firstly, the solution of biotin-labeled PL was added with sodium bicarbonate buffer solution (pH 9.5), adjusted to pH 8.5–9.0 and transferred to Atto 647N (1 mg Atto 647N dissolved in 10 μL DMSO), incubated at room temperature under gentle shaking for 2 h, followed by being separated conjugates from free dye by a size-exclusion column. Finally, the Atto 647N labeled polylysine (FLPL conjugate) fraction was collected and stored at 4 °C. The rabbit polyclonal antibody-Atto 647N conjugate (RIgG-FL) was obtained and purified with the same process.

Preparation of Biotinylated-mAb1

Biotinylation of Mouse monoclonal antibody (mAb1) was performed as described in Section 2.3.1. The molar ratio of biotin to mAb1 was 2:1. After labeling, excessive unreacted biotin and ions in aqueous solution were removed by dialysis against PBS buffer (0.01 M, pH 7.4) for 2 days. Then, it was stored in −20 °C until use.

Preparation of FLPL-BSAS-mAb1 Conjugate

The biotinylated-mAb1, streptavidin and FLPL conjugate were mixed in a molar ratio equal to 1:1:3 or 1:2:6 (Table 1). The conjugating mechanism of FLPL-BSAS-mAb1 conjugates was shown in Figure 1. Finally, FLPL-BSAS-mAb1 conjugate and RIgG-FL (1:1, v/v) were dispersed in stock solution (1% BSA and 0.005% sodium azide in 0.01 M PBS pH 7.4), respectively, and kept at 4 °C until use.
Table 1.

Properties of FLPL-BSAS-mAb1 conjugate prepared with different conjugate types.

Type NoMolar ratioMix order a,bIntensity c(mV)

biotinylated-mAb1streptavidinFLPL conjugate
A113Method 110
B113Method 2137
C126Method 1298
D126Method 2285

Order 1: Method 1: streptavidin was added into the biotinylated-mAb1 solution prior to the addition of FLPL conjugate; Method 2: streptavidin was added into the FLPL conjugate solution prior to the addition of iotinylated-mAb1.

Reaction time of each mix step: 30 min.

The intensities of test line were obtained with a portable strip reader. Concentration of Cry1Ab: 1,000 pg/mL.

Figure 1.

Preparation process of FLPL-BSAS-mAb1 conjugate.

Preparation of Lateral Flow Immunoassay System

The main body of the test strip consisted of five parts, including plastic backing, sample pad, conjugate pad, absorbent pad and NC membrane (Figure 2). Every component of the strip should be given a pretreatment described as follows: the NC membrane was attached to a plastic backing layer for cutting and handling. The pAb2 and GAR were immobilized at test line (T line) and control line (C line), respectively. The glass fiber was cut into two sizes 0.5 cm × 0.4 cm and 2.2 cm × 0.4 cm for the conjugate pad and sample pad. Conjugate pad contained FLPL-BSAS-mAb1 conjugate and RIgG-FL diluted by 0.01 M PBS buffer (pH 7.4) containing BSA (0.5%, w/v) and sucrose (3%, w/v). Sample pad was pretreated with BSA (3%, w/v) and Tween-20 (0.5%, w/v). Absorbent pad was 2.2 cm × 0.4 cm in size, attached to the top side of the strip.
Figure 2.

Schematic diagrams of FLPL-BSAS-mAb1 based LFIA.

Lateral Flow Test Procedure

Prior to the immunoassay, varying concentration of Cry1Ab standard solutions ranging from 0 to 1,000 pg/mL, were prepared by dilution in PBS buffer. One hundred μL of sample was loaded onto the sample pad of the strip, the test cartridge was inserted into the portable fluorescence strip reader after 10 min. The intensities of fluorescence conjugates on the detection zone were scanned and converted to area values. All experiments were performed in triplicate, and the average of the triplicates was used for the analysis.

Optimization Sensitivity of LFIA

Optimization of FLPL-BSAS-mAb1 Conjugate

As described in Section 2.3.3, the biotinylated-mAb1, streptavidin and FLPL conjugate were mixed in different ratios and two different mixing orders were tested (see Table 1). In order to obtained higher signal amplification conjugate, different conjugate procedures were used in preparation.

Optimization of NC Membrane

Five kinds of NC membranes (Millipore HF090, Millipore HF135, Sartourius CN95, Sartourius CN 140 and Whatman AE99) from different manufacturers were tested, respectively, according to the procedure described in Section 2.5. In this investigation, C line was coated with 1 mg/mL GAR, and T line was coated with 1 mg/mL pAb2. PBS buffer (10 mM, pH 7.4) was used as negative sample. After chromatography for 10 min, signals at the T and C line were measured.

Optimization of Detection Time

Standard solution (1,000 pg/mL) was applied on the sample pad and allowed to migrate across the NC membrane. Signals of T line and C line were read every minute for 12 min.

Sample Preparation for Immunoassay Methods

Non-GM maize was purchased from a local market in Hangzhou, China, and verified with Bt Cry1Ab/1Ac/1F ELISA Kit. One hundred mg of the obtained non-GM maize flour was mixed with 1 mL of the extraction buffer (Tris-borate buffer, pH 7.5) and spiked with known amounts of Cry1Ab to obtain samples with different concentrations of 0, 5, 10, 30, 60, 125, 250, 500, 1,000 pg/mL [4]. Sample without Cry1Ab was used as a blank. Each mixture was shaken for 30 min and centrifuged at 8,000 g for 30 min to remove insoluble material. The liquid protein extract was used in the assay.

Results and Discussion

Principle of FLPL-BSAS-mAb1 Based LFIA

FLPL-BSAS-mAb1-based LFIA combined the unique optical properties of FL with a signal amplification system for ultrasensitive detection of Cry1Ab. The protocol of FLPL-BSAS-mAb1 conjugate preparation was illustrated in Figure 1 and set-up of the LFIA in Figure 2. Standard solution containing target Cry1Ab was added on the sample pad, migrated by capillary action and passed the NC membrane. Finally, the Cry1Ab were captured by the pAb2 on the T line, while FLPL-BSAS-mAb1 conjugate were captured by Cry1Ab. The FL intensity at the T line was proportional to the concentration of Cry1Ab protein and scanned by a portable fluorescence strip reader. The GAR was fixed at control line served as an internal control after the reaction with RIgG-FL. Figure 3(A) shows the relative fluorescence intensity (RFI) profile from the scanned test strip. The first peak and the second peak displayed RFI on T and C line, respectively, as plotted in the y-axis. The distance of strip was plotted in x-axis. The RFI of the C line was almost unchanged in different samples, indicating that the C line is functioning as a good internal standard.
Figure 3.

(A) Response for Cry1Ab concentration of 0, 5, 10, 30, 60, 125, 250, 500, and 1,000 pg/mL in buffer; (B) The calibration curve obtained from the area ration (AT/AC) against the concentration of Cry1Ab in buffer.

The use of polylysine with a big amount of primary amino was vital for signal amplification in LFIA, which in turn would influence the loading amount of Atto 647N on the conjugate. The biotinylated-mAb1 and FLPL conjugate self-assembled via the streptavidin–biotin system. We compared the analytical performances of four types of conjugates prepared through different conjugation procedures (Table 1). In the presence of Cry1Ab (1,000 pg/mL), there was a very weak response observed with Type 1 conjugate (T1) and the highest responses were achieved by Type 3 and Type 4 conjugates (T3 and T4). Figure 4 illustrates the sequential steps and structures of various conjugates prepared by chemical modification of mAb1. T3 and T4 had similar signal intensity and 2-fold higher than type 2 conjugate (T2), indicating they may have similar structures. In addition, T3 and T4 demonstrated a 60-fold higher intensity compared to T1. Therefore, we propose three kinds of structures for these conjugates. In these tests, the signal response of T1 accumulated on the bottom of the NC membrane, that may be caused by the steric hindrance effect of a polymer, as only a few tiny polymers could migrate across the NC membrane (Figure 4, panel A), so T1 might be structure 1. T2 might be structure 2, while T3 and T4 might be structure 3, because structure 3 potentially has 2-fold more FL molecules conjugated on mAb1 and would be expected to generate a 2-fold higher response compared to structure 2 (Figure 4, panels B, C and D, respectively). Thus, structure 3 was used to fix on conjugate pad for the following experiments. Furthermore, we have attempted to apply longer polylysine (70−150 KD) to construct higher bright conjugates, but the results indicated that conjugates with longer polylysine chains cannot for pass through the NC membrane, because they would clog in the membrane pores (data not shown).
Figure 4.

Chemical structures of various FLPL-BSAS-mAb1 conjugates.

Responses at the T lines on five NC membranes were compared in Figure 5. Responses of strips constructed with Sartorius CN 140 membrane were the highest, while the response of strips constructed from Whatman AE 99 membrane were the lowest in the presence of 1,000 pg/mL Cry1Ab. In detection of 0 ppt Cry1Ab, a little response could be observed on Millipore HF135, Sartourius CN95, Sartourius CN 140 and WhatmanAE99, because a few of the FLPL-BSAS-mAb1 conjugates would physically clog the small size of pores of these NC membranes, but almost no response could be observed on the Millipore HF 090 membrane in detection of 0 ppt Cry1Ab. With consideration both of the responses on 0 and 1,000 pg/mL, Millipore HF 090 was selected as the most suitable NC membrane for strip preparation in the following experiments.
Figure 5.

Responses at T lines on five different NC membranes (CN 95, HF 090, CN 140, HF 135, AE 99).

The time-intensity curves were obtained by measuring the signals of the T and C lines every minute for 12 min after standard solution addition. The time-intensity curves and time-signal ratio AT/AC curve at one concentration of 1,000 pg/mL are shown in Figure 6, respectively.
Figure 6.

Trend of signals on T line and C line with time at 1,000 pg/mL.

The T line and C line signals increased rapidly during the first 25 min, between 25 and 45 min, the signals increased slowly and entered a plateau (data not shown). The time-signal ratio AT/AC curves of the first 12 min have been observed, and indicated that AT/AC would vary in the first 9 min, then gradually plateau, indicating the signal intensity was relatively stable for analysis (reading) over 9−12 min. With consideration of signal intensity for low concentration sample and the shortest time for detection, the detection time was considered as 10 min.

Method Evaluation

Sensitivity

After optimizing the signal amplification system, a series of Cry1Ab samples were tested by the FLPL-BSAS-mAb1-based LFIA to obtain a standard curve. Quantitative detection data is illustrated in Figure 3(A). There was an obvious increase in signals at the T line with the increasing Cry1Ab concentration. A standard curve for Cry1Ab was plotted by the signal ratio AT/AC at different Cry1Ab concentrations (Figure 3(B)). It showed good linearity in the range between 0 and 1,000 pg/mL; the equation was: while the correlation coeffcients were calculated to be 0.9958. The coefficients of variation (CV) values were both lower than 10%. The cut off level for all detection systems was calculated by the following equation: A detection limit of 10 pg/mL was achieved, which was 100 times lower than that of the magnetic beads- based ELISA [13] and gold-based LFIA [5]. This suggested that the proposed method is highly sensitive, especially for detection of biomolecules at low levels.

Specificity

The cross-reactivity (CR) and specificity of FLPL-BSAS-mAb1 based LFIA for Cry1Ab was assessed with available different samples: Cry1C, Cry2A, Cry3A. It was checked with different dilutions of above proteins but there was no cross-reactivity with those three transgenic proteins, indicating that this assay can be used for unique quantification of Cry1Ab protein.

Accuracy Evaluation

As ingredients in food are more complicated than the PBS buffer, Cry1Ab recovery rates in flour matrix were calculated to evaluate the influence of matrix on detection of target cry1Ab. It was calculated using the formula: and expressed in percent. As shown in Table 2, the recoveries were ranged from 80.05% to 109.69% with CVs of 3.8–9.5% in signal-amplification-based LFIA.
Table 2.

Recovery and precision of FLPL-BSAS-mAb1 based LFIA spiked in flour sample (n = 5).

Spiked Concentration (pg/mL)Mean a (pg/mL)SDRecovery (%)CV (%)
5040.021.5280.053.8
200210.1813.03105.096.2
500480.9536.0696.197.5
800877.5283.36109.699.5

The mean and standard deviation values were calculated from five independent experiments.

Conclusions

In conclusion, in this paper, one signal-amplification-based LFIA for ultrasensitive detection of Cry1Ab has been developed with very high analytical sensitivity (10 pg/mL) and short turnaround time (10 min). The signal of FLPL-BSAS-mAb1 conjugate was enlarged by increasing the amount of fluorescence dye loading on antibody via a polylysine chain and biotin–streptavidin system. It was found that PL and BSAS played very important roles to improve the sensitivity of the assay. Furthermore, optimization of factors which may affect the detection sensitivity and method assessment were also described. This method was applicable in a flour matrix. Therefore, FLPL-BSAS-mAb1-based LFIA has great potential to improve detection sensitivity, making is a useful technique for more sensitive and quantitative immunoassays.
  34 in total

1.  Performance of fluorescent europium(III) nanoparticles and colloidal gold reporters in lateral flow bioaffinity assay.

Authors:  Etvi Juntunen; Tiina Myyryläinen; Teppo Salminen; Tero Soukka; Kim Pettersson
Journal:  Anal Biochem       Date:  2012-06-13       Impact factor: 3.365

2.  Development of an innovative immunoassay for CP4EPSPS and Cry1AB genetically modified protein detection and quantification.

Authors:  M Ermolli; A Prospero; B Balla; M Querci; A Mazzeo; G Van Den Eede
Journal:  Food Addit Contam       Date:  2006-09

3.  First application of a microsphere-based immunoassay to the detection of genetically modified organisms (GMOs): quantification of Cry1Ab protein in genetically modified maize.

Authors:  Anna Fantozzi; Monica Ermolli; Massimiliano Marini; Domenico Scotti; Branko Balla; Maddalena Querci; Stephen R H Langrell; Guy Van den Eede
Journal:  J Agric Food Chem       Date:  2007-02-21       Impact factor: 5.279

4.  Binding properties of a monoclonal antibody against the Cry1Ab from Bacillus Thuringensis for the development of a capillary electrophoresis competitive immunoassay.

Authors:  Cristina Giovannoli; Laura Anfossi; Claudio Baggiani; Gianfranco Giraudi
Journal:  Anal Bioanal Chem       Date:  2008-01-10       Impact factor: 4.142

5.  High sensitive detection of Cry1Ab protein using a quantum dot-based fluorescence-linked immunosorbent assay.

Authors:  Xiaolei Zhu; Lili Chen; Ping Shen; Junwei Jia; Dabing Zhang; Litao Yang
Journal:  J Agric Food Chem       Date:  2011-02-17       Impact factor: 5.279

6.  Quantitative analysis of a prostate-specific antigen in serum using fluorescence immunochromatography.

Authors:  Jisun Yoo; Young Mee Jung; Jong Hoon Hahn; Dongjin Pyo
Journal:  J Immunoassay Immunochem       Date:  2010

7.  Sensitive immunoassay of a biomarker tumor necrosis factor-alpha based on poly(guanine)-functionalized silica nanoparticle label.

Authors:  Jun Wang; Guodong Liu; Mark H Engelhard; Yuehe Lin
Journal:  Anal Chem       Date:  2006-10-01       Impact factor: 6.986

8.  A sensitive immunoassay based on direct hapten coated format and biotin-streptavidin system for the detection of chloramphenicol.

Authors:  Na Sai; Yiping Chen; Nan Liu; Guanggui Yu; Pu Su; Yi Feng; Zhijiang Zhou; Xiaoyu Liu; Huanying Zhou; Zhixian Gao; Bao An Ning
Journal:  Talanta       Date:  2010-06-23       Impact factor: 6.057

9.  Development and validation of a sensitive enzyme immunoassay for surveillance of Cry1Ab toxin in bovine blood plasma of cows fed Bt-maize (MON810).

Authors:  Vijay Paul; Kerstin Steinke; Heinrich H D Meyer
Journal:  Anal Chim Acta       Date:  2007-11-19       Impact factor: 6.558

10.  Determination of protein-protein interactions through aldehyde-dextran intermolecular cross-linking.

Authors:  Manuel Fuentes; Rosa L Segura; Olga Abian; Lorena Betancor; Aurelio Hidalgo; Cesar Mateo; Roberto Fernandez-Lafuente; Jose M Guisan
Journal:  Proteomics       Date:  2004-09       Impact factor: 3.984

View more
  8 in total

Review 1.  Suspension arrays based on nanoparticle-encoded microspheres for high-throughput multiplexed detection.

Authors:  Yuankui Leng; Kang Sun; Xiaoyuan Chen; Wanwan Li
Journal:  Chem Soc Rev       Date:  2015-05-29       Impact factor: 54.564

2.  Aptasensor based on fluorophore-quencher nano-pair and smartphone spectrum reader for on-site quantification of multi-pesticides.

Authors:  Nan Cheng; Yang Song; Qiangqiang Fu; Dan Du; Yunbo Luo; Yong Wang; Wentao Xu; Yuehe Lin
Journal:  Biosens Bioelectron       Date:  2018-06-02       Impact factor: 10.618

3.  Development of quantum dot-based fluorescence lateral flow immunoassay strip for rapid and quantitative detection of serum interleukin-6.

Authors:  Jinsong Tang; Lili Wu; Jingtao Lin; Erying Zhang; Yong Luo
Journal:  J Clin Lab Anal       Date:  2021-03-24       Impact factor: 2.352

4.  A Novel Impedimetric Microfluidic Analysis System for Transgenic Protein Cry1Ab Detection.

Authors:  Shunru Jin; Zunzhong Ye; Yixian Wang; Yibin Ying
Journal:  Sci Rep       Date:  2017-03-02       Impact factor: 4.379

5.  Paper strip-embedded graphene quantum dots: a screening device with a smartphone readout.

Authors:  Ruslan Álvarez-Diduk; Jahir Orozco; Arben Merkoçi
Journal:  Sci Rep       Date:  2017-04-20       Impact factor: 4.379

6.  PCB-Based Magnetometer as a Platform for Quantification of Lateral-Flow Assays.

Authors:  Mohammad Khodadadi; Long Chang; João R C Trabuco; Binh V Vu; Katerina Kourentzi; Richard C Willson; Dmitri Litvinov
Journal:  Sensors (Basel)       Date:  2019-12-10       Impact factor: 3.576

7.  Performance improvement of the one-dot lateral flow immunoassay for aflatoxin B1 by using a smartphone-based reading system.

Authors:  Sangdae Lee; Giyoung Kim; Jihea Moon
Journal:  Sensors (Basel)       Date:  2013-04-18       Impact factor: 3.576

8.  Fluorescent fullerene nanoparticle-based lateral flow immunochromatographic assay for rapid quantitative detection of C-reactive protein.

Authors:  Kyung Mi Park; Da Jung Chung; Mijin Choi; Taejoon Kang; Jinyoung Jeong
Journal:  Nano Converg       Date:  2019-11-01
  8 in total