Literature DB >> 23110852

A collaborative framework for 3D alignment and classification of heterogeneous subvolumes in cryo-electron tomography.

Oleg Kuybeda1, Gabriel A Frank, Alberto Bartesaghi, Mario Borgnia, Sriram Subramaniam, Guillermo Sapiro.   

Abstract

The limitation of using low electron doses in non-destructive cryo-electron tomography of biological specimens can be partially offset via averaging of aligned and structurally homogeneous subsets present in tomograms. This type of sub-volume averaging is especially challenging when multiple species are present. Here, we tackle the problem of conformational separation and alignment with a "collaborative" approach designed to reduce the effect of the "curse of dimensionality" encountered in standard pair-wise comparisons. Our new approach is based on using the nuclear norm as a collaborative similarity measure for alignment of sub-volumes, and by exploiting the presence of symmetry early in the processing. We provide a strict validation of this method by analyzing mixtures of intact simian immunodeficiency viruses SIV mac239 and SIV CP-MAC. Electron microscopic images of these two virus preparations are indistinguishable except for subtle differences in conformation of the envelope glycoproteins displayed on the surface of each virus particle. By using the nuclear norm-based, collaborative alignment method presented here, we demonstrate that the genetic identity of each virus particle present in the mixture can be assigned based solely on the structural information derived from single envelope glycoproteins displayed on the virus surface. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23110852      PMCID: PMC3565063          DOI: 10.1016/j.jsb.2012.10.010

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  21 in total

1.  RASL: robust alignment by sparse and low-rank decomposition for linearly correlated images.

Authors:  Yigang Peng; Arvind Ganesh; John Wright; Wenli Xu; Yi Ma
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2012-11       Impact factor: 6.226

2.  3D reconstruction and processing of volumetric data in cryo-electron tomography.

Authors:  Hanspeter Winkler
Journal:  J Struct Biol       Date:  2006-08-11       Impact factor: 2.867

3.  Classification of cryo-electron sub-tomograms using constrained correlation.

Authors:  Friedrich Förster; Sabine Pruggnaller; Anja Seybert; Achilleas S Frangakis
Journal:  J Struct Biol       Date:  2007-07-26       Impact factor: 2.867

4.  Classification and 3D averaging with missing wedge correction in biological electron tomography.

Authors:  A Bartesaghi; P Sprechmann; J Liu; G Randall; G Sapiro; S Subramaniam
Journal:  J Struct Biol       Date:  2008-03-21       Impact factor: 2.867

5.  Classification of electron sub-tomograms with neural networks and its application to template-matching.

Authors:  Zhou Yu; Achilleas S Frangakis
Journal:  J Struct Biol       Date:  2011-03-05       Impact factor: 2.867

6.  High-throughput subtomogram alignment and classification by Fourier space constrained fast volumetric matching.

Authors:  Min Xu; Martin Beck; Frank Alber
Journal:  J Struct Biol       Date:  2012-03-07       Impact factor: 2.867

7.  Clustering and variance maps for cryo-electron tomography using wedge-masked differences.

Authors:  John M Heumann; Andreas Hoenger; David N Mastronarde
Journal:  J Struct Biol       Date:  2011-05-17       Impact factor: 2.867

8.  Averaging of electron subtomograms and random conical tilt reconstructions through likelihood optimization.

Authors:  Sjors H W Scheres; Roberto Melero; Mikel Valle; Jose-Maria Carazo
Journal:  Structure       Date:  2009-12-09       Impact factor: 5.006

9.  Methods for identifying and averaging variable molecular conformations in tomograms of actively contracting insect flight muscle.

Authors:  Shenping Wu; Jun Liu; Mary C Reedy; Hanspeter Winkler; Michael K Reedy; Kenneth A Taylor
Journal:  J Struct Biol       Date:  2009-08-19       Impact factor: 2.867

10.  Tomographic subvolume alignment and subvolume classification applied to myosin V and SIV envelope spikes.

Authors:  Hanspeter Winkler; Ping Zhu; Jun Liu; Feng Ye; Kenneth H Roux; Kenneth A Taylor
Journal:  J Struct Biol       Date:  2008-11-08       Impact factor: 2.867

View more
  14 in total

1.  Glutamate receptor desensitization is mediated by changes in quaternary structure of the ligand binding domain.

Authors:  David M Schauder; Oleg Kuybeda; Jinjin Zhang; Katherine Klymko; Alberto Bartesaghi; Mario J Borgnia; Mark L Mayer; Sriram Subramaniam
Journal:  Proc Natl Acad Sci U S A       Date:  2013-03-25       Impact factor: 11.205

2.  Mapping of Ebolavirus Neutralization by Monoclonal Antibodies in the ZMapp Cocktail Using Cryo-Electron Tomography and Studies of Cellular Entry.

Authors:  Erin E H Tran; Elizabeth A Nelson; Pranay Bonagiri; James A Simmons; Charles J Shoemaker; Connie S Schmaljohn; Gary P Kobinger; Larry Zeitlin; Sriram Subramaniam; Judith M White
Journal:  J Virol       Date:  2016-08-12       Impact factor: 5.103

3.  Gum-Net: Unsupervised Geometric Matching for Fast and Accurate 3D Subtomogram Image Alignment and Averaging.

Authors:  Xiangrui Zeng; Min Xu
Journal:  Proc IEEE Comput Soc Conf Comput Vis Pattern Recognit       Date:  2020-08-05

4.  Phantoms models to characterize influenza hemagglutinin-based vaccines.

Authors:  Dustin M McCraw; Audray K Harris
Journal:  Microsc Microanal       Date:  2017-08-04       Impact factor: 4.127

5.  Covariance Matrix Estimation for the Cryo-EM Heterogeneity Problem.

Authors:  E Katsevich; A Katsevich; A Singer
Journal:  SIAM J Imaging Sci       Date:  2015-01-22       Impact factor: 2.867

Review 6.  Electron Tomography: A Three-Dimensional Analytic Tool for Hard and Soft Materials Research.

Authors:  Peter Ercius; Osama Alaidi; Matthew J Rames; Gang Ren
Journal:  Adv Mater       Date:  2015-06-18       Impact factor: 30.849

7.  Practical workflow for cryo focused-ion-beam milling of tissues and cells for cryo-TEM tomography.

Authors:  Chyongere Hsieh; Thomas Schmelzer; Gregory Kishchenko; Terence Wagenknecht; Michael Marko
Journal:  J Struct Biol       Date:  2013-11-06       Impact factor: 2.867

8.  Protein secondary structure determination by constrained single-particle cryo-electron tomography.

Authors:  Alberto Bartesaghi; Federico Lecumberry; Guillermo Sapiro; Sriram Subramaniam
Journal:  Structure       Date:  2012-12-05       Impact factor: 5.006

Review 9.  HIV-1 envelope glycoprotein structure.

Authors:  Alan Merk; Sriram Subramaniam
Journal:  Curr Opin Struct Biol       Date:  2013-04-18       Impact factor: 6.809

10.  Structure and accessibility of HA trimers on intact 2009 H1N1 pandemic influenza virus to stem region-specific neutralizing antibodies.

Authors:  Audray K Harris; Joel R Meyerson; Yumiko Matsuoka; Oleg Kuybeda; Amy Moran; Donald Bliss; Suman R Das; Jonathan W Yewdell; Guillermo Sapiro; Kanta Subbarao; Sriram Subramaniam
Journal:  Proc Natl Acad Sci U S A       Date:  2013-03-04       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.