Literature DB >> 15365670

Multi-analyte single-membrane biosensor for the serotype-specific detection of Dengue virus.

Natalya V Zaytseva1, Richard A Montagna, Eun Mi Lee, Antje J Baeumner.   

Abstract

A multi-analyte biosensor based on nucleic acid hybridization and liposome signal amplification was developed for the rapid serotype-specific detection of Dengue virus. After RNA amplification, detection of Dengue virus specific serotypes can be accomplished using a single analysis within 25 min. The multi-analyte biosensor is based on single-analyte assays (see Baeumner et al (2002) Anal Chem 74:1442-1448) developed earlier in which four analyses were required for specific serotype identification of Dengue virus samples. The multi-analyte biosensor employs generic and serotype-specific DNA probes, which hybridize with Dengue RNA that is amplified by the isothermal nucleic acid sequence based amplification (NASBA) reaction. The generic probe (reporter probe) is coupled to dye-entrapping liposomes and can hybridize to all four Dengue serotypes, while the serotype-specific probes (capture probes) are immobilized through biotin-streptavidin interaction on the surface of a polyethersulfone membrane strip in separate locations. A mixture of amplified Dengue virus RNA sequences and liposomes is applied to the membrane and allowed to migrate up along the test strip. After the liposome-target sequence complexes hybridize to the specific probes immobilized in the capture zones of the membrane strip, the Dengue serotype present in the sample can be determined. The amount of liposomes immobilized in the various capture zones directly correlates to the amount of viral RNA in the sample and can be quantified by a portable reflectometer. The specific arrangement of the capture zones and the use of unlabeled oligonucleotides (cold probes) enabled us to dramatically reduce the cross-reactivity of Dengue virus serotypes. Therefore, a single biosensor can be used to detect the exact Dengue serotype present in the sample. In addition, the biosensor can simultaneously detect two serotypes and so it is useful for the identification of possible concurrent infections found in clinical samples. The various biosensor components have been optimized with respect to specificity and sensitivity, and the system has been ultimately tested using blind coded samples. The biosensor demonstrated 92% reliability in Dengue serotype determination. Following isothermal amplification of the target sequences, the biosensor had a detection limit of 50 RNA molecules for serotype 2, 500 RNA molecules for serotypes 3 and 4, and 50,000 molecules for serotype 1. The multi-analyte biosensor is portable, inexpensive, and very easy to use and represents an alternative to current detection methods coupled with nucleic acid amplification reactions such as electrochemiluminescence, or those based on more expensive and time consuming methods such as ELISA or tissue culture.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15365670     DOI: 10.1007/s00216-004-2724-9

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  17 in total

Review 1.  Opportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19.

Authors:  Nikhil Bhalla; Yuwei Pan; Zhugen Yang; Amir Farokh Payam
Journal:  ACS Nano       Date:  2020-06-26       Impact factor: 15.881

Review 2.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

3.  Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection.

Authors:  Clarisse E Buensuceso; Brylee David B Tiu; Luke P Lee; Portia Mahal G Sabido; Guillermo M Nuesca; Eugene B Caldona; Florian R Del Mundo; Rigoberto C Advincula
Journal:  Anal Bioanal Chem       Date:  2021-11-08       Impact factor: 4.142

4.  Biopatterning for label-free detection.

Authors:  Julie M Goddard; Sudeep Mandal; Sam R Nugen; Antje J Baeumner; David Erickson
Journal:  Colloids Surf B Biointerfaces       Date:  2009-11-01       Impact factor: 5.268

5.  Enhanced on-chip SERS based biomolecular detection using electrokinetically active microwells.

Authors:  Yun Suk Huh; Aram J Chung; Bernardo Cordovez; David Erickson
Journal:  Lab Chip       Date:  2008-11-12       Impact factor: 6.799

Review 6.  Microfluidics-based lab-on-chip systems in DNA-based biosensing: an overview.

Authors:  Sabo Wada Dutse; Nor Azah Yusof
Journal:  Sensors (Basel)       Date:  2011-05-27       Impact factor: 3.576

Review 7.  A Review of Membrane-Based Biosensors for Pathogen Detection.

Authors:  Remko van den Hurk; Stephane Evoy
Journal:  Sensors (Basel)       Date:  2015-06-15       Impact factor: 3.576

8.  Emerging technologies for the detection of rabies virus: challenges and hopes in the 21st century.

Authors:  Anthony R Fooks; Nicholas Johnson; Conrad M Freuling; Philip R Wakeley; Ashley C Banyard; Lorraine M McElhinney; Denise A Marston; Akbar Dastjerdi; Edward Wright; Robin A Weiss; Thomas Müller
Journal:  PLoS Negl Trop Dis       Date:  2009-09-29

9.  A fast and sensitive quantitative lateral flow immunoassay for Cry1Ab based on a novel signal amplification conjugate.

Authors:  Chunxiang Chen; Jian Wu
Journal:  Sensors (Basel)       Date:  2012-08-27       Impact factor: 3.576

10.  Lateral flow microarrays: a novel platform for rapid nucleic acid detection based on miniaturized lateral flow chromatography.

Authors:  Darren J Carter; R Bruce Cary
Journal:  Nucleic Acids Res       Date:  2007-05-03       Impact factor: 16.971

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.