Literature DB >> 23107581

Descemet's stripping automated endothelial keratoplasty: three-year graft and endothelial cell survival compared with penetrating keratoplasty.

Marianne O Price1, Mark Gorovoy, Francis W Price, Beth A Benetz, Harry J Menegay, Jonathan H Lass.   

Abstract

PURPOSE: To assess 3-year outcomes of Descemet's stripping automated endothelial keratoplasty (DSAEK) in comparison with penetrating keratoplasty (PKP) from the Cornea Donor Study (CDS).
DESIGN: Prospective, multicenter, nonrandomized clinical trial. PARTICIPANTS: A total of 173 subjects undergoing DSAEK for a moderate risk condition (principally Fuchs' dystrophy or pseudophakic corneal edema) compared with 1101 subjects undergoing PKP from the CDS.
METHODS: The DSAEK procedures were performed by 2 experienced surgeons using the same donor and similar recipient criteria as for the CDS PKP procedures, performed by 68 surgeons. Graft success was assessed by Kaplan-Meier survival analysis. Central endothelial cell density (ECD) was determined from baseline donor and postoperative central endothelial images by the reading center used in the CDS Specular Microscopy Ancillary Study. MAIN OUTCOME MEASURES: Graft clarity and ECD.
RESULTS: The donor and recipient demographics were comparable in the DSAEK and PKP groups, except that the proportion of Fuchs' dystrophy cases was higher in the DSAEK cohort. The 3-year survival rate did not differ significantly between DSAEK and PKP procedures performed for either Fuchs' dystrophy (96% for both; P = 0.81) or non-Fuchs' cases (86% vs. 84%, respectively; P = 0.41). Principal causes of graft failure or regraft within 3 years after DSAEK and PKP were immunologic graft rejection (0.6% vs. 3.1%), endothelial decompensation in the absence of documented rejection (1.7% vs 2.1%), unsatisfactory visual or refractive outcome (1.7% vs. 0.5%), and infection (0% vs. 1.1%), respectively. The 3-year predicted probability of a rejection episode was 9% with DSAEK versus 20% with PKP (P = 0.0005). The median 3-year cell loss for DSAEK and PKP was 46% and 51%, respectively (P = 0.33), in Fuchs' dystrophy cases and 59% and 61%, respectively (P = 0.70), in the non-Fuchs' cases. At 3 years, use of a smaller DSAEK insertion incision was associated with significantly higher cell loss (60% vs. 33% for 3.2- and 5.0-mm incisions, respectively; P = 0.0007), but not with a significant difference in graft survival (P = 0.45).
CONCLUSIONS: The graft success rate and endothelial cell loss were comparable at 3 years for DSAEK and PKP procedures. A 5-mm DSAEK incision width was associated with significantly less cell loss than a 3.2-mm incision.
Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23107581      PMCID: PMC3562557          DOI: 10.1016/j.ophtha.2012.08.007

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  15 in total

1.  Effect of incision width on graft survival and endothelial cell loss after Descemet stripping automated endothelial keratoplasty.

Authors:  Marianne O Price; Maria Bidros; Mark Gorovoy; Francis W Price; Beth A Benetz; Harry J Menegay; Sara M Debanne; Jonathan H Lass
Journal:  Cornea       Date:  2010-05       Impact factor: 2.651

2.  Endothelial keratoplasty: the influence of insertion techniques and incision size on donor endothelial survival.

Authors:  Mark A Terry; Hisham A Saad; Neda Shamie; Edwin S Chen; Paul M Phillips; Daniel J Friend; Jeffrey D Holiman; Christopher Stoeger
Journal:  Cornea       Date:  2009-01       Impact factor: 2.651

3.  Specular microscopy ancillary study methods for donor endothelial cell density determination of Cornea Donor Study images.

Authors:  Beth Ann Benetz; Robin L Gal; Katrina J Ruedy; Carmella Rice; Roy W Beck; Andrea D Kalajian; Jonathan H Lass
Journal:  Curr Eye Res       Date:  2006-04       Impact factor: 2.424

4.  Effect of donor and recipient factors on corneal graft rejection.

Authors:  R Doyle Stulting; Alan Sugar; Roy Beck; Michael Belin; Mariya Dontchev; Robert S Feder; Robin L Gal; Edward J Holland; Craig Kollman; Mark J Mannis; Francis Price; Walter Stark; David D Verdier
Journal:  Cornea       Date:  2012-10       Impact factor: 2.651

5.  An evaluation of image quality and accuracy of eye bank measurement of donor cornea endothelial cell density in the Specular Microscopy Ancillary Study.

Authors:  Jonathan H Lass; Robin L Gal; Katrina J Ruedy; Beth Ann Benetz; Roy W Beck; Keith H Baratz; Edward J Holland; Andrea Kalajian; Craig Kollman; Francis J Manning; Mark J Mannis; Kristen McCoy; Monty Montoya; Doyle Stulting; Dongyuan Xing
Journal:  Ophthalmology       Date:  2005-03       Impact factor: 12.079

6.  Comparison of donor insertion techniques for descemet stripping automated endothelial keratoplasty.

Authors:  Jodhbir S Mehta; Yong Ming Por; Rebekah Poh; Roger W Beuerman; Donald Tan
Journal:  Arch Ophthalmol       Date:  2008-10

7.  The effect of donor age on corneal transplantation outcome results of the cornea donor study.

Authors:  Robin L gal; Mariya Dontchev; Roy W Beck; Mark J Mannis; Edward J Holland; Craig Kollman; Steven P Dunn; Ellen L Heck; Jonathan H Lass; Monty M Montoya; Robert L Schultze; R Doyle Stulting; Alan Sugar; Joel Sugar; Bradley Tennant; David D Verdier
Journal:  Ophthalmology       Date:  2008-04       Impact factor: 12.079

8.  Donor age and corneal endothelial cell loss 5 years after successful corneal transplantation. Specular microscopy ancillary study results.

Authors:  Jonathan H Lass; Robin L Gal; Mariya Dontchev; Roy W Beck; Craig Kollman; Steven P Dunn; Ellen Heck; Edward J Holland; Mark J Mannis; Monty M Montoya; Robert L Schultze; R Doyle Stulting; Alan Sugar; Joel Sugar; Bradley Tennant; David D Verdier
Journal:  Ophthalmology       Date:  2008-04       Impact factor: 12.079

9.  A modified technique for descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss.

Authors:  Massimo Busin; Priya R Bhatt; Vincenzo Scorcia
Journal:  Arch Ophthalmol       Date:  2008-08

10.  Descemet's stripping automated endothelial keratoplasty outcomes compared with penetrating keratoplasty from the Cornea Donor Study.

Authors:  Marianne O Price; Mark Gorovoy; Beth A Benetz; Francis W Price; Harry J Menegay; Sara M Debanne; Jonathan H Lass
Journal:  Ophthalmology       Date:  2010-01-19       Impact factor: 12.079

View more
  48 in total

1.  Comparison of outcomes and complications of deep anterior lamellar keratoplasty and penetrating keratoplasty performed in a large group of patients with keratoconus.

Authors:  Ashbala Khattak; Fouad R Nakhli; Khaled M Al-Arfaj; Abdullah A Cheema
Journal:  Int Ophthalmol       Date:  2017-05-22       Impact factor: 2.031

2.  Development of Selective Lamellar Keratoplasty within an Asian Corneal Transplant Program: The Singapore Corneal Transplant Study (An American Ophthalmological Society Thesis).

Authors:  Donald Tan; Marcus Ang; Anshu Arundhati; Wei-Boon Khor
Journal:  Trans Am Ophthalmol Soc       Date:  2015

3.  Graft decentering in DSAEK: a risk factor for immune reactions?

Authors:  T Lapp; S Heinzelmann; W A Shanab; T Reinhard; D Boehringer
Journal:  Eye (Lond)       Date:  2016-04-15       Impact factor: 3.775

4.  Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery.

Authors:  Alberto López-Miguel; María Sanchidrián; Itziar Fernández; Alfredo Holgueras; Miguel J Maldonado
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-11-22       Impact factor: 3.117

5.  Evolving Techniques in Corneal Transplantation.

Authors:  Grace E Boynton; Maria A Woodward
Journal:  Curr Surg Rep       Date:  2015-02-01

6.  [Perforating keratoplasty versus Descemet stripping automated endothelial keratoplasty in the partner eye: Functional results and patient satisfaction].

Authors:  N J Gross; D Böhringer; P Maier; T Reinhard
Journal:  Ophthalmologe       Date:  2015-10       Impact factor: 1.059

Review 7.  Descemet stripping endothelial keratoplasty--rapid recovery of visual acuity.

Authors:  Philip Maier; Thomas Reinhard; Claus Cursiefen
Journal:  Dtsch Arztebl Int       Date:  2013-05-24       Impact factor: 5.594

8.  Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet's stripping automated endothelial keratoplasty.

Authors:  Daisuke Tomida; Takefumi Yamaguchi; Akiko Ogawa; Yumiko Hirayama; Seika Shimazaki-Den; Yoshiyuki Satake; Jun Shimazaki
Journal:  Jpn J Ophthalmol       Date:  2015-06-02       Impact factor: 2.447

9.  Clinical results of non-Descemet stripping endothelial keratoplasty.

Authors:  Tao Zhang; Shao-Wei Li; Tie-Hong Chen; Jing-Liang He; Yan-Wei Kang; Fang-Qi Lyu; Jian-Hua Ning; Chang Liu
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

Review 10.  Indications, surgical procedures and outcomes of keratoplasty at a Tertiary University-based hospital: a review of 10 years' experience.

Authors:  Eman M Al-Sharif; Majed Alkharashi
Journal:  Int Ophthalmol       Date:  2021-02-24       Impact factor: 2.031

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.