Literature DB >> 36213485

Feasibility of CBCT in Diagnosing Otosclerosis by Measuring CBCT Bone Density: A Preliminary Study.

Yalda Izadparast1, Shoaleh Shahidi2, Maryam Paknahad3, Anis Moradi4.   

Abstract

The aim of this study was to measure cone beam computed tomography (CBCT) derived bone density of 6 anatomic points around the otic capsule in preoperative assessment of patients with clinically suspected otosclerosis, and to compare these densities with control group. CBCT images of 21 patients (34 ears, the otosclerosis group) with surgically confirmed otosclerosis and 26 patients (52 normal ears, the control group) were evaluated in this prospective study. Six regions of interest (ROI) were set manually around the otic capsule with the slice thickness of 0.3 mm. The mean CBCT bone density these regions were measured and compared in the case and control groups. In the case group, the mean CBCT bone density at the fissula ante fenestram (FAF) was significantly lower than the control group. Moreover, at the 4 points of the other ROIs (3-6) CBCT bone densities were significantly lower in the case group compared to the control group (p < 0.01). In this group, among 13 bilateral otosclerosis, 22 ears had conductive hearing loss (CHL), 4 ears had mixed hearing loss (MHL) and among 8 unilateral otosclerosis, 5 ears had CHL, 3 ears had MHL. Our study showed the mean CBCT bone density of ROIs 1 and 6 were correlated with the average air-bone gap in the bilateral and unilateral otosclerosis group, respectively. Quantitative evaluation of CBCT with a slice thickness of 0.3 mm can be used as a suitable tool for diagnosis and follow-up of otosclerosis in temporal bone. © Association of Otolaryngologists of India 2021.

Entities:  

Keywords:  Bone density; Cone-beam computed tomography; Otosclerosis

Year:  2021        PMID: 36213485      PMCID: PMC9535058          DOI: 10.1007/s12070-021-02502-2

Source DB:  PubMed          Journal:  Indian J Otolaryngol Head Neck Surg        ISSN: 2231-3796


  24 in total

1.  Deriving Hounsfield units using grey levels in cone beam computed tomography.

Authors:  P Mah; T E Reeves; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

2.  Reliability of voxel values from cone-beam computed tomography for dental use in evaluating bone mineral density.

Authors:  Yoshikazu Nomura; Hiroshi Watanabe; Eiichi Honda; Tohru Kurabayashi
Journal:  Clin Oral Implants Res       Date:  2010-05       Impact factor: 5.977

3.  Otosclerosis: anatomy and pathology in the temporal bone assessed by multi-slice and cone-beam CT.

Authors:  Ylva Dahlin Redfors; Hans Göran Gröndahl; Johan Hellgren; Ninita Lindfors; Inger Nilsson; Claes Möller
Journal:  Otol Neurotol       Date:  2012-08       Impact factor: 2.311

4.  Otosclerosis: incidence of positive findings on high-resolution computed tomography and their correlation to audiological test data.

Authors:  Ilka C Naumann; Beat Porcellini; Ugo Fisch
Journal:  Ann Otol Rhinol Laryngol       Date:  2005-09       Impact factor: 1.547

5.  Sexual Dimorphism of Maxillary Sinus Dimensions Using Cone-Beam Computed Tomography.

Authors:  Maryam Paknahad; Shoaleh Shahidi; Zahra Zarei
Journal:  J Forensic Sci       Date:  2016-11-16       Impact factor: 1.832

6.  Diagnostic value of cone-beam CT in histologically confirmed otosclerosis.

Authors:  Balázs Liktor; Péter Révész; Péter Csomor; Imre Gerlinger; István Sziklai; Tamás Karosi
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-09-19       Impact factor: 2.503

7.  Histologic changes on stapedial footplate in otosclerosis. Correlations between histologic activity and clinical findings.

Authors:  Anton Gros; Jagoda Vatovec; Maja Sereg-Bahar
Journal:  Otol Neurotol       Date:  2003-01       Impact factor: 2.311

8.  Correlation of CT analysis and audiometry in Japanese otosclerosis.

Authors:  Kensuke Kiyomizu; Tetsuya Tono; Dewen Yang; Atsushi Haruta; Takao Kodama; Shizuo Komune
Journal:  Auris Nasus Larynx       Date:  2004-06       Impact factor: 1.863

9.  A cone beam computed tomographic evaluation of the size of the sella turcica in patients with cleft lip and palate.

Authors:  Maryam Paknahad; Shoaleh Shahidi; Iman Khaleghi
Journal:  J Orthod       Date:  2017-07-04

10.  Accuracy of densitometry of two cone beam computed tomography equipment in comparison with computed tomography.

Authors:  Sina Haghanifar; Sajad Yousefi; Ehsan Moudi; Farida Abesi; Ali Bijani; Ali Akbar Moghadamnia; Mehrdad Nabahati
Journal:  Electron Physician       Date:  2017-05-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.