Literature DB >> 23104660

The accuracy of CBCT in measuring jaws bone density.

M Cassetta1, L V Stefanelli, S Di Carlo, G Pompa, E Barbato.   

Abstract

BACKGROUND: The cone-beam computerized tomography (CBCT) has become widely used for oral and maxillofacial imaging, providing a good spatial resolution, gray density range, and contrast, as well as a good pixel/noise ratio. In the CBCT the dimensional accuracy is also comparable with Computer Tomography (CT), but in contrast to the CT, the gray density values of the CBCT images (voxel value [VV]) are not absolute. AIM: The aim of the study was to evaluate if there is a statistically significant difference in bone density values, defined as gray density values (VV), using two different CBCT exposure radiation (8 mAs or 15 mAs).
MATERIALS AND METHODS: 10 dry mandibles were CBCT scanned using two different exposure radiation (8 mAs or 15 mAs). Using software and a radiographic template, the CBCT-scan images were overlapped and two datasets were created, each one giving the respective gray values (VV), of the same area with the same spatial coordinates. The quantified gray density values of the planned volume were measured and expressed as VV in two different exposure radiation scans Groups (Group A: 8 mAs; Group B: 15 mAs). For the statistical analysis, t-test was used.
RESULTS: The differences between the CBCT gray density values (VV) of the Groups (Group A: 8 mAs; Group B: 15 mAs) were statistically significant (p <= .05).
CONCLUSIONS: This study demonstrated that the use of a CBCT to evaluate the bone density of jaws is not useful when the values are taken as absolute values. In spite of the lower radiation dose and costs of CBCT, this new technique does not allow an accurate assessment of bone density.

Mesh:

Year:  2012        PMID: 23104660

Source DB:  PubMed          Journal:  Eur Rev Med Pharmacol Sci        ISSN: 1128-3602            Impact factor:   3.507


  11 in total

Review 1.  CBCT-based bone quality assessment: are Hounsfield units applicable?

Authors:  R Pauwels; R Jacobs; S R Singer; M Mupparapu
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

2.  Variation in voxel value distribution and effect of time between exposures in six CBCT units.

Authors:  R Spin-Neto; E Gotfredsen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2014-02-03       Impact factor: 2.419

3.  Standardized method to quantify the variation in voxel value distribution in patient-simulated CBCT data sets.

Authors:  R Spin-Neto; E Gotfredsen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2014-10-29       Impact factor: 2.419

4.  Feasibility of CBCT in Diagnosing Otosclerosis by Measuring CBCT Bone Density: A Preliminary Study.

Authors:  Yalda Izadparast; Shoaleh Shahidi; Maryam Paknahad; Anis Moradi
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2021-03-26

5.  Radiographic observers' ability to recognize patient movement during cone beam CT.

Authors:  R Spin-Neto; L H Matzen; L Schropp; G S Liedke; E Gotfredsen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2014-02-26       Impact factor: 2.419

6.  Can gray values be converted to Hounsfield units? A systematic review.

Authors:  Marjorie Eguren; Anderson Holguin; Karla Diaz; Jose Vidalon; Carlos Linan; Camila Pacheco-Pereira; Manuel Oscar Lagravere Vich
Journal:  Dentomaxillofac Radiol       Date:  2021-06-19       Impact factor: 2.419

7.  Evaluation of alveolar cortical bone thickness and density for orthodontic mini-implant placement.

Authors:  Michele Cassetta; Aisha Aa Sofan; Federica Altieri; Ersilia Barbato
Journal:  J Clin Exp Dent       Date:  2013-12-01

8.  Osteoporosis prediction from the mandible using cone-beam computed tomography.

Authors:  Imad Barngkgei; Iyad Al Haffar; Razan Khattab
Journal:  Imaging Sci Dent       Date:  2014-11-25

9.  Accuracy of densitometry of two cone beam computed tomography equipment in comparison with computed tomography.

Authors:  Sina Haghanifar; Sajad Yousefi; Ehsan Moudi; Farida Abesi; Ali Bijani; Ali Akbar Moghadamnia; Mehrdad Nabahati
Journal:  Electron Physician       Date:  2017-05-25

10.  Efficacy of radiographic density values of the first and second cervical vertebrae recorded by CBCT technique to identify patients with osteoporosis and osteopenia.

Authors:  Farzad Esmaeli; Salar Payahoo; Majid Mobasseri; Masoome Johari; Javad Yazdani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.