Literature DB >> 20507134

Quantum dot-based immunochromatographic fluorescent biosensor for biomonitoring trichloropyridinol, a biomarker of exposure to chlorpyrifos.

Zhexiang Zou1, Dan Du, Jun Wang, Jordan N Smith, Charles Timchalk, Yaoqun Li, Yuehe Lin.   

Abstract

A novel and portable fluorescent sensor that integrates an immunochromatographic test strip assay (ITSA) with a quantum dot (QD) label and a test strip reader was described in this study for simple, rapid, and sensitive biomonitoring of an organophosphorus pesticide metabolite. The principle of this sensor is based on a competitive immunoreaction that was performed on an immunochromatographic test strip, where analytes compete with competitors (QD-conjugated analogs) to bind to antibodies on a test zone. Captured QDs serve as signal vehicles for fluorescent readout. In this work, 3,5,6-trichloropyridinol (TCP) is used as a model analyte to demonstrate the performance of the immunosensor. QD-TCP conjugates were synthesized and characterized with X-ray photoelectron spectroscopy (XPS) and fluorescence spectroscopy. Some parameters (e.g., the amount of QD-modified TCP and immunoreaction time) that govern sensitivity and reproducibility of ITSA were optimized. Under optimal conditions, the sensor has a wide dynamic range and is capable of detecting a minimum 1.0 ng/mL TCP standard analyte in 15 min. The sensor has been successfully applied for detection of TCP spiked in rat plasma with average recovery of 102.0%. Results demonstrate that this sensor provides a rapid, clinically accurate, and quantitative tool for TCP detection and shows great promise for in-field and point-of-care (POC) quantitative testing and screening for metabolite biomarkers, e.g., TCP, for humans exposed to pesticides.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20507134     DOI: 10.1021/ac100260m

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  21 in total

1.  A low-cost smartphone-based platform for highly sensitive point-of-care testing with persistent luminescent phosphors.

Authors:  Andrew S Paterson; Balakrishnan Raja; Vinay Mandadi; Blane Townsend; Miles Lee; Alex Buell; Binh Vu; Jakoah Brgoch; Richard C Willson
Journal:  Lab Chip       Date:  2017-03-14       Impact factor: 6.799

2.  Gold nanocage-based lateral flow immunoassay for immunoglobulin G.

Authors:  Yunhui Yang; Mehmet Ozsoz; Guodong Liu
Journal:  Mikrochim Acta       Date:  2017-03-31       Impact factor: 5.833

3.  Simultaneous detection of dual biomarkers from humans exposed to organophosphorus pesticides by combination of immunochromatographic test strip and ellman assay.

Authors:  Mingming Yang; Yuting Zhao; Limin Wang; Michael Paulsen; Christopher D Simpson; Fengquan Liu; Dan Du; Yuehe Lin
Journal:  Biosens Bioelectron       Date:  2017-12-21       Impact factor: 10.618

4.  Colloidal gold nanoparticle probe-based immunochromatographic assay for the rapid detection of chromium ions in water and serum samples.

Authors:  Xi Liu; Jun-Jian Xiang; Yong Tang; Xiao-Li Zhang; Qiang-Qiang Fu; Jun-Hui Zou; YueHe Lin
Journal:  Anal Chim Acta       Date:  2012-07-07       Impact factor: 6.558

5.  The need for non- or minimally-invasive biomonitoring strategies and the development of pharmacokinetic/pharmacodynamic models for quantification.

Authors:  Charles Timchalk; Thomas J Weber; Jordan N Smith
Journal:  Curr Opin Toxicol       Date:  2017-06

6.  Rapid visual genotyping method for germline mutants with small genomic fragment deletion by allele-specific PCR and lateral flow nucleic acid biosensor.

Authors:  Qiuju Su; Xiang Zhou; Tianwen Wu; Kui Li; Wentao Xu; Zhenyu Lin; Ping Shen; Bang Liu
Journal:  Mol Biol Rep       Date:  2021-10-26       Impact factor: 2.316

Review 7.  Updated values for molecular diagnosis for highly pathogenic avian influenza virus.

Authors:  Akira Sakurai; Futoshi Shibasaki
Journal:  Viruses       Date:  2012-08-07       Impact factor: 5.048

8.  A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid.

Authors:  Yijia Wang; Mohamed M A Zeinhom; Mingming Yang; Rongrong Sun; Shengfu Wang; Jordan N Smith; Charles Timchalk; Lei Li; Yuehe Lin; Dan Du
Journal:  Anal Chem       Date:  2017-08-21       Impact factor: 6.986

9.  A fast and sensitive quantitative lateral flow immunoassay for Cry1Ab based on a novel signal amplification conjugate.

Authors:  Chunxiang Chen; Jian Wu
Journal:  Sensors (Basel)       Date:  2012-08-27       Impact factor: 3.576

10.  Development of a novel fluorophore for real-time biomonitoring system.

Authors:  Hyun-Ok Song; Binna Lee; Ram Prasad Bhusal; Byounghun Park; Kyoungsik Yu; Chom-Kyu Chong; PyoYun Cho; Sung Yeon Kim; Hak Sung Kim; Hyun Park
Journal:  PLoS One       Date:  2012-11-02       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.